Eaton SPD100600Y3A Surge Protection Device - UL Listed

Part Number: SPD100600Y3A
Manufacturer
Eaton
Part number
SPD100600Y3A

Quick Summary

Eaton SPD100600Y3A surge protection device delivers reliable transient protection for direct bus mounted panelboards. Industrial power systems face nuisance surges that cause downtime and equipment damage; this unit mitigates that risk. It is UL 1449 Listed and designed to meet industry standards such as IBC 2006, CBC 2007, and UBC Zone 4, providing robust protection in demanding environments. The 347/600 V rating (4W+G) and EMI/RFI filtering deliver improved power quality for critical drives, PLCs, and controllers, while the internal integration simplifies installation and ongoing protection. For engineering teams, this translates to longer equipment life and lower total cost of ownership, supported by reliable protection and straightforward maintenance.

Product Information

Extended Description

SPD100600Y3A Eaton: Eaton Surge Protection Device, SPD Series, 100 kA per phase, 600Y/347V (4W+G) rating, 420 L-N, 420 L-G, 420 N-G, 840 L-L MCOV, Internal integrated, and surge counter, used with Direct bus mounted panel boards (PRL1a, 2a, 3a, 3e)
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD100600Y3A
UPC
786685317519
Product Length/Depth
9.5 in
Product Height
3.45 in
Product Width
5.4 in
Product Weight
3.5 lb
Warranty
15 year
Certifications
UL 1449 UL Listed
Type
SPD
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package and surge counter
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
420 L-N, 420 L-G, 420 N-G, 840 L-L
Used with
Direct bus mounted panelboards (PRL1a, 2a, 3a, 3e)
Voltage rating
347/600 wye (4W+G)
Surge current
100 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
The SPD100600Y3A delivers a 100 kA per phase surge rating and a 200 kAIC short‑circuit rating, providing robust defense for feeders, drives, and sensitive digital loads. This protection minimizes nuisance outages, data loss, and equipment damage in industrial control panels and switchgear assemblies. The device is rated for 347/600 V (4W+G) with a 50/60 Hz frequency, enabling broad compatibility in mixed‑voltage facilities and motor starter circuits. EMI/RFI filtering provides up to 50 dB of attenuation from 10 kHz to 100 MHz, improving power quality for PLCs and HMIs. It also supports Direct bus mounted panelboards per PRL1a, 2a, 3a, and 3e, simplifying integration into existing architectures. The internal mounting reduces enclosure space and eliminates external hardware, accelerating protection deployment in retrofit projects. The footprint is 9.5 in L × 5.4 in W × 3.45 in H with a 3.5 lb weight, easing handling during installation. A surge counter with a rest button and an audible alarm (with silence option) provide immediate visibility and easy maintenance planning during routine checks. Form C relay contacts enable remote signaling to plant controllers or building management systems, supporting automated responses such as safe shutdowns or alert notifications when surges occur. With a wide operating temperature range of -40 to 50 °C, this SPD maintains performance in harsh factory environments, including areas with temperature extremes. The unit’s 15‑year warranty and UL 1449 listing reinforce long‑term reliability for critical electrical protection programs, while its compact, integrated design reduces total installed cost and simplifies code‑compliant installations. In practice, this translates to improved uptime, reduced spare‑parts inventory, and a clearer path to regulatory compliance for industrial facilities.

Get a Quick Quote for a Eaton SPD100600Y3A

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton SPD100600Y3A? Enquire Now

FAQs

The SPD100600Y3A uses an internal mounting method designed for direct bus mounted panelboards (PRL1a, 2a, 3a, 3e). Its compact 9.5 in L Ă— 5.4 in W Ă— 3.45 in H footprint and 3.5 lb weight simplify retrofit and new installations, reducing cabinet space and eliminating the need for external surge cabinets. Follow the included specification sheet for wiring diagrams and sequence of commissioning, and verify 50/60 Hz input compatibility and the 347/600 V rating to ensure proper coordination with downstream electrical equipment.
SPD100600Y3A provides a 100 kA per phase surge rating and a 200 kAIC short‑circuit rating, with a nominal discharge current of 20 kA. It operates at 50/60 Hz and is rated for 347/600 V (4W+G). The device also offers EMI/RFI filtering up to 50 dB from 10 kHz to 100 MHz, enhancing power quality for sensitive devices like PLCs and drives. It supports -40 to 50 °C ambient operation to handle harsh environments.
Yes. The SPD100600Y3A is designed for industrial control panels with an operating temperature range of -40 to 50 °C, ensuring reliability in temperature‑extreme facilities. Its internal integration and direct bus mounting reduce exposure to external moisture and dust, while EMI/RFI filtering and a robust surge capability protect critical loads from transient events that commonly occur on factory floors and in motor drive systems.
SPD100600Y3A carries UL 1449 listing, indicating compliance with recognized safety standards for surge protection devices. Eaton backs the unit with a 15‑year warranty, offering long‑term protection for mission‑critical applications and helping justify maintenance budgets and regulatory compliance across industrial facilities.
By protecting critical drives, controllers, and sensors from transient overvoltages, the SPD100600Y3A reduces unplanned downtime and spare‑parts consumption. Features such as an audible alarm, surge counter with rest button, and Form C relay contacts enable proactive maintenance and faster fault attribution, resulting in lower maintenance labor and improved asset longevity in a wide range of manufacturing and processing environments.