Eaton S60G11S01N General-Purpose Transformer - UL Listed
Part Number: S60G11S01N
Quick Summary
Eaton S60G11S01N General-Purpose Transformer delivers reliable power isolation for control panels and small industrial equipment. Manufacturers often struggle with panel reliability, exposure to dust and moisture, and voltage fluctuations that hamper uptime. UL Listed and a NEMA 3R enclosure support safe, durable operation in indoor-outdoor settings. With aluminum coil design, 2 at -5% FCBN tap options, and a compact 1 kVA footprint, it offers quick installation and stable power for automation systems, motor starters, and control circuits. This transformer is well-suited for machines with 600 V primary and 120/240 V secondary needs, delivering consistent output while reducing maintenance and lifecycle costs.
Product Information
Extended Description
S60G11S01N Eaton: Eaton General purpose encapsulated transformer, EP, aluminum, NEMA 3R, 59A, 60 Hz, single-phase, 600 V, 120/240 V, 2 at -5% FCBN, 115 °C rise, 1 KVA, indoor-outdoor, 2I
Product Name
Eaton General purpose encapsulated transformer
Catalog Number
S60G11S01N
UPC
786680101618
Product Length/Depth
5.75 in
Product Height
11.28 in
Product Width
5.99 in
Product Weight
28 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Model N
Coil material
Aluminum
Design
EP
Enclosure
NEMA 3R
Frame
59A
Tap size
2 at -5% FCBN
Type
General-Purpose Encapsulated Transformer
Wiring connection
2I
Frequency rating
60 Hz
Phase
Single-phase
Primary voltage
600 V
Secondary Voltage
120/240 V
Temperature rise
115 °C rise
Volt ampere rating
1 kVA
Weathershield
Indoor-Outdoor
Encapsulated construction with an aluminum coil protects windings from moisture and contaminants, improving insulation life and reliability. This feature reduces field failures and maintenance costs, especially in harsh environments common to industrial automation. It is well-suited for control panels, motor starters, and machine builders that require dependable power isolation in tight spaces. NEMA 3R enclosure and Weathershield capability enable indoor-outdoor installation without additional enclosures, lowering installation time and total cost of ownership. The durable enclosure also supports compliance with outdoor service requirements in manufacturing plants and utility installations. Applications include outdoor control stations and equipment cabinets where weather resistance matters. Voltage taps with 2 at -5% FCBN provide voltage compensation for line fluctuations, reducing nuisance tripping and equipment wear. This capability translates to more stable control signals and longer life for connected devices in variable electrical environments. Ideal for facilities with long runs, fluctuating utility feeds, or remote panels requiring voltage adjustment. Compact footprint (5.75 in depth, 5.99 in width, 11.28 in height) and 1 kVA rating offer easy integration into panel layouts and limited space setups. The single-phase, 60 Hz design aligns with common plant electrical systems and simplifies replacement in legacy installations. This compatibility minimizes downtime during upgrades and avoids costly rework. Warranty and compliance: One-year Eaton warranty (or 18 months from shipment) provides assurance for procurement teams, while UL Listed certification supports safety compliance in electrical installations. These factors translate into a lower risk, faster ROI for automation projects.
Get a Quick Quote for a Eaton S60G11S01N
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton S60G11S01N?
Enquire Now
FAQs
For panel installations, confirm compatibility with a NEMA 3R enclosure and ensure sufficient clearance for cooling and wiring. Use the 2I wiring connection scheme and account for a 600 V primary rating plus 120/240 V secondary outputs. The encapsulated aluminum winding provides insulation margins that support service in mixed indoor-outdoor environments, helping minimize field adjustments after commissioning.
Key specs include a 1 kVA rating, single-phase 60 Hz operation, 600 V primary, and 120/240 V secondary. It features 2 taps at -5% FCBN to compensate voltage drop, a 115 °C rise rating, and an indoor-outdoor Weathershield with a NEMA 3R enclosure, making it suitable for versatile automation applications.
Yes. The S60G11S01N is designed for indoor-outdoor use with a NEMA 3R enclosure and Weathershield capability, plus UL Listed safety certification. This combination provides durability against dust, moisture, and temperature swings typical in outdoor control stations and plant installations.
The transformer is UL Listed, signaling compliance with recognized safety standards for electrical equipment. Its NEMA 3R enclosure further ensures durable outdoor performance. Together, these certifications reduce procurement risk, simplify compliance audits, and support safer, more reliable installations in industrial settings.
The encapsulated aluminum-wound design enhances insulation life and reduces maintenance needs, while the rugged enclosure lowers field fault risk. With a 1 kVA rating and a 600 V/120/240 V specification set, it supports reliable power delivery for automation systems, contributing to lower downtime and faster project ROI. A one-year warranty (or 18 months from shipment) adds procurement confidence.