Eaton SPD120208Y2F Surge Protection Device - UL Listed

Part Number: SPD120208Y2F
Manufacturer
Eaton
Part number
SPD120208Y2F

Quick Summary

The Eaton SPD120208Y2F surge protection device guards 120/208V panelboards against damaging transients, helping keep critical equipment online in data centers, manufacturing lines, and distribution facilities. When surges spike, downtime, equipment damage, and warranty costs can escalate quickly; this device clamps fast rising voltages and signals faults before they propagate. UL 1449, UL 1283, and UL Listed status underscore its safety and reliability, while the integrated EMI/RFI filtering and audible alarm address both compliance and operator awareness. By combining top-terminal connection with a compact form factor, it streamlines installation on existing panelboards and supports reliable protective coverage for critical loads, offering a tangible business value in reliability, safety, and total cost of ownership.

Product Information

Extended Description

SPD120208Y2F Eaton: Eaton SPD, TOP TERMINALS , STD PKG., 120 kA per phase, 208Y/120V (4W+G) rating, 150 L-N, 150 L-G, 150 N-G, 300 L-L MCOV, Internal integrated, Standard feature package, Top Terminals Warranty Replacement
Product Name
Eaton SPD series surge protection device
Catalog Number
SPD120208Y2F
UPC
786679199947
Product Length/Depth
12 in
Product Height
6 in
Product Width
12 in
Product Weight
6.8 lb
Certifications
UL 1449 UL 1283 UL Listed
Type
Surge protection device
Special features
Meets or exceeds the requirements specified in IBC ®2006, CBC2007, and UBC®Zone 4. Audible alarm with silence button. Form C relay contact. EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz. Surge counter with rest button
Accessories
Standard feature package
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC
Nominal Discharge Current
20 kA
Operating voltage
150 L-N, 150 L-G, 150 N-G, 300 L-L
Used with
panelboards (PRL-C)
Voltage rating
120/208 wye (4W+G)
Surge current
120 kA per phase
Short-circuit rating
200 kA
Operating temperature
-40 to 50 °C
Mounting Method
Internal integrated
Feature: High surge capability up to 120 kA per phase. Business Impact: Provides robust protection for critical loads against high-energy transients, reducing the risk of equipment damage and unplanned downtime. Application: Suitable for panelboards in manufacturing lines and data centers utilizing 120/208V systems. Long-tail keywords: 120 kA per phase surge protection, panelboard surge protection, durable transient suppression. Feature → Business Impact → Application. Feature: 208Y/120V (4W+G) rating with L-N, L-G, N-G thresholds and 150 L-N/L-G/N-G operating voltages. Business Impact: Ensures compatibility with multi-wire 4W+G systems, enabling safer distribution and easier wiring. Application: Commercial and light industrial panel installations. Long-tail keywords: 208Y/120V protection, L-N L-G N-G ratings, 150 V operating voltage. Feature: Form C relay contact and audible alarm with silence button. Business Impact: Enables remote signaling for maintenance and reduces nuisance alarms, improving uptime planning. Application: Facility monitoring and control schemes. Long-tail keywords: Form C relay, audible alarm, silence button. Feature: EMI/RFI filtering providing up to 50 dB attenuation from 10 kHz to 100 MHz. Business Impact: Improves drive and control system performance by reducing noise and EMI-related faults. Application: PLC, VFD, and instrumentation protection. Long-tail keywords: EMI/RFI filtering 50 dB, noise attenuation, control system protection. Feature: Internal integrated mounting with top terminals. Business Impact: Simplifies installation, reduces wiring complexity, and supports faster retrofits on existing panelboards. Application: Retrofit projects and new builds with space constraints. Long-tail keywords: top terminals, internal integrated mounting, quick wiring. Feature: Meets IBC 2006, CBC 2007, UBC Zone 4 as noted in features. Business Impact: Supports code-compliant protection for large facilities and critical environments. Application: Industrial, commercial, and healthcare facilities. Long-tail keywords: IBC CBC UBC Zone 4 compliance, building code protection. Feature: Compatibility with PRL-C panelboards and standard feature package. Business Impact: Streamlines procurement and reduces integration risk for common Eaton protection schemes. Application: Panelboard protection and OEM compatibility. Long-tail keywords: PRL-C compatibility, standard feature package, Eaton protection devices.

Get a Quick Quote for a Eaton SPD120208Y2F

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton SPD120208Y2F? Enquire Now

FAQs

SPD120208Y2F features top-terminal mounting and an internal integration design, simplifying wiring on PRL-C panelboards. For best results, mount in a ready-access location, verify clearance for the 12 in x 12 in footprint, and connect L-N, L-G, and N-G per the 120/208V configuration to ensure proper transient suppression and signaling.
Key specs include a 120 kA per phase surge current rating, nominal discharge current of 20 kA, voltage rating of 120/208V (4W+G), operating voltages L-N 150, L-G 150, N-G 150, and L-L 300. It supports 50/60 Hz operation and offers a short-circuit rating of 200 kAIC with an operating temperature range of -40 to 50 °C.
Yes. The device is UL 1449, UL 1283, and UL Listed, meeting stringent safety standards. It also aligns with IBC 2006, CBC 2007, and UBC Zone 4 guidelines, helping facilities comply with high-occupancy and critical-load protection requirements.
It includes EMI/RFI filtering up to 50 dB, significantly reducing electrical noise that can affect drives and controllers. An audible alarm with silence button and a Form C relay contact provide immediate fault signaling and remote integration for maintenance planning.
By preventing transient damage, reducing downtime, and extending panelboard life, this SPD lowers total cost of ownership. The integrated alarm and robust UL listings minimize maintenance complexity and warranty concerns while enabling easier diagnostics and faster repairs.