Eaton SPD100240H2J Surge Protection Device - UL 1449 Listed
Part Number: SPD100240H2J
Quick Summary
The Eaton SPD100240H2J surge protection device protects motor control centers from damaging surges. This solution addresses nuisance voltage spikes that can cause premature equipment wear and unexpected downtime. It carries UL 1449 Listed certification with additional code-compliance references to IBC 2006, CBC 2007, and UBC Zone 4, reinforcing reliability in harsh environments. Built for MCC applications, it also aligns with EMI/RFI filtering needs and long-term protection strategies, helping facilities reduce maintenance costs while improving uptime. With its integrated features and robust warranty, it adds value across design, installation, and operation phases using common industry standards and practices.
Product Information
Extended Description
SPD100240H2J Eaton: Eaton Surge Protection Device, SPD Series, 100 kA per phase, 240V high-leg delta (4W+G) on B phase rating, 150 L-N, 150 L-G, 150 N-G, 300 L-L MCOV, Internal integrated, Standard feature package, used with Motor control centers
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD100240H2J
UPC
786685324579
Product Length/Depth
9.5 in
Product Height
3.45 in
Product Width
5.4 in
Product Weight
3.5 lb
Warranty
15 year
Certifications
UL 1449 UL Listed
Type
SPD
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
150 L-N, 150 L-G, 150 N-G, 300 L-L
Used with
Motor control centers
Voltage rating
240 delta (4W+G)
Surge current
100 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
Feature → Business Impact → Application: 100 kA per phase surge capability provides strong transient protection, reducing downstream equipment damage and extending motor life during voltage spikes in industrial facilities. Application: Motor control centers and MCCs requiring high-energy protection with reliable performance across 50/60 Hz power systems. Feature → EMI/RFI filtering up to 50 dB from 10 kHz to 100 MHz lowers conducted noise, improving control signal integrity and reducing interference with sensitive drives and PLC inputs. Application: Precision control environments where electrical noise can affect automation accuracy. Feature → Audible alarm with silence button plus Form C relay contact enables immediate fault indication and integration with building management systems. Application: Plant-wide protection schemes with centralized alarms and automated responses. Feature → Internal integrated mounting simplifies installation and reduces cabling, saving time during panel assembly. Application: Retrofit or new MCC installations seeking streamlined deployment. Feature → Surge counter with rest button provides traceable maintenance data to optimize replacement cycles. Application: Compliance auditing and lifecycle cost planning. Feature → 15-year warranty offers long-term protection and predictable budgeting for OEMs and end users. Application: Enterprise-scale deployments aiming for total cost of ownership reduction.
Get a Quick Quote for a Eaton SPD100240H2J
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton SPD100240H2J?
Enquire Now
FAQs
Install the SPD100240H2J with its internal integrated mounting within a compliant MCC enclosure. Ensure a clean connection to the 240V delta supply (4W+G) and verify 50/60 Hz input compatibility. Plan for access to the audible alarm and the Form C relay for remote signaling. Proper clearance around the device aids heat dissipation and serviceability, reducing installation time and future maintenance.
The device provides 100 kA per phase surge capability and a 200 kAIC short-circuit rating, with a nominal discharge current of 20 kA. It operates at 50/60 Hz with an operating voltage of 240V delta (4W+G) and offers MCOV of 300 V-L-L. The rating supports protection for motor control centers and associated drives against transient events.
Yes. The SPD100240H2J is designed for industrial use with an operating temperature range of -40 to 50 °C, enabling reliable protection in challenging facility environments. Its rugged construction and UL 1449 Listed certification provide confidence in performance and safety across typical MCC installations and related equipment.
This surge protection device is UL 1449 Listed, ensuring compliance with recognized electrical safety standards. It also references established building and electrical codes such as IBC 2006, CBC 2007, and UBC Zone 4, supporting code-compliant installation in commercial and industrial facilities alongside MCC protection requirements.
The 15-year warranty reduces long-term ownership risk, while features like EMI/RFI filtering, audible alarms, a surge counter with rest button, and a Form C relay contact enhance visibility and control. These capabilities help minimize downtime, simplify maintenance planning, and lower unexpected repair costs in motor control centers over the product’s life.