Eaton SPD080600D2B Surge Protection Device - UL 1449 Listed

Part Number: SPD080600D2B
Manufacturer
Eaton
Part number
SPD080600D2B

Quick Summary

SPD080600D2B is a surge protection device that guards switchgear against transient overvoltages in industrial environments. Engineers often face nuisance trips and equipment damage from unpredictable transients, leading to unplanned downtime and maintenance costs. This model carries UL 1449 Listed certification and meets or exceeds key building standards, including IBC 2006, CBC 2007, and UBC Zone 4, underscoring reliability in harsh environments. With EMI/RFI filtering and a remote-display compatible design, it also supports streamlined monitoring and faster fault isolation, delivering measurable business value through improved uptime, safer operation, and reduced total cost of ownership. The product is positioned to complement protective schemes that require precise coordination with switchgear and protection instrumentation.

Product Information

Extended Description

SPD080600D2B Eaton: Eaton Surge Protection Device, SPD Series, 80 kA per phase, 600V delta (4W+G) rating, 840 L-G, 840 L-L MCOV, Internal integrated, Standard feature package, used with Switchgear with remote display
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD080600D2B
UPC
786685318905
Product Length/Depth
9.5 in
Product Height
3.45 in
Product Width
5.4 in
Product Weight
3.5 lb
Warranty
15 year
Certifications
UL 1449 UL Listed
Type
SPD
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
840 L-G, 840 L-L
Used with
Switchgear with remote display
Voltage rating
600 delta (4W+G)
Surge current
80 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
Feature: 80 kA per phase surge capability and 600V delta rating. Business impact: Robust protection for critical switchgear combinations reduces transient damage and unplanned outages. Application: Ideal for 4W+G configurations in industrial plants, especially where high-energy surges are common. The system remains within safe operating margins, enabling reliable uptime. Long-tail keywords: 80 kA per phase surge, 600 V delta protection, transformerless protection devices. Feature: 840 V L-G and 840 V L-L MCOV with 50/60 Hz compatibility. Business impact: Broad electrical compatibility simplifies integration with existing power architecture while maintaining protection performance. Application: Suitable for mixed-load facilities and equipment banks that require consistent MCOV. Long-tail keywords: MCOV 840, 50/60 Hz protection, mixed-load industrial environments. Feature: EMI/RFI filtering up to 50 dB from 10 kHz to 100 MHz. Business impact: Noise attenuation improves downstream sensor accuracy and control stability, reducing misreads and downtime. Application: Essential in control rooms and environments with sensitive instrumentation. Long-tail keywords: EMI/RFI filtering 50 dB, noise attenuation, control stability. Feature: Audible alarm with silence button and Form C relay contact. Business impact: Immediate audible/visual status signaling plus programmable signaling to plant controllers, accelerating fault triage. Application: Integrates with remote display-enabled switchgear for real-time protection status. Long-tail keywords: audible alarm, Form C relay, status signaling. Feature: Internal integrated mounting and compact footprint (9.5 in L x 5.4 in W x 3.45 in H, 3.5 lb). Business impact: Easy retrofits and space-efficient protection without extensive chassis modifications. Application: Works within crowded switchgear bays and modular equipment racks. Long-tail keywords: compact surge protector, internal mounting, space-saving design. Feature: 15-year warranty and UL 1449 Listed certification. Business impact: Tangible lifetime protection with certified reliability, lowering replacement and maintenance risk. Application: High-value reliability for mission-critical systems. Long-tail keywords: UL 1449 Listed, warranty 15 year, reliable protection.

Get a Quick Quote for a Eaton SPD080600D2B

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton SPD080600D2B? Enquire Now

FAQs

SPD080600D2B features internal integrated mounting and a footprint of 9.5 in L x 5.4 in W x 3.45 in H, designed to fit compact switchgear bays. It operates at 50/60 Hz and supports 600 V delta systems, making it compatible with most 4W+G configurations and switchgear with remote display. When installing, verify physical clearances and ensure proper wiring to achieve the specified MCOV and transient ratings.
Key specs include 80 kA per phase surge current, 200 kAIC short-circuit rating, 20 kA nominal discharge current, 840 L-G and 840 L-L MCOV, and 600 delta (4W+G) voltage rating. It supports 50/60 Hz operation and is UL 1449 Listed, ensuring reliable protection for critical loads and compliant operation in typical industrial environments.
Yes. SPD080600D2B provides EMI/RFI filtering with up to 50 dB attenuation from 10 kHz to 100 MHz. This helps reduce noise coupling into sensitive control circuits and measurement devices, improving signal integrity, protecting sensors, and enhancing overall system stability in environments with significant electrical noise.
The device is UL 1449 Listed, indicating compliance with established surge protection safety standards. It also meets or exceeds building and safety considerations such as IBC 2006, CBC 2007, and UBC Zone 4 requirements, supporting safe integration into commercial and industrial installations.
SPD080600D2B offers a 15-year warranty, reducing maintenance risk and replacement costs. By preventing transient damage to switchgear and protected loads, it lowers downtime, extends asset life, and reduces unplanned repair expenses. The inclusion of a remote-display compatible design helps facilities monitor protection status with minimal ongoing effort.