Eaton SPD100600D2G Surge Protection Device - UL Listed

Part Number: SPD100600D2G
Manufacturer
Eaton
Part number
SPD100600D2G

Quick Summary

Eaton SPD100600D2G surge protection device protects electrical panels from transient power spikes in commercial and industrial systems. Voltage surges can cause equipment downtime, costly repairs, and data loss, especially in facilities with sensitive electronics and critical processes. The model is certified to UL 1449, UL 1283, and UL Listed, reinforcing reliability in demanding environments and helping meet regulatory expectations. With Right Terminals and an internal integrated design, it offers straightforward installation and dependable panel protection. This SPD combines robust surge handling with EMI/RFI filtering for up to 50 dB attenuation, supporting uptime, compliance, and reduced incident costs across power-intensive applications.

Product Information

Extended Description

SPD100600D2G Eaton: Eaton SPD, RIGHT TERMINALS, STD PKG, 100 kA per phase, 600V delta (4W+G) rating, 840 L-L MCOV, 840 L-G, Internal integrated, Standard feature package, Right Terminals Warranty Replacement
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD100600D2G
UPC
786679197936
Product Length/Depth
12 in
Product Height
6 in
Product Width
12 in
Product Weight
6.8 lb
Certifications
UL 1449 UL 1283 UL Listed
Type
Surge protection device
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
840 L-G, 840 L-L
Used with
panelboards (PRL-C)
Voltage rating
600 delta (4W+G)
Surge current
100 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
Feature: 100 kA per phase surge current rating provides strong protection against large transient events, reducing the risk of insulation damage and downtime. Business Impact: minimizes unplanned outages and extends the life of connected equipment. Application: ideal for 600V delta (4W+G) panel systems in demanding industrial environments. Feature: Internal integrated design with Right Terminals simplifies wiring and reduces installation time, lowering field labor costs. Business Impact: faster commissioning and fewer external components to manage. Application: panelboards and PRL-C compatible installations. Feature: EMI/RFI filtering delivering up to 50 dB attenuation from 10 kHz to 100 MHz improves signal integrity for PLCs and drives. Business Impact: cleaner control signals, fewer nuisance trips, and improved process stability. Application: drives, controllers, and programmable logic networks. Feature: Audible alarm with silence button, Form C relay contact, and surge counter with rest button enable proactive maintenance. Business Impact: enhances fault visibility and compliance reporting without disrupting operations. Application: facility monitoring and control rooms. Feature: Operating temperature range of -40 to 50 °C and robust construction support reliability in harsh environments. Business Impact: uninterrupted protection across temperature swings and industrial duty cycles. Application: outdoor or non-climate-controlled panels if properly installed. This device also supports straightforward warranty replacement and aligns with standard protection schemes for scalable expansion.

Get a Quick Quote for a Eaton SPD100600D2G

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton SPD100600D2G? Enquire Now

FAQs

Installation is straightforward due to the internal integrated design and Right Terminal configuration. The unit is intended for panelboards and can reduce wiring complexity, enabling faster commissioning. Ensure correct phase and ground connections, follow standard safety practices, and verify compatibility with PRL-C panel systems for a clean, reliable protection solution.
Key specs include a 600 V delta rating (4W+G), 100 kA per phase surge current, 20 kA nominal discharge current, 840 V L-G and 840 V L-L MCOV, a 200 kAIC short-circuit rating, and a frequency range of 50/60 Hz. The operating temperature is -40 to 50 °C, with EMI/RFI filtering up to 50 dB, which informs performance and installation planning.
Yes, the SPD100600D2G is designed for use with panelboards, including PRL-C configurations. Its internal integration and right-terminal design streamline mounting and wiring, reducing installation time and ensuring compatibility with common protection schemes found in commercial and light-industrial facilities.
The device carries UL 1449, UL 1283, and UL Listed certifications. These standards verify surge protection performance, electrical safety, and reliability, which helps ensure regulatory compliance, safer operation, and qualification for use in critical electrical systems across industrial environments.
The SPD includes an audible alarm with a silence button and a surge counter with a rest button, enabling proactive monitoring and quick fault identification without downtime. This feature set supports reduced maintenance costs, improved asset protection visibility, and faster incident response, contributing to a favorable total cost of ownership.