Eaton SPD080480Y2C Surge Protection Device - UL 1449 Listed

Part Number: SPD080480Y2C
Manufacturer
Eaton
Part number
SPD080480Y2C

Quick Summary

Eaton SPD080480Y2C surge protection device protects switchboards and panelboards from voltage transients in 480Y/277V systems. When installations face unpredictable surges, nuisance trips and diagnostics delays hinder uptime, and visibility into events is limited. Key certification includes UL 1449 Listed status, underscoring compliance with surge protection safety standards; EMI/RFI filtering provides up to 50 dB attenuation from 10 kHz to 100 MHz for cleaner power and fewer interference issues. With internal integrated mounting and 50/60 Hz compatibility, it delivers a compact, plug‑and‑play protection solution for switchboards, busways, and panelboards PRL1a through 4. A 15‑year warranty, robust surge ratings, and clear event monitoring translate into lower lifecycle costs and more reliable electrical protection for industrial facilities.

Product Information

Extended Description

SPD080480Y2C Eaton: Eaton Surge Protection Device, SPD Series, 80 kA per phase, 480Y/277V (4W+G) rating, 320 L-N, 320 L-G, 320 N-G, 640 L-L MCOV, Internal integrated, , used with Switchboard, busways, and panel boards (PRL1a, 2a, 3a, 3e, 4)
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD080480Y2C
UPC
786685321592
Product Length/Depth
9.5 in
Product Height
3.45 in
Product Width
5.4 in
Product Weight
3.5 lb
Warranty
15 year
Certifications
UL 1449 UL Listed
Type
SPD
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
320 L-N, 320 L-G, 320 N-G, 640 L-L
Used with
Switchboard, busways, and panelboards (PRL1a, 2a, 3a, 3e, 4)
Voltage rating
277/480 wye (4W+G)
Surge current
80 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
SPD080480Y2C delivers 80 kA per phase surge current rating, enabling protection against high-energy transients that can damage drives, controllers, or switchgear. This capability reduces unplanned downtime and extends equipment life for motors and power distribution units in industrial facilities. It is designed for 480Y/277V four‑wire systems with a ground (4W+G), making it ideal for switchboards, busways, and panelboards PRL1a–4. With a nominal discharge current of 20 kA and a 200 kA short‑circuit rating, this SPD offers robust protection for downstream equipment during severe surge events while maintaining safe operation across 320 L‑N, 320 L‑G, 320 N‑G, and 640 L‑L configurations. EMI/RFI filtering provides up to 50 dB of noise attenuation from 10 kHz to 100 MHz, improving control reliability and reducing interference in sensitive electronics. An audible alarm with silence button, Form C relay contact, and a surge counter with rest button give operators clear visibility and easy integration with plant monitoring systems. Internal integrated mounting simplifies installation in crowded panels; its compact footprint (9.5 in L × 5.4 in W × 3.45 in H) and 3.5 lb weight support quick deployment in existing Eaton architectures. The unit operates from -40 to 50 °C and comes with a 15-year warranty for long-term protection of switchgear, busways, and panelboards (PRL1a, 2a, 3a, 3e, 4).

Get a Quick Quote for a Eaton SPD080480Y2C

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton SPD080480Y2C? Enquire Now

FAQs

Install the SPD080480Y2C using its internal integrated mounting within an Eaton-compatible enclosure or panelboard. Ensure proper alignment with 4W+G configurations, connect line and ground conductors per the stated voltage ratings (277/480 V), and route the wiring to minimize interference. Verify clearance and refer to the Eaton specification sheet for wiring diagrams and terminal assignments. The compact dimensions (9.5 in L × 5.4 in W × 3.45 in H) aid fitment in crowded spaces, while the Form C relay output can be wired to plant PLCs or annunciator panels for status monitoring.
SPD080480Y2C provides 80 kA per phase surge current, a nominal discharge current of 20 kA, and a 200 kA short-circuit rating. It operates at 50/60 Hz with voltage ratings of 277/480 V and supports path configurations of 320 L‑N, 320 L‑G, 320 N‑G, and 640 L‑L. These specs enable robust protection for critical loads in industrial panelboards, switchboards, and busways against high-energy transients while maintaining uptime and equipment integrity.
Yes. The SPD080480Y2C is designed for use with switchboards, busways, and panelboards (PRL1a, 2a, 3a, 3e, 4) and supports -40 to 50 °C operation, making it suitable for a range of industrial environments. Its UL 1449 Listed certification confirms safety compliance, and EMI/RFI filtering helps maintain control system reliability in electrically noisy facilities. The 15-year warranty further reinforces long-term protection in demanding installations.
SPD080480Y2C carries UL 1449 Listed certification, indicating compliance with recognized surge protection safety standards. This certification matters because it provides verifiable safety and performance benchmarks for protecting electrical infrastructure. For integrators and end users, UL listing simplifies procurement, qualification, and warranty considerations, ensuring the device meets industry safety expectations for industrial power protection.
The unit includes an audible alarm with a silence button, a Form C relay contact for signaling, and a surge counter with a rest button, enabling straightforward diagnostic workflows and remote monitoring integration. These features help operators detect and respond to surge events quickly, improving uptime and reducing the risk of cascading failures in critical power systems. The 15-year warranty also contributes to favorable total cost of ownership.