Eaton SPD100208Y3J-ND Surge Protection Device - UL Listed
Part Number: SPD100208Y3J-ND
Quick Summary
The Eaton SPD100208Y3J-ND surge protection device protects motor control centers from transient voltage events, helping prevent motor stalls and control-circuit damage. OEMs and maintenance teams face unpredictable surges that trigger nuisance trips and costly downtime; this device mitigates those risks with documented performance. UL Listed and NFPA 780 compliant, with additional certification context for robust reliability and industry acceptance, including potential 15-year warranty upon registration. With a 120/208V wye rating and EMI/RFI filtering, the unit delivers protection with minimal signal disturbance. This combination translates to better uptime, easier regulatory compliance, and lower total cost of ownership for industrial facilities.
Product Information
Extended Description
SPD100208Y3J-ND Eaton: Eaton Surge Protection Device, Replacement model, 208Y/120V (4W+G) voltage rating, Standard feature package and surge counter, used with Motor control centers
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD100208Y3J-ND
UPC
786685754529
Product Length/Depth
3.54 in
Product Height
5.4 in
Product Width
9.5 in
Product Weight
3.5 lb
Warranty
10 years (15 years when registered on www.eaton.com/spd)
Compliances
NFPA Standard 780
Certifications
UL 96A UL Listed
Type
Replacement model
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package and surge counter
Display
No Display
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
150 L-N, 150 L-G, 150 N-G, 300 L-L
Used with
Motor control centers
Voltage rating
120/208 wye (4W+G)
Surge current
100 kA per phase
Model
Standard with surge counter
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Replacement model optimized for 120/208V wye systems (4W+G) delivers 200 kA short-circuit rating and 100 kA per phase surge capability, while supporting 50/60 Hz operation. Business impact: higher fault tolerance in motor control centers reduces unscheduled downtime and extends motor life. Application: retrofit and new MCC installations in manufacturing environments. Audible alarm with silence button, Form C relay contact, and EMI/RFI filtering up to 50 dB from 10 kHz to 100 MHz. Business impact: rapid fault indication, cleaner electrical noise profiles, and easier predictive maintenance. Application: critical plant spaces where signal integrity matters. Meets IBC 2006, CBC 2007, UBC Zone 4; NFPA 780 compliance, and UL 96A/UL Listed certifications. Business impact: streamlined regulatory compliance and safer deployments. Application: code-compliant facilities and complex projects. Standard feature package includes a surge counter and no display; installation is straightforward with MCCs, reducing wiring and commissioning time. Business impact: lower install costs and faster asset turnover. Application: both retrofit and new builds. Warranty extends 10 years, with 15-year coverage possible after registration; unit weighs 3.5 lb with dimensions 3.54 in depth, 5.4 in height, and 9.5 in width. Business impact: predictable lifecycle budgeting and easier stocking of spares. Application: asset management for industrial plants.
Get a Quick Quote for a Eaton SPD100208Y3J-ND
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton SPD100208Y3J-ND?
Enquire Now
FAQs
The SPD100208Y3J-ND is designed for 120/208 V wye (4W+G) systems and can be integrated into new or retrofit motor control center panels. Its rugged enclosure and 3.54 in depth, 5.4 in height, and 9.5 in width fit typical MCC footprints, with a weight of 3.5 lb for easy handling during panel assembly.
It offers a 200 kA short-circuit rating, 100 kA per phase surge current, and a nominal discharge current of 20 kA, with a 50/60 Hz frequency rating, delivering robust protection against high-energy transients in demanding industrial settings.
Yes. The unit is UL Listed and UL 96A certified, with NFPA 780 compliance for effective lightning and surge protection in accordance with recognized safety standards; it is also designed to meet IBC, CBC, and UBC Zone 4 requirements where applicable.
Installation benefits include a standard feature package with a surge counter and no display, simplifying wiring in MCCs. Maintenance benefits come from the audible alarm with silence button and surge counter, enabling proactive fault tracking and reduced nuisance events; plan for periodic checks of the counter and alarm function during routine commissioning.
The unit carries a 10-year warranty, with 15 years possible when registered on Eaton’s SPD portal. This, along with reliable surge protection and EMI/RFI filtering, supports lower total cost of ownership, reduced downtime, and easier asset lifecycle planning for industrial facilities.