Eaton SPD100240H2H Surge Protection Device - UL Listed

Part Number: SPD100240H2H
Manufacturer
Eaton
Part number
SPD100240H2H

Quick Summary

The Eaton SPD100240H2H surge protection device shields electrical panels from surges in industrial and commercial settings. When protection is inadequate, unexpected outages and equipment damage disrupt production and drive maintenance costs. It carries UL 1449 and UL 1283 certifications and UL Listed status, with additional compliance to IBC 2006, CBC 2007, and UBC Zone 4 requirements for commercial and industrial facilities. For panel protection, compatibility with 50/60 Hz systems, and a left-terminal design that simplifies wiring, this device helps extend asset life while reducing field retrofit time. Engineered for reliability, it integrates into standard protection packages without special mounting hardware, delivering measurable business value.

Product Information

Extended Description

SPD100240H2H Eaton: Eaton SPD, STD PKG., LEFT TERMINALS, 100 kA per phase, 240V high-leg delta (4W+G) on B phase rating, 150 L-N, 150 L-G, 150 N-G, 300 L-L MCOV, Internal integrated, Standard feature package, Left Terminal Warranty Replacement
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD100240H2H
UPC
786679201442
Product Length/Depth
12 in
Product Height
6 in
Product Width
12 in
Product Weight
6.8 lb
Certifications
UL 1449 UL 1283 UL Listed
Type
Surge protection device
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Used with
panelboards (PRL-C)
Voltage rating
240 delta (4W+G)
Surge current
100 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
SPD100240H2H delivers a high surge capability with 100 kA per phase surge current and a 200 kAIC short-circuit rating, providing robust protection for panelboards and critical loads. This translates to fewer transformer and drive faults, reduced unplanned downtime, and lower repair costs during transient events. The unit is designed for 240 V delta (4W+G) operation and supports both 50 and 60 Hz systems, simplifying selection for diverse industrial environments and accelerating installation without custom wiring. EMI/RFI filtering offers up to 50 dB attenuation from 10 kHz to 100 MHz, delivering cleaner control signals for PLCs and drives and improving overall system reliability. An audible alarm with a silence button, plus a Form C relay contact and a surge counter with a rest button, enables quick fault indication and easy integration with building management or maintenance workflows. With internal integrated mounting and left-terminal wiring, installation is faster and wiring errors are minimized. The device meets IBC 2006, CBC 2007, and UBC Zone 4 requirements, supporting code-compliant installations in commercial and industrial facilities and streamlining audits and inspections.

Get a Quick Quote for a Eaton SPD100240H2H

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton SPD100240H2H? Enquire Now

FAQs

SPD100240H2H is designed for use with panelboards, specifically supporting PRL-C configurations, and operates on 240 V delta (4W+G) systems. Its internal integrated mounting plus left-terminal wiring simplifies field wiring, reducing installation time. It is compatible with both 50 Hz and 60 Hz environments common in industrial facilities, enabling straightforward retrofit and scalable protection as panels grow.
The device provides 100 kA per phase surge current and a 200 kAIC short-circuit rating, with a 20 kA nominal discharge current. These ratings translate into robust protection for breakers, drives, motors, and sensitive electronics, helping maintain process continuity during transient events. Its 12 x 12-inch footprint and 6.8 lb weight support easy installation in standard panel enclosures.
Yes. SPD100240H2H supports high-leg delta configurations by rating 240 delta (4W+G) and 50/60 Hz compatibility. This makes it suitable for industrial systems that use a high-leg delta service, protecting phase-to-phase and phase-to-ground paths. It can be integrated into existing protection schemes within panelboards without extensive rewiring.
SPD100240H2H carries UL 1449 and UL 1283 certifications, along with UL Listed status. These certifications validate surge protection performance and EMI/RFI filtering requirements, supporting compliance with building codes and facilitating audits in commercial and industrial installations.
The device includes an audible alarm with a silence button, a Form C relay contact for signaling, and a surge counter with a rest button. These features enable rapid fault detection, facilitate maintenance planning, and provide tangible uptime improvements, delivering clear return-on-investment through reduced unplanned downtime and easier system health monitoring.