Eaton SPD100208Y2F Surge Protection Device - UL Listed

Part Number: SPD100208Y2F
Manufacturer
Eaton
Part number
SPD100208Y2F

Quick Summary

The Eaton SPD100208Y2F surge protection device protects 120/208V panelboards from transient overvoltages in industrial and commercial power systems. Engineers often struggle with nuisance surges that shorten equipment life and trigger costly outages. With certifications UL 1449, UL 1283, and UL Listed, it meets stringent safety and EMI/RFI standards for regulated facilities. The device's internal integration, top-terminal wiring, and compatibility with 4W+G panel configurations streamline installation, reduce wiring errors, and support quick maintenance. By combining robust surge capability with clear status indicators and reliable protection on both L-N and L-L connections, it delivers measurable business value through improved uptime and power quality.

Product Information

Extended Description

SPD100208Y2F Eaton: Eaton SPD, STD PKG, TOP TERMINALS (TT), 100 kA per phase, 208Y/120V (4W+G) rating, 150 L-N, 150 L-G, 150 N-G, 300 L-L MCOV, Internal integrated, Standard feature package, Top Terminal warranty replacement
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD100208Y2F
UPC
786679199862
Product Length/Depth
12 in
Product Height
6 in
Product Width
12 in
Product Weight
6.8 lb
Certifications
UL 1449 UL 1283 UL Listed
Type
Surge protection device
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
150 L-N, 150 L-G, 150 N-G, 300 L-L
Used with
panelboards (PRL-C)
Voltage rating
120/208 wye (4W+G)
Surge current
100 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
Feature: 100 kA per phase interrupt rating and 200 kAIC short-circuit rating. Business Impact: protects critical loads from severe transient events, reducing unplanned downtime and equipment wear. Application: suited for 120/208V panelboards in PRL-C configurations. Long-tail keywords addressed include surge protection device for 120/208V systems and panelboard surge protector. Paragraph continues: Feature: 20 kA nominal discharge current with operating voltages of 150 L-N, 150 L-G, 150 N-G, and 300 L-L. Business Impact: limits energy passed to sensitive electronics, extending device life and lowering maintenance costs. Application: 4W+G panel environments requiring robust transient mitigation. Feature: EMI/RFI filtering up to 50 dB and audible alarm with silence button, plus Form C relay and surge counter with rest button. Business Impact: enhances power quality diagnostics and enables proactive maintenance programs. Application: facilities needing audible alerts and integration into control/monitoring systems. Feature: Internal integrated mounting and top-terminal (TT) design simplifies wiring and improves reliability. Business Impact: reduces installation time and wiring errors, enabling quicker commissioning and safer service. Application: panelboard retrofits and new installs in 120/208V systems. Feature: Meets IBC 2006, CBC2007, and UBC Zone 4 standards with standardized accessories. Business Impact: supports regulatory compliance and reduces risk during audits. Application: construction and industrial environments with strict code requirements.

Get a Quick Quote for a Eaton SPD100208Y2F

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton SPD100208Y2F? Enquire Now

FAQs

Installers should plan wiring to the top terminals (TT) with internal integrated mounting, connect L-N, L-G, and N-G per the 120/208V/Wye configuration, and verify compatibility with four-wire + ground (4W+G) panelboards such as PRL-C. Ensure the device is secured and wired to prevent loose connections, then test the audible alarm and surge counter function during commissioning.
Key specs include 100 kA per phase interrupt rating, 200 kAIC short-circuit rating, 20 kA nominal discharge current, operating at 50/60 Hz, with 150 L-N, 150 L-G, 150 N-G, and 300 L-L MCOV. Voltage rating is 120/208 V (4W+G), and it is designed for use with panelboards in PRL-C configurations.
Yes. SPD100208Y2F is specified for use with panelboards (PRL-C) and is designed for 120/208V four-wire plus ground installations. Its internal mounting and top-terminal wiring simplify integration into PRL-C systems, reducing installation time and wiring errors.
The device carries UL 1449, UL 1283, and UL Listed certifications, aligning with essential safety and EMI/RFI standards. These endorsements support regulatory compliance, reduce risk during inspections, and provide assurance for critical infrastructure installations in regulated environments.
By mitigating transient events, the SPD reduces equipment downtime and wear, lowering maintenance costs and extending service life. Features like audible alarm, surge counter with rest, and Form C relay contact enable proactive monitoring and faster fault diagnosis, delivering measurable uptime improvements and improved power quality across protected loads.