Quick Summary

Eaton SPECIAL598 molded case circuit breaker protects power distribution and motor control panels with a robust, three-pole design. Engineers often struggle to balance high-current protection with compact enclosure space and fast diagnostics. This unit carries UL Listed certification and supports a 400 A rating at 600 Vac / 250 Vdc with 65 kAIC at 240 Vac and 35 kAIC at 480 Vac, helping meet reliability and safety requirements. Built for compatibility in industrial environments, it pairs with TA350K terminals and KD frame configurations to streamline procurement, install, and maintenance while delivering scalable protection for evolving automation needs.

Product Information

Extended Description

SPECIAL598 Eaton: Eaton Series C complete molded case circuit breaker, K-frame, KD, Electronic LI trip, Three-pole, 400A, 600 Vac, 250 Vdc, 65 kAIC at 240 Vac, 35 kAIC at 480 Vac, Line and load, 1A-1B rear with right pigtail, 110-127 Vac with left pigtail
Product Name
Eaton Series C complete molded case circuit breaker
Catalog Number
SPECIAL598
UPC
786679018101
Product Length/Depth
0.01 in
Product Height
0.01 in
Product Width
0.01 in
Product Weight
0.01 lb
Certifications
UL Listed
Catalog Notes
TA350K terminals
Amperage Rating
400 A
Voltage rating
600 Vac, 250 Vdc
Trip Type
T165
Circuit breaker type
KD
Circuit breaker frame type
Molded case switch
Auxiliary switch
1A-1B rear with right pigtail
Terminals
Line and load
Undervoltage release
110-127 Vac with left pigtail
Frame
K
Interrupt rating
35 kAIC at 480 Vac 65 kAIC at 240 Vac
Number of poles
Three-pole
Feature → Business Impact → Application: 400 A amperage rating enables full-load protection for demanding loads in panel boards and MCCs, reducing nuisance trips and safeguarding equipment. This translates to improved uptime and predictable maintenance costs in manufacturing and process facilities. Application: Use in motor control centers and distribution panels requiring high interrupt capability and reliable protection under mixed AC/DC loads. Feature → Business Impact → Application: 600 Vac / 250 Vdc voltage ratings extend protection across standard industrial power domains, supporting both AC mains and DC control circuits for conveyors, pumps, and drives. Application: Ideal for mixed-voltage environments where a single MCCB addresses both power and control circuits. Feature → Business Impact → Application: KD frame with a three-pole configuration delivers a compact, adaptable form factor that fits standard switchgear footprints, simplifying retrofits and new installations. Application: Suitable for panel retrofit projects and new builds in automation lines. Feature → Business Impact → Application: Trip Type T165 and 65 kAIC at 240 Vac / 35 kAIC at 480 Vac provide precise coordination with upstream protection devices, minimizing arc exposure and improving fault clearance times. Application: Critical for safety-conscious facilities with heavy motor loads. Feature → Business Impact → Application: 110-127 Vac undervoltage release and 1A-1B rear right pigtail/left pigtail terminals enable integrated control circuits and remote signaling, reducing wiring complexity. Application: Useful in safety interlock schemes and automated control panels. Feature → Business Impact → Application: TA350K terminal catalog note ensures compatibility with existing lugs and terminal hardware, accelerating procurement and reducing engineering time. Application: Streamlined sourcing for maintenance teams working across multiple Eaton MCCB platforms.

Get a Quick Quote for a Eaton SPECIAL598

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton SPECIAL598? Enquire Now

FAQs

Install the SPECIAL598 as a three-pole device within a KD frame enclosure, using TA350K-rated terminals. Connect line and load terminals per Eaton MCCB installation guidelines, and utilize the 1A-1B rear right pigtail and 110-127 Vac left pigtail for auxiliary and undervoltage release circuits to simplify wiring and improve reliability.
The SPECIAL598 is rated for 400 A with a voltage range of 600 Vac and 250 Vdc. It provides a 65 kAIC interrupt rating at 240 Vac and 35 kAIC at 480 Vac, with a three-pole KD frame and T165 trip mechanism, suitable for demanding industrial loads.
Yes, the SPECIAL598 is UL Listed. This certification indicates it meets recognized safety standards for electrical protection devices, helping facilities comply with regulatory requirements and reducing risk during audits and inspections.
Best suited for motor control centers and power distribution panels in industrial settings, where high-current protection, reliable short-circuit interruption, and compatibility with standard terminal setups (TA350K) are essential for uptime and safety in conveyors, pumps, and automated lines.
Plan for periodic inspection of the trip mechanism and terminals, verify UL Listed status, and reference the MOEM MCCB product selection guides for compatible accessories. With its robust interrupt ratings and standard form factor, the unit supports straightforward replacement and compatibility within Eaton’s MCCB ecosystem.