Eaton slim GFCI receptacle TRGF15GY-BX-L - cULus Listed

Part Number: TRGF15GY-BX-L
Eaton logo
Manufacturer
Eaton
Part number
TRGF15GY-BX-L

Quick Summary

Eaton slim GFCI receptacle is a 15A, 125V ground-fault protection device designed for compact spaces and fast installations. Installing bulky outlets in tight panels or retrofit enclosures often leads to wiring challenges and longer project timelines. Certified cULus Listed and NOM, this unit also features tamper-resistant construction and a self-test function to help meet evolving safety codes. The slim form factor, back- and side-wiring capability, and standard NEMA 5-15R configuration deliver reliable protection while reducing conduit congestion and operational risk. For procurement teams, the retail-box packaging and standard 14-10 AWG wiring simplify stocking, sourcing, and field installation without sacrificing safety or compliance.

Product Information

Extended Description

TRGF15GY-BX-L Eaton: Eaton tamper-resistant, self-test GFCI, 15A, 125V, Gray, Slim design, Retail box
Product Name
Eaton slim GFCI receptacle
Catalog Number
TRGF15GY-BX-L
UPC
032664007934
Product Length/Depth
1.03 in
Product Height
4.19 in
Product Width
1.69 in
Product Weight
3.9 lb
Warranty
Refer to warranty document.
Certifications
cULus Listed NOM
Special features
Slim design
Type
Self-test
Amperage Rating
15A
Voltage rating
125V
Circuit interrupter type
GFCI
Packaging type
Retail Box
Features
Tamper resistant
Wiring method
Back and side wire
Allowable wire size
#14-10 AWG
NEMA configuration
5-15R
Torque rating
16 lbf-in
Color
Gray
Feature: Slim design enables a space-saving footprint that reduces panel depth and improves airflow in crowded enclosures. Business Impact: Faster, error-free installations and easier retrofits lower labor costs and project lead times. Application: Ideal for compact electrical panels, utility rooms, and retrofit outlets in both commercial and residential settings. Feature: Self-test functionality continuously verifies operational integrity. Business Impact: Minimizes unplanned downtime and strengthens safety compliance by ensuring protection is active without manual checks. Application: Suitable for mission-critical areas where reliability is essential, such as labs and data centers. Feature: Tamper-resistant construction enhances safety in environments with children or heavy equipment. Business Impact: Reduces risk of covert sleeve openings and accidental contact, supporting code compliance. Application: Hotels, classrooms, and public spaces where outlets are frequently accessed. Feature: Back and side wiring with #14-10 AWG capacity offers flexible termination. Business Impact: Streamlines installation by accommodating various wire configurations, improving pull-through efficiency. Application: New builds and renovations in control panels, wall outlets, and equipment enclosures. Feature: NEMA 5-15R configuration provides universal plug compatibility. Business Impact: Simplifies stocking and maintenance with standard plugs, minimizing compatibility issues. Application: Residential and light commercial outlets in kitchens, offices, and corridors. Feature: Slim GFCI in a retail box supports fast procurement and consistent field provisioning. Business Impact: Reduces lead times and procurement overhead while supporting standardized components across projects. Application: Contractor-led installations and multi-site rollouts in commercial properties.

Get a Quick Quote for a Eaton TRGF15GY-BX-L

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton TRGF15GY-BX-L? Enquire Now

FAQs

To install the TRGF15GY-BX-L, power must be off and the existing receptacle removed. Prepare wires #14-10 AWG, trim per required length, then connect conductors to the back and side terminals as permitted by the device. Tighten to the specified torque of 16 lbf-in, verify ground continuity if applicable, and mount securely in the outlet box. The unit’s self-test and tamper-resistant design support ongoing safety post-installation.
The TRGF15GY-BX-L is cULus Listed and NOM certified, indicating compliance with North American electrical codes and regional standards. These certifications help ensure safe operation, reliability, and acceptance in a wide range of facilities. Combined with tamper-resistant construction and self-test features, the receptacle supports NEC-based safety requirements for personal protection and equipment protection in typical commercial and residential environments.
This slim GFCI receptacle is designed for indoor, dry or protected environments. It is not rated for direct exposure to moisture or outdoor wet locations. For areas with humidity or potential water exposure, select a device specifically rated for damp or wet locations and follow local electrical codes for enclosure protection and installation conditions.
Key specs include 15A current rating, 125V voltage rating, and a NEMA 5-15R configuration for standard plug compatibility. Wiring accepts #14-10 AWG, with back and side termination options and a torque rating of 16 lbf-in. The device is tamper-resistant and features self-test functionality to maintain protection without manual checks.
The slim design saves panel space and accelerates retrofits, reducing labor time and mounting complexity. Self-test and tamper-resistant features increase safety and code compliance, lowering maintenance calls. Standard wiring options and retail-box packaging streamline procurement and field provisioning, improving project predictability and ROI in facilities upgrades and new construction.