Eaton TP7122 Weatherproof Outlet Box - Two-Gang Die Cast
Part Number: TP7122
Quick Summary
Eaton TP7122 weatherproof outlet box protects two-gang outlets in harsh industrial environments. Many enclosures fail to seal against moisture, leading to corrosion, equipment faults, and costly downtime. This model is NEC/CEC compliant and suitable for ordinary/non-hazardous locations, with clear area classification. The enclosure supports reliable sealing against moisture, reducing maintenance cycles for critical systems. Designed for two-gang configurations, it's well suited for control panels, outdoor drives, and field junctions, delivering consistent performance with NEC/CEC compliance. Its die-cast aluminum construction delivers durability and quicker field installation, while the five 3/4 in knockout holes and 2 in depth support flexible wiring for control panels, outdoor locations, and equipment rooms.
Product Information
Extended Description
TP7122 Eaton: Eaton Crouse-Hinds series weatherproof outlet box, 30.5 cu in, Gray, 2" deep, Die cast aluminum, Two-gang, (5) 3/4" outlet holes, one hole around each of the four sides, one hole on the back
Product Name
Eaton Crouse-Hinds series weatherproof outlet box
Catalog Number
TP7122
UPC
786189071221
Product Length/Depth
4.63 in
Product Height
4.56 in
Product Width
2.06 in
Product Weight
0.83 lb
Area classification
Ordinary/Non-Hazardous Locations
Standards type
NEC/CEC
Number of gangs
Two-gang
Depth
2"
Outlet holes
(5) 3/4 in
Capacity
30.5 cubic in
Color
Gray
Material
Die cast aluminum
Crouse-Hinds series Weatherproof portfolio catalog pages
Weatherproof Outlet Boxes and Covers Canadian certification
Weatherproof Outlet Boxes and Covers Canadian certification
TP7122 SLDDRW drawing
TP7122 SLDDRW drawing
Eaton Specification Sheet - TP7122
Feature: Die-cast aluminum construction provides rugged weatherproofing. Business Impact: Delivers durable protection against impact, moisture, and environmental exposure, reducing replacement costs. Application: Ideal for outdoor enclosures, control panels, and rugged factory spaces. Feature: 30.5 cubic inches of capacity with five 3/4 inch knockout holes. Business Impact: Enables compact yet versatile wiring layouts, supporting multiple devices without overcrowding. Application: Used for two-gang installations requiring flexible wiring options in space-constrained panels. Feature: 2 inch depth and compact exterior dimensions. Business Impact: Facilitates straightforward installation in tight spaces while preserving seal integrity. Application: Perfect for conduit runs and field wiring in equipment rooms and outdoor applications. Feature: NEC/CEC compliance and ordinary/non-hazardous area classification. Business Impact: Ensures code-conforming installations and audit readiness, reducing compliance risk. Application: Suitable for general industrial environments where safety and standards adherence are critical. Feature: Gray die-cast aluminum, weatherproof finish. Business Impact: Combines durability with a maintenance-friendly finish, lowering lifecycle costs. Application: Reliable for harsh environments, outdoor drives, and general protective housings.
Get a Quick Quote for a Eaton TP7122
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton TP7122?
Enquire Now
FAQs
TP7122 is well suited for outdoor and industrial installations that require two-gang outlets in a single weatherproof enclosure. It features a 30.5 cu in capacity, 2 in depth, and five 3/4 inch knockout holes, making it easy to route wires for control panels, drives, or field junctions while protecting against moisture and dust.
Install TP7122 by aligning it for a two-gang footprint, securing the die-cast aluminum body to the mounting location, and connecting conductors through the five 3/4 in knockouts. The box’s 4.63 in length, 4.56 in height, and 2.06 in width support compact wiring inside, while the 2 in depth keeps devices protected inside.
Yes. TP7122 is NEC/CEC compliant and designed for ordinary/non-hazardous locations, backed by NEC/CEC standards and area classification guidance. This ensures compliance during installation in general industrial environments and outdoor settings where moisture exposure is possible, helping you meet code requirements without sacrificing enclosure performance. The area classification designation informs suitable installation zones, while compliance with NEC/CEC standards reduces risk of non-conformance during audits.
Key specs include 30.5 cubic inches of capacity, 4.63 in length, 4.56 in height, 2.06 in width, and a 2 in depth. The gray, die-cast aluminum body provides durability, while five 3/4 in knockout holes offer flexible wiring options. Weight is approximately 0.83 lb, supporting easier handling on site. Designed for simple mounting in two-gang installations with field wiring efficiency.
Maintenance is minimal due to the corrosion-resistant die-cast aluminum and sealed weatherproof design within ordinary locations. Regular inspection of the enclosure and knockouts ensures continued seal integrity, and the durable construction reduces replacement frequency in harsh environments, lowering total cost of ownership while maintaining consistent electrical performance. Using standard mounting patterns and universal wiring practices, TP7122 minimizes field rework and training time for technicians.