Eaton SPD100240H1A Surge Protection Device - UL Listed

Part Number: SPD100240H1A
Manufacturer
Eaton
Part number
SPD100240H1A

Quick Summary

The Eaton SPD100240H1A surge protection device safeguards panel boards against transient overvoltages in 240V delta systems. Without robust protection, electrical surges can trigger unplanned downtime, damaged drives, and costly maintenance across manufacturing lines. UL 1449 listing and UL Listed certification, along with code alignment to IBC 2006, CBC 2007, and UBC Zone 4, reinforce compliance. In practice, engineers gain predictable surge ride-through, extended equipment life, and simplified maintenance planning through a compact, internally mounted solution that integrates with direct bus mounted panels PRL1a, 2a, 3a, 3e. This combination delivers reliability, faster installation, and measurable ROI for industrial facilities.

Product Information

Extended Description

SPD100240H1A Eaton: Eaton Surge Protection Device, SPD Series, 100 kA per phase, 150 L-N, 150 L-G, 150 N-G, 300 L-L MCOV, 240V high-leg delta (4W+G) on B phase rating, Internal integrated, used with Direct bus mounted panel boards (PRL1a, 2a, 3a, 3e)
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD100240H1A
UPC
786685317274
Product Length/Depth
9.5 in
Product Height
3.45 in
Product Width
5.4 in
Product Weight
3.5 lb
Warranty
15 year
Certifications
UL 1449 UL Listed
Type
SPD
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Basic feature package
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
150 L-N, 150 L-G, 150 N-G, 300 L-L
Used with
Direct bus mounted panelboards (PRL1a, 2a, 3a, 3e)
Voltage rating
240 delta (4W+G)
Surge current
100 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
High energy absorption and phase-specific protection are engineered to absorb 100 kA per phase surges without compromising downstream equipment, reducing unplanned downtime and warranty costs. The result is improved equipment uptime and longer life for drives, PLCs, motors, and sensors in critical automation lines, especially where 240V delta configurations are prevalent. The internal integrated mounting simplifies installation and minimizes field wiring, enabling faster commissioning on direct bus mounted panel boards PRL1a, PRL2a, PRL3a, and PRL3e. EMI/RFI filtering delivering up to 50 dB of attenuation improves control signal integrity, stabilizing PLCs and HMIs in noisy factory environments. A 200 kA short-circuit rating provides an additional safety margin while maintaining fast response during fault events. The audible alarm with a silence button, Form C relay contact, and a surge counter with a rest button give clear, actionable feedback for maintenance teams and building management systems. With operating range -40 to 50 °C and a 15-year warranty, this SPD is designed for demanding industrial environments, delivering predictable performance and reducing total cost of ownership.

Get a Quick Quote for a Eaton SPD100240H1A

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton SPD100240H1A? Enquire Now

FAQs

The SPD100240H1A is designed for internal mounting within direct bus mounted panelboards (PRL1a, PRL2a, PRL3a, PRL3e). It features an integrated mounting arrangement that minimizes field wiring and simplifies alignment with bus rails, reducing installation time and potential connection errors. Follow Eaton’s datasheet guidance to ensure correct phase connections and verify clearance for heat dissipation in your enclosure.
This device provides 100 kA per phase surge current with a 200 kAIC short-circuit rating and a nominal discharge current of 20 kA. It operates at 50/60 Hz with an operating voltage of 240V delta (4W+G) and 150 L-N, 150 L-G, 150 N-G, 300 L-L MCOV, making it suitable for 240V delta systems and mixed line configurations commonly found in industrial facilities.
Yes, the SPD100240H1A carries UL 1449 listing and UL Listed certification. It also meets or exceeds relevant industry codes such as IBC 2006, CBC 2007, and UBC Zone 4, supporting regulatory compliance for safety and performance in commercial and industrial installations.
Key maintenance features include a built-in surge counter with a rest button for tracking events, an audible alarm with silence capability, and a Form C relay contact for integration with building automation or remote signaling. The 15-year warranty further enhances total cost of ownership by reducing replacement and service costs while ensuring continued protection against surges.
Ideal for industrial facilities using 240V delta power, the SPD100240H1A protects direct bus mounted panelboards in manufacturing lines, data centers, and controls rooms. Its wide operating temperature range (-40 to 50 °C), EMI/RFI filtering, and compact internal mounting make it resilient in harsh environments while maintaining compatibility with 50/60 Hz systems and standard Eaton panel architectures.