Eaton SPS42870XC Linear Fluorescent Fixture - IP66

Part Number: SPS42870XC
Manufacturer
Eaton
Part number
SPS42870XC

Quick Summary

Eaton SPS42870XC is a hazardous-location linear fluorescent fixture used for harsh industrial environments. Engineering teams rely on this design to minimize downtime and ingress exposure while delivering consistent illumination. It carries NEC/CEC compliance with Class I, Division 2, Class II, Division 2, and Class III ratings, plus NEMA 4 and IP66 protection for classified locations. Through-feed wiring, a 4 ft two-lamp configuration, and a 120–277 Vac, 50/60 Hz power range deliver reliable performance across demanding applications. This combination supports maintenance efficiency, longer service life, and easier procurement, making it a practical choice for plants requiring rugged, compliant lighting that reduces total cost of ownership.

Product Information

Extended Description

SPS42870XC Eaton: Eaton Crouse-Hinds series Pauluhn Intrepid SPS linear fluorescent light fixture,3/4" entry (2) hubs,50/60 Hz,4 ft lamp,Fluorescent,Clear polycarbonate lens,T12HO RDC,304 stainless steel,2-lamp,Through feed,120-277 Vac,48W
Product Name
Eaton Crouse-Hinds series Pauluhn Intrepid SPS linear fluorescent light fixture
Catalog Number
SPS42870XC
UPC
662276497726
Product Length/Depth
52.8 in
Product Height
5 in
Product Width
7.63 in
Product Weight
25.1 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class II, Division 2 Class III
NEMA Rating
4
Ingress protection (IP) ratings
IP66
Lamp type
Fluorescent
Material
304 stainless steel
Lamp length
4 ft
Number of lamps
2-lamp
Light type
T12HO RDC
Voltage rating
120-277 Vac
Frequency rating
50/60 Hz
Style
Through feed
Entry size
3/4"
Entry type
(2) hubs
Wattage
48W
Lens material
Clear polycarbonate
Feature → Business Impact → Application: 304 stainless steel housing provides excellent corrosion resistance in wet or chemically aggressive environments, extending fixture life and lowering replacement costs. This is critical in chemical plants, refining facilities, and offshore or wash-down areas where durability directly impacts uptime. Feature → Business Impact → Application: IP66 and NEMA 4 enclosure protection guard against dust, water jets, and washdowns, ensuring consistent performance and regulatory compliance in harsh locations. Ideal for outdoor or wet plant areas and maintenance-intensive facilities needing dependable illumination. Feature → Business Impact → Application: Clear polycarbonate lens combined with a 4 ft, two-lamp T12HO RDC arrangement delivers high light output with strong impact resistance, supporting productive work environments and reducing replacement cycles. Great for process floors, loading docks, and maintenance corridors in hazardous settings. Feature → Business Impact → Application: Through-feed wiring with 3/4" entry and two hubs simplifies installation and future reconfiguration, cutting field labor and splice points while enabling rapid layout changes in expanding plants. Applied to retrofit projects or new builds where space is constrained and reliability matters. Feature → Business Impact → Application: Wide voltage operating range 120–277 Vac at 50/60 Hz improves compatibility with existing power systems, reducing inventory needs and enabling seamless integration in multi-zone facilities, platforms, and warehouses. Feature → Business Impact → Application: 48W wattage provides efficient operation in double-lamp configurations, contributing to lower energy costs over time and aligning with sustainability goals in industrial facilities.

Get a Quick Quote for a Eaton SPS42870XC

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton SPS42870XC? Enquire Now

FAQs

The SPS42870XC carries NEC/CEC compliance with Class I, Division 2, Class II, Division 2, and Class III ratings, plus IP66 ingress protection and NEMA 4 enclosure. These features support safe operation in hazardous and classified locations and meet common industrial regulatory requirements.
Yes. The fixture operates across 120–277 Vac and supports 50/60 Hz, making it compatible with a wide range of industrial power systems and reducing the need for multiple transformers or alternative luminaires.
The 2-lamp, 4 ft configuration provides higher light output per fixture while limiting maintenance cycles. With through-feed wiring and a durable stainless-steel housing, maintenance downtime is reduced, and lamp replacement can be performed efficiently in hazardous environments.
Its 304 stainless steel body, IP66 and NEMA 4 protection, and Class I, Division 2/ II, Division 2/ III ratings make it well-suited for chemical plants, refineries, and other classified sites where ingress protection and corrosion resistance are essential.
Plan for through-feed wiring with 3/4" entry and two hubs, use the 4 ft length to optimize layout, and ensure mounting follows NEC guidelines for hazardous locations. Verify power is within 120–277 Vac and that the environment maintains the IP66 protection requirements for ongoing reliability.