Eaton S48N12S02 General-Purpose Transformer - UL Listed

Part Number: S48N12S02
Manufacturer
Eaton
Part number
S48N12S02

Quick Summary

S48N12S02 is a general-purpose encapsulated transformer designed to provide 480 V to 120 V control power for industrial panels and equipment. Engineers often face space constraints, environmental exposure, and lengthy installation cycles; this unit delivers a compact footprint and rugged enclosure to simplify commissioning. UL Listed certification and a NEMA 3R enclosure support safe outdoor operation and reliable performance in challenging environments. The 60 Hz, single-phase design with a 2 kVA rating and aluminum coil helps reduce energy losses and maintenance costs. In practice, this transformer accelerates panel builds, meets regulatory requirements, and lowers total cost of ownership for power distribution projects.

Product Information

Extended Description

S48N12S02 Eaton: Eaton General purpose encapsulated transformer, EP, aluminum, NEMA 3R, 68, 60 Hz, single-phase, 480 V, 120 V, NONE, 115 °C rise, 2 KVA, indoor-outdoor, 511C
Product Name
Eaton General purpose encapsulated transformer
Catalog Number
S48N12S02
UPC
786680062919
Product Length/Depth
6.52 in
Product Height
13.41 in
Product Width
6.37 in
Product Weight
49 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Coil material
Aluminum
Design
EP
Enclosure
NEMA 3R
Frame
68
Tap size
None
Type
General-Purpose Encapsulated Transformer
Wiring connection
511C
Frequency rating
60 Hz
Phase
Single-phase
Primary voltage
480 V
Secondary Voltage
120 V
Temperature rise
115 °C rise
Volt ampere rating
2 kVA
Weathershield
Indoor-Outdoor
Encapsulated EP construction with an aluminum coil delivers superior heat management and corrosion resistance. This translates to longer service life in harsh factories and reduced maintenance cycles, lowering lifecycle costs. Ideal for control panels and motor starter assemblies in environments where dust, moisture, or vibration is common. Weather-resilient NEMA 3R enclosure with a compact 6.52 in L × 6.37 in W × 13.41 in H footprint reduces cabinet footprint and simplifies mounting. The rugged housing keeps moisture and contaminants at bay while maintaining consistent performance. This addresses installation challenges in outdoor enclosures and crowded panel spaces. 2 kVA rating with 480 V primary and 120 V secondary delivers stable control power for PLCs, relays, and sensing circuits. The 60 Hz single-phase design aligns with common North American equipment, reducing integration risk. This configuration supports reliable operation across conveyor systems and automated lines. 115 °C rise rating informs thermal performance under full load, helping specify a safe operating margin. UL Listed certification confirms adherence to electrical safety standards, streamlining procurement and audit processes. Together, these factors minimize project delays and ensure consistent performance in production environments. Weight of 49 lb and a 68-frame design provide confidence in handling during installation and replacement. The wiring connection 511C and standard dimensioning support straightforward wiring and field serviceability. This helps maintainers conduct quick swaps with minimal downtime. Warranty coverage includes a one-year limited warranty from installation or eighteen months from shipment, reducing risk for system upgrades and new line deployments.

Get a Quick Quote for a Eaton S48N12S02

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton S48N12S02? Enquire Now

FAQs

Install the S48N12S02 in a compatible enclosure or cabinet with a NEMA 3R rating to protect against weather. Use the 511C wiring connection for field wiring, mount within the 6.52 in L × 6.37 in W × 13.41 in H footprint, and connect 480 V primary to the supply and 120 V secondary to the load. Ensure proper torque on connections and verify 60 Hz input specification.
Key specs include 2 kVA volt-ampere rating, 480 V primary voltage, 120 V secondary voltage, 60 Hz frequency, single-phase configuration, aluminum coil, and a 115 °C rise. It uses wiring connection 511C and has a 68-frame design, with a UL Listed certification for safety compliance.
Yes. It features a NEMA 3R enclosure suitable for indoor-outdoor installations and UL Listed safety certification, enabling dependable operation in factory floors, outdoor cabinets, and damp environments while meeting typical industrial codes.
The transformer is UL Listed and designed with a NEMA 3R enclosure for outdoor use. Its 60 Hz single-phase operation and aluminum coil construction are standard for North American industrial power distribution equipment, providing regulatory alignment and reliability.
With a 2 kVA rating and robust encapsulated construction, the unit minimizes downtime and replacement frequency in busy lines. The 49 lb weight and compact footprint simplify installation and service, while UL listing and a 1-year warranty (or 18 months from shipment) provide predictable support and lower total cost of ownership.