Eaton SPD100600Y2J Surge Protection Device - UL Listed
Part Number: SPD100600Y2J
Quick Summary
SPD100600Y2J is a surge protection device that safeguards motor control centers from transient power disturbances. Unprotected MCCs can suffer unexpected downtime, equipment damage, and increased maintenance costs from lightning and switching surges. UL 1449 certification and UL Listed status, plus performance standards like IBC 2006, CBC 2007, and UBC Zone 4, underline reliability. With EMI/RFI filtering up to 50 dB and an internal mounting design, installation is straightforward and footprint-friendly. Engineers gain long-term protection, reduced downtime, and a clear maintenance path for motor control centers and distributed drives.
Product Information
Extended Description
SPD100600Y2J Eaton: Eaton Surge Protection Device, SPD Series, 100 kA per phase, 600Y/347V (4W+G) rating, 420 L-N, 420 L-G, 420 N-G, 840 L-L MCOV, Internal integrated, Standard feature package, used with Motor control centers
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD100600Y2J
UPC
786685324616
Product Length/Depth
9.5 in
Product Height
3.45 in
Product Width
5.4 in
Product Weight
3.5 lb
Warranty
15 year
Certifications
UL 1449 UL Listed
Type
SPD
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
420 L-N, 420 L-G, 420 N-G, 840 L-L
Used with
Motor control centers
Voltage rating
347/600 wye (4W+G)
Surge current
100 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
High current surge protection provides a 100 kA per phase rating and a 200 kAIC short-circuit capability, guarding MCCs against lightning and switching transients. This translates to fewer nuisance trips, reduced component wear, and improved drive reliability in demanding industrial environments. Application: Motor control centers, distribution panels, and machinery drives that require robust phase-to-phase protection. EMI/RFI filtering delivers up to 50 dB attenuation from 10 kHz to 100 MHz, reducing conducted noise that can affect controllers and sensors. This improves control loop stability, minimizes electromagnetic interference with nearby equipment, and supports compliance with EMI performance standards in industrial settings. Audible alarm with silence button and a Form C relay contact enable quick fault notification and seamless control-system integration. Internal integrated mounting and a compact footprint (9.5 in L x 5.4 in W x 3.45 in H) simplify installation inside standard MCC cabinets and reduce panel depth. With a 347/600 V wye rating and 50/60 Hz compatibility, this device aligns with common plant electrical architectures while providing a 15-year warranty and UL 1449 listing for lifecycle reliability. Standard feature packaging reduces procurement complexity by including essential accessories.
Get a Quick Quote for a Eaton SPD100600Y2J
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton SPD100600Y2J?
Enquire Now
FAQs
Yes. SPD100600Y2J is designed for MCC protection with internal integrated mounting that fits within typical MCC cabinets. It supports 347/600 VAC, 50/60 Hz operation, and the 9.5 inch length, 5.4 inch width, and 3.45 inch height dimensions help minimize panel depth while delivering robust surge protection for drives and feeders.
Key specs include 100 kA per phase surge current with a 200 kAIC short-circuit rating, nominal discharge current of 20 kA, operating voltage 347/600 VAC, 50/60 Hz compatibility, EMI/RFI filtering up to 50 dB, and protection for L-N, L-G, N-G, and L-L connections. It is rated for -40 to 50 °C and includes a Form C relay and audible alarm.
SPD100600Y2J is well-suited for motor control centers, electrical panels, and industrial drives where transients from lightning or switching events can cause equipment damage. Its internal mounting and standard feature package simplify installation in MCCs, while the 347/600 VAC rating aligns with common industrial power systems.
SPD100600Y2J carries UL 1449 certification and UL Listed status, providing recognized protection against transients. It also aligns with performance standards referenced in IBC 2006, CBC 2007, and UBC Zone 4, ensuring compliance with typical building and electrical code requirements in industrial environments.
The unit provides a 15-year warranty, reducing long-term lifecycle costs. Features such as an audible alarm, silence button, and a Form C relay contact enable proactive fault detection and easier integration with control systems. EMI/RFI suppression and robust surge protection translate to lower downtime and extended equipment life, improving overall return on investment.