Eaton SPD100220Y1C Surge Protection Device - UL Listed

Part Number: SPD100220Y1C
Manufacturer
Eaton
Part number
SPD100220Y1C

Quick Summary

Eaton SPD100220Y1C surge protection device protects electrical systems from transient surges in industrial panel installations. Unpredictable voltage events can damage sensitive controllers and trigger costly downtime, so reliable protection is essential. It meets or exceeds IBC 2006, CBC 2007, and UBC Zone 4 requirements, with UL 1449 certification and UL Listed status to back safety and performance. In addition, the device delivers robust EMI/RFI filtering and a built-in alarm, providing proactive protection for switchboards, busways, and panelboards. This combination supports compliant, reliable panel protection while delivering measurable business value through reduced maintenance costs and improved line reliability.

Product Information

Extended Description

SPD100220Y1C Eaton: Eaton Surge Protection Device, SPD Series, 100 kA per phase, 220Y/127V (4W+G) rating, 150 L-N, 150 L-G, 150 N-G, 300 L-L MCOV, Internal integrated, used with Switchboard, busways, and panel boards (PRL1a, 2a, 3a, 3e, 4)
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD100220Y1C
UPC
786685321738
Product Length/Depth
9.5 in
Product Height
3.45 in
Product Width
5.4 in
Product Weight
3.5 lb
Warranty
15 year
Certifications
UL 1449 UL Listed
Type
SPD
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Basic feature package
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
150 L-N, 150 L-G, 150 N-G, 300 L-L
Used with
Switchboard, busways, and panelboards (PRL1a, 2a, 3a, 3e, 4)
Voltage rating
127/220 Wye (4W+G)
Surge current
100 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
High surge and fault current ratings translate directly to asset protection and reduced downtime in critical power distribution. The 100 kA per phase surge capability and 200 kAIC short-circuit rating ensure robust response to both external transients and internal faults, making it suitable for switchboards, busways, and panelboards (PRL series). This reduces nuisance outages and maintenance costs while improving system reliability across industrial facilities. Broad voltage and frequency compatibility (127/220 V Wye, 50/60 Hz) simplifies installation across multiple sites, enabling faster deployment and lower wiring errors during integration with existing equipment. EMI/RFI filtering provides up to 50 dB of noise attenuation from 10 kHz to 100 MHz, resulting in cleaner signal integrity for PLCs and control circuits, which translates to fewer false trips and improved process stability. The audible alarm with silence button and Form C relay contact offers immediate fault notification and remote monitoring capabilities, improving maintenance planning and asset monitoring. Internal integrated mounting and a compact footprint (9.5 in L, 5.4 in W, 3.45 in H) streamline installation inside panelboards and switchgear, saving panel space and reducing installation time. A 15-year warranty and UL 1449 UL Listed certifications address long-term reliability and compliance concerns, while certification alignment with IBC, CBC, and UBC standards supports code compliance in regulated environments. The surge counter with rest button provides a straightforward maintenance log, helping facilities track performance and justify ROI for surge protection investments.

Get a Quick Quote for a Eaton SPD100220Y1C

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton SPD100220Y1C? Enquire Now

FAQs

The SPD100220Y1C uses internal integrated mounting and is designed for compact installation within switchboards, busways, and panelboards. Its dimensions (9.5 in L x 5.4 in W x 3.45 in H) and mounting approach help optimize panel space while enabling straightforward wiring and integration with PRL series configurations.
Key ratings include 100 kA per phase surge current, 200 kAIC short-circuit rating, nominal discharge current of 20 kA, and operating voltage of 127/220 V (4W+G). It supports 50/60 Hz operation and provides line-to-neutral, line-to-ground, and line-to-line protection, suitable for diverse distribution panels.
Yes. It meets IBC 2006, CBC 2007, and UBC Zone 4 requirements, and carries UL 1449 certification along with UL Listed status, which supports safety and performance compliance in regulated facilities and panel installations.
The device includes an audible alarm with a silence button, a Form C relay contact for remote signaling, and a surge counter with a rest button for monitoring and maintenance logging, helping teams plan interventions and verify protection performance over time.
It is designed for protection of switchboards, busways, and panelboards, including PRL series configurations. Its 127/220 V Wye rating, robust surge protection, EMI/RFI filtering, and integrated monitoring features make it ideal for industrial power distribution in manufacturing, processing, and facilities environments.