Eaton SPD080480Y3A Surge Protection Device - UL Listed

Part Number: SPD080480Y3A
Manufacturer
Eaton
Part number
SPD080480Y3A

Quick Summary

SPD080480Y3A surge protection device protects electrical systems from transient surges in 480Y/277V distributed power. Facilities teams often battle nuisance tripping and data gaps that complicate preventive maintenance and increase downtime costs. This Eaton device delivers robust UL 1449 Listed protection, EMI/RFI filtering with up to 50 dB attenuation, an audible alarm with silence button, and a built-in surge counter for proactive event tracking. Designed for internal mounting on Direct bus mounted panel boards such as PRL1a, 2a, 3a, and 3e, it minimizes panel intrusion and simplifies wiring. A 15-year warranty, a wide operating temperature range (-40 to 50 °C), and a compact footprint combine to boost reliability while supporting scalable protection across industrial facilities.

Product Information

Extended Description

SPD080480Y3A Eaton: Eaton Surge Protection Device, SPD Series, 80 kA per phase, 480Y/277V (4W+G) rating, 320 L-N, 320 L-G, 320 N-G, 640 L-L MCOV, Internal integrated, and surge counter, used with Direct bus mounted panel boards (PRL1a, 2a, 3a, 3e)
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD080480Y3A
UPC
786685317199
Product Length/Depth
9.5 in
Product Height
3.45 in
Product Width
5.4 in
Product Weight
3.5 lb
Warranty
15 year
Certifications
UL 1449 UL Listed
Type
SPD
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package and surge counter
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
320 L-N, 320 L-G, 320 N-G, 640 L-L
Used with
Direct bus mounted panelboards (PRL1a, 2a, 3a, 3e)
Voltage rating
277/480 wye (4W+G)
Surge current
80 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
High-energy protection translates to reduced downtime and lower replacement costs; with 80 kA per phase and a 200 kAIC short-circuit rating, equipment stays safeguarded during severe surge events, enabling uninterrupted production. This translates to measurable reliability gains and longer service life for connected loads in demanding industrial environments, including direct bus mounted panel boards PRL1a, 2a, 3a, and 3e. Integrated audible alarms with a silence button provide immediate fault visibility to operators, while the surge counter enables traceability for maintenance planning and compliance reporting. EMI/RFI filtering delivering up to 50 dB attenuation from 10 kHz to 100 MHz reduces noise on control signals, improving PLC and drive performance in noisy factory floors. The internal mounting design saves space, simplifies wiring, and reduces installation time, helping projects stay on schedule and within budget. Compatibility with 50/60 Hz systems and a 277/480 V rating supports widespread industrial deployment with minimal reconfiguration. The 15-year warranty adds long-term cost certainty, while UL 1449 Listed certification reinforces safety compliance. Direct bus mounting and compact dimensions provide asset-light installation for modernized facilities seeking scalable surge protection.

Get a Quick Quote for a Eaton SPD080480Y3A

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton SPD080480Y3A? Enquire Now

FAQs

SPD080480Y3A is designed for internal mounting inside direct bus mounted panel boards such as PRL1a, 2a, 3a, and 3e. Installation steps include powering down the panel, mounting the unit within the board enclosure, connecting L-N, L-G, and N-G per the wiring diagram, wiring the internal alarm and surge counter, and performing a functional test to verify UL 1449 Listed protection and proper operation of the audible alarm.
Key specs include 80 kA per phase surge capacity, 200 kAIC short-circuit rating, nominal discharge current of 20 kA, and operating at 50/60 Hz with a voltage rating of 277/480 V (4W+G). It provides 320 V line-to-neutral, line-to-ground, and line-to-ground voltages, 640 V MCOV, and operates from -40 to 50 °C. It is UL 1449 Listed and includes a surge counter and audible alarm.
Yes, SPD080480Y3A is designed for 480Y/277V systems and is intended for direct bus mounted panel boards. It features internal integrated mounting for space efficiency and is compatible with PRL1a, 2a, 3a, and 3e configurations. Its compact dimensions (9.5 in L, 3.45 in H, 5.4 in W) and 3.5 lb weight simplify installation in tight panel spaces.
The device is UL 1449 Listed, providing recognized electrical safety and performance standards compliance. It meets industry safety expectations for surge protection devices used in commercial and industrial applications and is designed to integrate with IBC 2006, CBC 2007, and UBC Zone 4 installation guidelines to support safe, code-compliant installations.
The 15-year warranty reduces lifecycle risk and maintenance costs by ensuring long-term protection with minimal replacement. Combined with an audible alarm, surge counter, and EMI/RFI filtering, the unit lowers downtime from surge events and improves system reliability, leading to fewer unplanned outages and a faster path to return on investment in mission-critical equipment.