Eaton SPD100240H2F Surge Protection Device - UL Listed

Part Number: SPD100240H2F
Manufacturer
Eaton
Part number
SPD100240H2F

Quick Summary

Surge protection device protects electrical panels from transient overvoltages in industrial control systems. It guards critical equipment and minimizes unplanned downtime caused by power disturbances, helping facilities maintain uptime and productivity. With UL 1449, UL 1283, and UL Listed certifications, this device is tested for reliability in demanding environments and compliant with established safety standards. Designed for 240V delta (4W+G) panel setups, it supports 100 kA per phase surge capability and 20 kA nominal discharge current, while integrating EMI/RFI filtering for cleaner power. For procurement teams, the Eaton SPD100240H2F offers a turnkey protection solution that pairs robust protection with easy installation and long-term cost savings.

Product Information

Extended Description

SPD100240H2F Eaton: Eaton SPD, STD PKG., TOP TERMINALS, 100 kA per phase, 240V high-leg delta (4W+G) on B phase rating, 150 L-N, 150 L-G, 150 N-G, 300 L-L MCOV, Internal integrated, Standard feature package, Top Terminal Warranty Replacement
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD100240H2F
UPC
786679201428
Product Length/Depth
12 in
Product Height
6 in
Product Width
12 in
Product Weight
6.8 lb
Certifications
UL 1449 UL 1283 UL Listed
Type
Surge protection device
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Used with
panelboards (PRL-C)
Voltage rating
240 delta (4W+G)
Surge current
100 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
The SPD100240H2F delivers 100 kA per phase surge current and a 200 kAIC short-circuit rating, providing a strong first line of defense for drives, PLCs, relays, and other critical loads. This translates to fewer nuisance trips, reduced thermal stress, and improved equipment life in demanding panelboard environments. EMI/RFI filtering delivers up to 50 dB of noise attenuation from 10 kHz to 100 MHz, helping control systems achieve cleaner signals and more reliable measurements in busy industrial facilities. An audible alarm with a silence button, along with a Form C relay contact and a surge counter, enables proactive maintenance and easy remote monitoring, reducing unplanned downtime and simplifying fault diagnosis. The top terminal mounting and internal integrated design streamline wiring and retrofit projects, speeding installation in existing cabinets. Compliance with IBC 2006, CBC 2007, and UBC Zone 4 makes this SPD suitable for facilities with strict code requirements, while 50/60 Hz operation covers a broad range of commercial and industrial power networks. The 240 V delta configuration supports panelboard protection right at the source, maximizing uptime and protecting downstream equipment from transients.

Get a Quick Quote for a Eaton SPD100240H2F

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton SPD100240H2F? Enquire Now

FAQs

SPD100240H2F is designed for internal integrated mounting with top terminals, simplifying wiring in 240V delta panelboards. It is compatible with panelboards (PRL-C) and can be mounted in new builds or retrofits. Plan for access to the alarm and form C relay, route wiring to the fault monitor, and verify the device remains within specified operating temperatures (-40 to 50 °C).
The device provides 100 kA per phase surge current and a 200 kAIC short-circuit rating, ensuring robust protection for downstream loads such as drives and PLCs. These ratings help minimize thermal stress and component failure during transient events common in industrial environments.
Yes. The SPD includes EMI/RFI filtering that delivers up to 50 dB of attenuation from 10 kHz to 100 MHz, reducing noise coupling into instrumentation and control signals. This improves signal integrity for measurements, sensors, and PLC inputs in electrically noisy facilities.
SPD100240H2F carries UL 1449, UL 1283, and UL Listed certifications, indicating compliance with recognized safety and performance standards for surge protection devices. This helps ensure reliability in harsh environments and supports code acceptance for industrial installations.
The device offers an audible alarm with a silence button and a surge counter, enabling proactive maintenance and easier fault diagnosis. With high surge and short-circuit ratings, you can extend equipment life, reduce downtime, and lower replacement costs, delivering a favorable total cost of ownership over time.