Eaton SPD080600Y3J Surge Protection Device - UL Listed
Part Number: SPD080600Y3J
Quick Summary
The Eaton SPD080600Y3J surge protection device protects motor control centers from damaging transients. Designed for panel builders and maintenance teams, it reduces downtime by delivering real-time surge monitoring via an integrated surge counter and silent alarm. UL 1449 Listed and alignment with IBC 2006, CBC 2007, and UBC Zone 4 support code-compliant installations in demanding electrical environments. With 50/60 Hz compatibility, EMI/RFI filtering delivering up to 50 dB attenuation and a compact internal mounting design, it streamlines installation in existing MCCs. The standard feature package plus durable construction translates to lower lifecycle costs and predictable protection for critical drive systems.
Product Information
Extended Description
SPD080600Y3J Eaton: Eaton Surge Protection Device, SPD Series, 80 kA per phase, 600Y/347V (4W+G) rating, 420 L-N, 420 L-G, 420 N-G, 840 L-L MCOV, Internal integrated, Standard feature package and surge counter, used with Motor control centers
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD080600Y3J
UPC
786685324418
Product Length/Depth
9.5 in
Product Height
3.45 in
Product Width
5.4 in
Product Weight
3.5 lb
Warranty
15 year
Certifications
UL 1449 UL Listed
Type
SPD
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package and surge counter
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
420 L-N, 420 L-G, 420 N-G, 840 L-L
Used with
Motor control centers
Voltage rating
347/600 wye (4W+G)
Surge current
80 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
Feature: 80 kA per phase surge rating and 347/600 V (4W+G) performance. Business Impact: Provides robust motor drive protection against high-energy transients, reducing equipment failures and unplanned downtime. Application: Motor control centers in industrial plants where large surges from switching or utility events are common. Feature: Internal integrated mounting and Form C relay contact. Business Impact: Simplifies retrofit and new MCC installations with minimal panel modifications and easy remote signaling for PLCs or BMS. Application: Compact MCC installations in space-constrained switchgear rooms. Feature: Audible alarm with silence button and surge counter. Business Impact: Proactive maintenance planning and quick fault identification, lowering diagnostic time. Application: Facilities requiring traceable surge history for preventive maintenance. Feature: EMI/RFI filtering up to 50 dB between 10 kHz and 100 MHz. Business Impact: Improves control signal integrity and drive performance in crowded electrical environments. Application: Drives and PLCs in high-noise facilities. Feature: 420 L-N, 420 L-G, 420 N-G, 840 L-L operating voltages and 50/60 Hz operation. Business Impact: Broad compatibility with standard MCC feeders and dual-frequency operation to match regional utilities. Application: Global manufacturing lines with mixed voltage profiles. Feature: 15-year warranty and UL 1449 Listed certification. Business Impact: Long-term reliability and regulatory alignment, reducing lifecycle risk and warranty costs. Application: Critical process lines where uptime and compliance are paramount.
Get a Quick Quote for a Eaton SPD080600Y3J
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton SPD080600Y3J?
Enquire Now
FAQs
Installation is streamlined by the SPD080600Y3J's internal integrated mounting and standard feature package. It fits standard MCC spaces, requires minimal panel modification, and uses a Form C relay contact for signaling. Pair it with the built-in surge counter and audible alarm to simplify commissioning and ongoing maintenance without disruptive rewiring.
Key specs include an 80 kA per phase surge rating, 347/600 V (4W+G) and operating voltages of 420 L-N, 420 L-G, 420 N-G, 840 L-L. It supports 50/60 Hz, has a short-circuit rating of 200 kA, and a nominal discharge current of 20 kA. These figures illustrate robust protection for motor drives and MCC feeders.
Yes. The SPD080600Y3J is designed for 50/60 Hz operation and uses an internal integrated mounting method, simplifying installation within motor control centers. The device’s compact footprint, combined with EMI/RFI filtering, enables straightforward retrofits and new installations without extensive panel redesigns.
The SPD080600Y3J is UL 1449 Listed, indicating compliance with established surge protection safety standards. It is also specified to meet or exceed relevant building and electrical codes such as IBC 2006, CBC 2007, and UBC Zone 4 to support code-compliant MCC installations in demanding environments.
ROI derives from reduced downtime, proactive maintenance with the integrated surge counter, and better protection of motor drives from transient events. The 15-year warranty and durable construction further lower lifecycle costs, while EMI/RFI filtering improves drive efficiency and reduces nuisance faults in noisy electrical environments.