Eaton S65N11S02XCE Transformer - UL Listed 2 kVA
Part Number: S65N11S02XCE
Quick Summary
The Eaton S65N11S02XCE encapsulated transformer provides reliable voltage isolation for control panels and industrial equipment. Many engineers struggle with heat buildup and enclosure exposure that threaten reliability in demanding environments. UL Listed and CE Marked, with a NEMA 3R enclosure option, support safe, compliant installations in diverse conditions. With a 2 kVA rating, indoor-outdoor use, and aluminum coil, it delivers a compact, durable solution that reduces lifecycle costs and simplifies panel design. Compatible with 208V, 240V, 400V, and 480V primaries and 120/240V secondary, it integrates smoothly with existing electrical architectures and minimizes voltage mismatches during upgrades. Its 50/60 Hz operation ensures compatibility across regional electrical systems, reducing the need for multiple SKUs.
Product Information
Extended Description
S65N11S02XCE Eaton: Eaton General purpose encapsulated transformer, EP, aluminum, NEMA 3R, 176, 50-60 Hz, single-phase, 208 V, 240 V, 400 V, 480 V, 120/240 V, NONE, 115 °C rise, 2 KVA, indoor-outdoor, 160A
Product Name
Eaton General purpose encapsulated transformer
Catalog Number
S65N11S02XCE
UPC
786680079290
Product Length/Depth
6.52 in
Product Height
13.41 in
Product Width
6.37 in
Product Weight
70 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
50/60 Hz, CE Marked
Coil material
Aluminum
Design
EP
Enclosure
NEMA 3R
Frame
176
Tap size
None
Type
General-Purpose Encapsulated Transformer
Wiring connection
160A
Frequency rating
50-60 Hz
Phase
Single-phase
Primary voltage
208 V, 240 V, 400 V, 480 V
Secondary Voltage
120/240 V
Temperature rise
115 °C rise
Volt ampere rating
2 kVA
Weathershield
Indoor-Outdoor
Feature: General-purpose encapsulated EP design provides rugged protection in harsh environments. Business Impact: Improves reliability and reduces panel maintenance costs over time. Application: Ideal for control panels in manufacturing lines and process automation where space is at a premium. Feature: Flexible primary and secondary voltages—208/240/400/480 V to 120/240 V—with a 2 kVA rating. Business Impact: Cuts SKU proliferation and supports multi-volt installations, lowering procurement complexity. Application: Suitable for mixed-voltage facilities undergoing expansion or modernization. Feature: NEMA 3R indoor-outdoor enclosure with corrosion-resistant aluminum windings. Business Impact: Enables outdoor or semi-exposed installations without added enclosure upgrades, reducing cooling and weatherproofing costs. Application: Outdoor control cabinets, machine rooms adjacent to outdoor equipment, and exposed process lines. Feature: Single-phase operation at 50-60 Hz with a 176 frame and 70 lb weight. Business Impact: Simplifies installation, wiring, and retrofits, while maintaining compatibility with common industrial power systems. Application: Quick integration in existing single-phase power layouts across varied geographies. Feature: 2 kVA VA rating and 115 °C rise with 160A wiring connection. Business Impact: Delivers reliable load handling with manageable heat, enabling predictable performance and easier fault diagnostics. Application: Panel upgrades and new builds where predictable transformer loading is critical. These features collectively offer a robust balance of performance, installation ease, and compliance for industrial transformers used in power management and distribution.
Get a Quick Quote for a Eaton S65N11S02XCE
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton S65N11S02XCE?
Enquire Now
FAQs
To install, mount the 176 frame transformer in a compliant enclosure and connect the primary to 208/240/400/480 V as required, ensuring proper clearance and grounding. Wire the 120/240 V secondary to the load, observing the 160A wiring connection rating. The unit requires no taps (None), and the enclosure supports indoor-outdoor use in a NEMA 3R environment. Always verify UL Listed and CE Marked compliance during commissioning.
The S65N11S02XCE accepts 208, 240, 400, and 480 V primaries and provides a 120/240 V secondary, all in a single-phase, 50-60 Hz design. The 2 kVA rating supports common control loads, reducing SKU proliferation while maintaining safe isolation and compatible performance across regional power systems.
Yes. It features a NEMA 3R enclosure and indoor-outdoor weather resistance, with aluminum windings that resist corrosion. This combination enables reliable operation in outdoor cabinets or semi-exposed installations, minimizing extra enclosure or protection costs and simplifying installation in harsh environments.
The transformer is UL Listed and CE Marked, confirming compliance with recognized safety and performance standards. The enclosure supports outdoor-ready installation (NEMA 3R), and the unit is designed for 50/60 Hz operation across regional electrical systems, reducing compliance risk during worldwide deployments.
Expect low maintenance due to rugged encapsulation and a robust single-phase design. The 2 kVA rating supports stable loads with predictable heat limits, while the aluminum windings reduce weight and simplify handling. A reliable, UL-listed/CE-marked transformer shortens downtime during upgrades and improves lifecycle cost of ownership for power management in automation systems.