Eaton SPD100600Y1J Surge Protection Device - UL 1449
Part Number: SPD100600Y1J
Quick Summary
SPD100600Y1J surge protection device guards electrical systems against transient overvoltages in motor control centers. The primary pain point it addresses is unplanned downtime caused by power surges and equipment wear from switching events. It carries UL 1449 listing, EMI/RFI filtering up to 50 dB, and meets or exceeds IBC 2006, CBC 2007, and UBC Zone 4 requirements, supporting project safety and regulatory alignment. In addition, the internal mounting and basic feature package simplify installation in existing MCCs, while a 15-year warranty delivers long-term value and predictable maintenance costs. This combination—industrial-grade protection and reliable performance—helps engineers maintain uptime and protect critical drives.
Product Information
Extended Description
SPD100600Y1J Eaton: Eaton Surge Protection Device, SPD Series, 100 kA per phase, 600Y/347V (4W+G) rating, 420 L-N, 420 L-G, 420 N-G, 840 L-L MCOV, Internal integrated, Basic feature package, used with Motor control centers
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD100600Y1J
UPC
786685324517
Product Length/Depth
9.5 in
Product Height
3.45 in
Product Width
5.4 in
Product Weight
3.5 lb
Warranty
15 year
Certifications
UL 1449 UL Listed
Type
SPD
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Basic feature package
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
420 L-N, 420 L-G, 420 N-G, 840 L-L
Used with
Motor control centers
Voltage rating
347/600 wye (4W+G)
Surge current
100 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
Feature: High surge and interrupt ratings provide robust protection against extreme fault events. Business impact: reduces unplanned downtime, minimizes equipment damage, and extends motor drive life. Application: ideal for motor control centers in manufacturing and process industries where peak fault currents can be unpredictable. Long-tail keywords addressed: surge protection for motor control centers, 100 kA per phase protection, 200 kAIC interrupt rating. Feature: 347/600 V wye (4W+G) voltage rating ensures compatible wiring schemes. Business impact: simplifies integration with existing 3-phase infrastructure and motor feeders, reducing wiring complexity and panel space. Application: retrofit projects and new MCC installations in industrial facilities requiring high-voltage protection. Feature: EMI/RFI filtering up to 50 dB minimizes electrical noise that can affect drives and PLCs. Business impact: improves control precision, reduces nuisance trips, and contributes to compliant noise levels in regulated environments. Application: automation and drive systems where sensor accuracy and data integrity matter. Feature: Audible alarm with silence button, Form C relay contact, and surge counter with rest button enable quick diagnostics and remote annunciation. Business impact: accelerates fault diagnosis, improves maintenance planning, and supports plant-wide safety protocols. Application: panel-mounted protection in critical process lines with traceable event records. Feature: Internal integrated mounting with compact dimensions and modest weight simplifies installation inside MCCs. Business impact: reduces installation time, lowers labor costs, and enables easy retrofits into crowded panels. Application: retrofit and new builds where space is at a premium. Feature: 15-year warranty and basic feature package provide predictable total cost of ownership. Business impact: lowers lifecycle risk and supports asset management programs. Application: procurement and maintenance planning for long-term protection of electric drives and automation assets.
Get a Quick Quote for a Eaton SPD100600Y1J
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton SPD100600Y1J?
Enquire Now
FAQs
The SPD100600Y1J is designed for internal integrated mounting within motor control centers. To install, verify the panel provides 347/600 V three-phase supply, then mount the unit in a suitable enclosure space, connect conductors per MCC wiring practices, and configure the Form C relay and audible alarm as needed. The internal mounting simplifies retrofits and minimizes additional hardware requirements, helping shorten commissioning time.
SPD100600Y1J features 100 kA per phase surge current capability, a 200 kAIC interrupt rating, and 20 kA nominal discharge current. It operates at 50/60 Hz with a 347/600 V wye rating, supporting 4W+G configurations. These specs ensure robust protection for MCCs and heavy automation loads against transient events while remaining compatible with common industrial power distribution schemes.
Yes. The SPD100600Y1J is UL 1449 listed and meets performance expectations aligned with IBC 2006, CBC 2007, and UBC Zone 4. This combination supports code-compliant installation in commercial and industrial facilities, reducing project risk while providing proven protection for critical motor control equipment.
SPD100600Y1J includes a surge counter with a rest button and an audible alarm for rapid status checks. It carries a 15-year warranty, which provides long-term protection against device degradation and reduces lifecycle replacement costs. Routine checks focus on confirming alarm status and counter readings during periodic maintenance, with no routine field calibration required.
UL 1449 listing verifies that the SPD meets recognized safety and performance standards, ensuring reliable surge protection for critical equipment. For industrial applications, this reduces risk of panel faults and downtime, simplifies procurement with a trusted certification, and supports compliance with broader electrical protection requirements in motor control centers.