Eaton SPD100600Y3G Surge Protection Device - UL 1449 Listed
Part Number: SPD100600Y3G
Quick Summary
The SPD100600Y3G surge protection device from Eaton guards critical electrical panels against transient events in commercial and industrial facilities. Unreliable protection can cause costly outages and equipment damage, especially in sensitive control circuits and panelboards. It carries UL 1449, UL 1283 and UL Listed certifications, with compliance cues such as IBC/CBC/UBC expectations to support safety and reliability. This solution integrates with Eaton’s protection ecosystem to simplify procurement, serviceability, and ongoing compliance while delivering robust surge mitigation and monitoring capabilities for mission-critical operations.
Product Information
Extended Description
SPD100600Y3G Eaton: Eaton SPD, STD W/COUNTER PKG., RIGHT TERMINALS , 100 kA per phase, 600Y/347V (4W+G) rating, 420 L-N, 420 L-G, 420 N-G, 840 L-L MCOV, Internal integrated, Standard feature package and surge counter, Right Terminals Warranty Replacement
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD100600Y3G
UPC
786679198940
Product Length/Depth
12 in
Product Height
6 in
Product Width
12 in
Product Weight
6.8 lb
Certifications
UL 1449 UL 1283 UL Listed
Type
Surge protection device
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package and surge counter
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
420 L-N, 420 L-G, 420 N-G, 840 L-L
Used with
panelboards (PRL-C)
Voltage rating
347/600 wye (4W+G)
Surge current
100 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
Feature: 100 kA per phase surge current with 420 L-N, 420 L-G, 420 N-G operating voltages and 840 L-L MCOV. Business Impact: High-energy transients are rapidly clamped, reducing insulation stress and extending component life in motor drives, PLCs, and control panels. Application: Suitable for 347/600 V wye panelboards (4W+G) in industrial facilities and data centers. Feature: Internal integrated architecture with right-terminal configuration. Business Impact: Simplifies installation and reduces field wiring errors, cutting commissioning time and labor costs. Application: Ideal for panelboard retrofits and new builds where space and wiring access are constrained. Feature: Audible alarm with silence button, Form C relay contact and EMI/RFI filtering up to 50 dB from 10 kHz to 100 MHz. Business Impact: Immediate fault notification plus noise reduction improves equipment reliability and reduces nuisance shutdowns. Application: Critical for sensitive automation lines and EMI-sensitive instrumentation.Feature: Surge counter with rest button and standard feature package. Business Impact: Enables proactive maintenance scheduling and traceable protection history for compliance reporting. Application: Useful for asset management programs and warranty considerations across multiple devices.Feature: Compatibility with panelboards and PRL-C configurations, 50/60 Hz operation, and a -40 to 50 °C operating range. Business Impact: Broad installation flexibility supports global facilities and diverse electrical diagrams. Application: Retrofit projects and new installations in manufacturing, water treatment, and process industries.Feature: Certifications and compliance (UL 1449, UL 1283, UL Listed) with IBC/CBC/UBC alignment. Business Impact: Enhances regulatory acceptance, reduces risk during audits, and supports safety programs. Application: Essential for facilities subject to strict electrical protection standards and corporate risk controls.
Get a Quick Quote for a Eaton SPD100600Y3G
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton SPD100600Y3G?
Enquire Now
FAQs
What mounting and wiring choices are recommended for the SPD100600Y3G in PRL-C panelboards? The unit features right terminals and an internally integrated mounting approach, which simplifies field wiring, reduces misconnections, and speeds commissioning. Ensure adequate space for heat dissipation, follow the 50/60 Hz wiring diagram, and verify compatible outage coordination with the main protection scheme.
The device provides 100 kA per phase surge current with a 200 kA short-circuit rating and a 20 kA nominal discharge current. These specs translate to rapid clamping of high-energy transients, protecting PLCs, motor drives, and control panels from voltage spikes that can degrade insulation and trigger outages.
Yes. The SPD100600Y3G carries UL 1449, UL 1283 certifications and UL Listed status, ensuring compliance with established electrical protection standards. This helps support regulatory audits and safety programs across industrial facilities and reduces risk in mission-critical environments.
The device operates at 50/60 Hz and supports an operating temperature range from -40 to 50 °C. This makes it suitable for a wide range of industrial locations, including outdoor installations with appropriate enclosure protection, and ensures stable protection across different commissioning scenarios.
The surge counter with a rest button provides traceable protection history, facilitating uptime reporting and proactive maintenance. An audible alarm and silence option help operators respond quickly to events, while EMI/RFI filtering reduces signal noise. Together with long-term warranty support, these features contribute to a lower total cost of ownership for critical automation assets.