Eaton SPD100230L2A Surge Protection Device - UL 1449
Part Number: SPD100230L2A
Quick Summary
An Eaton SPD100230L2A surge protection device safeguards electrical panels in industrial and commercial applications. Engineers face outages and equipment damage from surges; this device offers fast response, clear signaling, and robust protection. UL 1449 Listed and compliance with IBC 2006, CBC2007, and UBC Zone 4 reinforce reliability in demanding environments. The product integrates EMI/RFI filtering, a 15-year warranty, and compatibility with direct bus mounted panelboards to streamline installation and procurement, delivering tangible business value. Designed for Direct bus mounted panels, SPD100230L2A reduces panel space while simplifying wiring and future upgrades. With a tested operating range -40 to 50 °C and 50/60 Hz compatibility, it supports global installations without redesign.
Product Information
Extended Description
SPD100230L2A Eaton: Eaton Surge Protection Device, SPD Series, 100 kA per phase, 200V, 208V, 220V, 230,V 240V, 277V rating, 320 L-N, 640 L-G, 320 N-G MCOV, Internal integrated, , used with Direct bus mounted panel boards (PRL1a, 2a, 3a, 3e)
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD100230L2A
UPC
786685406657
Product Length/Depth
9.5 in
Product Height
3.45 in
Product Width
5.4 in
Product Weight
3.5 lb
Warranty
15 year
Certifications
UL 1449 UL Listed
Type
SPD
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
320 L-N, 640 L-G, 320 N-G
Used with
Direct bus mounted panelboards (PRL1a, 2a, 3a, 3e)
Voltage rating
200 V, 208 V, 220 V, 230, V 240 V, 277 V
Surge current
100 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
Feature → The SPD100230L2A delivers 100 kA per phase surge current with a 200 kAIC short-circuit rating, directly reducing stress on feeders and downstream equipment. Benefit → Fewer unplanned outages and lower repair costs, enabling safer operation of motors, drives, and controls in demanding environments. Application → Industrial facilities with high transient activity or critical-process loads require robust protection with measurable uptime gains. Feature → Broad voltage and frequency support (200 V, 208 V, 220–230 V, 240 V, 277 V; 50/60 Hz). Benefit → Simplifies protection across mixed feeders, reducing part counts and inventory while ensuring consistent performance. Application → Multi-speed drives and mixed-voltage panel networks in manufacturing sites. Feature → Direct bus mounted panelboard compatibility (PRL1a, 2a, 3a, 3e) with internal mounting. Benefit → Compact footprint and easier installation, accelerating commissioning and retrofit projects. Application → New builds and expansions using Eaton Direct bus panels. Feature → Audible alarm with silence button and Form C relay contact. Benefit → Immediate local awareness plus remote monitoring integration, cutting mean time to detect and respond to faults. Application → Systems requiring alarm signaling to BMS/SCADA or maintenance teams. Feature → EMI/RFI filtering to 50 dB from 10 kHz to 100 MHz. Benefit → Cleaner control networks, improved PLC/DCS reliability, and reduced interference with nearby equipment. Application → Sensitive automation and communication interfaces in process industries. Feature → Surge counter with rest button and 15-year warranty. Benefit → Easy maintenance planning, traceability of surge events, and long-term protection with reduced total cost of ownership. Application → Asset-intensive facilities prioritizing lifecycle savings and serviceability.
Get a Quick Quote for a Eaton SPD100230L2A
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton SPD100230L2A?
Enquire Now
FAQs
SPD100230L2A is designed for use with direct bus mounted panelboards PRL1a, 2a, 3a, and 3e and features internal mounting to minimize space. When installing, verify the supply voltage matches the device’s 200–277 V range, ensure proper clearance, and follow Eaton’s wiring diagrams to route cables cleanly and safely for a reliable, code-compliant installation.
Key ratings include a voltage rating of 200 V, 208 V, 220–230 V, 240 V, and 277 V with 50/60 Hz operation. It provides 100 kA per phase surge current and a 200 kAIC short-circuit rating, with a nominal discharge current of 20 kA. Operating temperature range is -40 to 50 °C.
Yes. SPD100230L2A is specified for 200 V, 208 V, 220–230 V, 240 V, and 277 V systems, at 50/60 Hz. This broad voltage range allows protection across diverse panel voltages without needing multiple devices, simplifying procurement and installation for mixed feeders.
SPD100230L2A is UL 1449 Listed, confirming adherence to essential surge protection safety standards. It also supports compliance with building codes by meeting or exceeding relevant IBC 2006, CBC2007, and UBC Zone 4 criteria, providing confidence for installations in regulated environments and helping with inspection requirements.
The device includes a surge counter with a rest button for event tracking, plus an audible alarm with a silence option for local awareness. A Form C relay enables remote signaling to BMS/SCADA, supporting proactive maintenance and quick response to surge events while improving overall reliability.