Eaton SPD080400Y3A Surge Protection Device - UL 1449 Listed

Part Number: SPD080400Y3A
Manufacturer
Eaton
Part number
SPD080400Y3A

Quick Summary

The Eaton SPD080400Y3A surge protection device delivers reliable transient suppression for 400Y/230V, 3‑phase panels in industrial environments. Engineers often battle nuisance tripping and unplanned downtime when surges bite, threatening sensitive drives and control systems. UL 1449 Listed, meets IBC 2006, CBC 2007, and UBC Zone 4, with EMI/RFI filtering and an audible alarm to clearly signal faults. Designed for direct bus mounted panel boards and easy integration, it helps protect downstream equipment while simplifying maintenance planning and compliance across industrial protection strategies.

Product Information

Extended Description

SPD080400Y3A Eaton: Eaton Surge Protection Device, SPD Series, 80 kA per phase, 400Y/230V (4W+G) rating, 320 L-N, 320 L-G, 320 N-G, 640 L-L MCOV, Internal integrated, and surge counter, used with Direct bus mounted panel boards (PRL1a, 2a, 3a, 3e)
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD080400Y3A
UPC
786685317229
Product Length/Depth
9.5 in
Product Height
3.45 in
Product Width
5.4 in
Product Weight
3.5 lb
Warranty
15 year
Certifications
UL 1449 UL Listed
Type
SPD
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package and surge counter
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
320 L-N, 320 L-G, 320 N-G, 640 L-L
Used with
Direct bus mounted panelboards (PRL1a, 2a, 3a, 3e)
Voltage rating
400Y/230V (4W+G)
Surge current
80 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
Feature → Business Impact → Application: High surge current rating of 80 kA per phase provides robust transient suppression, reducing equipment wear and preventing nuisance outages in critical control panels. This translates to lower maintenance costs and extended equipment life in manufacturing lines and process facilities. Application: direct bus mounted panel boards PRL1a, 2a, 3a, 3e, enabling streamlined installation in new builds or retrofit projects. Feature → EMI/RFI filtering up to 50 dB from 10 kHz to 100 MHz reduces electrical noise, improving PLC performance andElectro-Magnetic compatibility in sensitive automation networks. This supports stricter EMC compliance and smoother operations in high‑noise environments. Feature → Audible alarm with silence button and surge counter with rest button provides real-time fault signaling and traceable events, enabling faster root-cause analysis and uptime gains. Application: critical protection in machine control systems and panel boards. Feature → Form C relay contact and internal integrated design streamline wiring and reduce panel depth, delivering faster installations and easier service accessibility. Application: compact, space‑efficient protection in compact control panels. Feature → 50/60 Hz compatibility, nominal discharge current of 20 kA and 200 kAIC short-circuit rating deliver dependable protection for mixed voltage networks and high‑inrush equipment, supporting reliable operation across diverse facilities. Application: data centers, packaging lines, and HVAC control systems. Feature → 320 L-N, 320 L-G, 320 N-G, 640 L-L operating voltages with a 400Y/230V rating ensure compatibility with standard industrial power systems, simplifying specification and procurement processes. Application: new installations and retrofits in industrial facilities. Feature → 3.5 lb weight, 9.5 in length, 5.4 in width and 3.45 in height, along with 15-year warranty, provide long-term value, predictable lifecycle costs, and easier maintenance planning. Application: equipment rooms and panel assemblies where space and service intervals are critical. Feature → Internal integrated mounting simplifies installation and reduces auxiliary hardware needs, delivering faster deployment in retrofit projects and new builds. Application: panelboard upgrades and factory automation upgrades with minimal disruption.

Get a Quick Quote for a Eaton SPD080400Y3A

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton SPD080400Y3A? Enquire Now

FAQs

Yes. SPD080400Y3A is designed for Direct bus mounted panel boards PRL1a, 2a, 3a, and 3e, enabling straightforward integration with existing Eaton bus‑mounted architectures and reducing installation time.
SPD080400Y3A delivers 80 kA per phase surge current with a 200 kAIC short‑circuit rating, and a nominal discharge current of 20 kA, providing robust protection for 400Y/230V systems.
The device is UL 1449 Listed, with UL safety listing, and it meets building‑code related expectations such as IBC 2006, CBC 2007, and UBC Zone 4, supporting compliance in industrial facilities.
The unit includes EMI/RFI filtering, an audible fault alarm, a surge counter with rest button, and a Form C relay contact, all of which enable quick fault detection, improved EMC performance, and faster maintenance response.
Dimensions are 9.5 in L, 5.4 in W, 3.45 in H, with a weight of 3.5 lb. It supports internal integrated mounting for streamlined installation in compact control panels.