Eaton GFCI receptacle TRSGFNL15LA provides ground-fault protection for 125 V outlets in residential and commercial spaces. Installers often face nuisance trips or wiring confusion when upgrading older outlets. This model is cULus Listed and supports night-light and self-test functionality for enhanced safety. By combining reliable protection with easy flush mounting and simple back-and-side wiring, it delivers cost-effective reliability for residential and commercial projects, reducing call-backs and maintenance. With compatibility for #14–10 AWG conductors and a 15 A rating, it also supports robust electrical wiring practices in everyday installations.

Product Information

Extended Description

TRSGFNL15LA Eaton: Eaton GFCI receptacle,Nightlight,Tamper resistant,Self-test,#14 - 10 AWG,15A,Residential,Commercial,Flush,125 V,Back and side wire,Light almond,Night light,Brass,Tamper resistant,Polycarbonate,5-15R,Two-pole, three-wire, grounding
Product Name
Eaton GFCI receptacle
Catalog Number
TRSGFNL15LA
UPC
032664743160
Product Length/Depth
2.06 in
Product Height
4.71 in
Product Width
2.86 in
Product Weight
0.413 lb
Certifications
cULus Listed
Device type
Receptacle
Type
Self-test
Amperage Rating
15A
Voltage rating
125V
Circuit interrupter type
GFCI
Contact material
Brass
Features
Nightlight Tamper resistant
Application
ResidentialCommercial
Wiring method
Back and side wire
Allowable wire size
#14 - 10 AWG
NEMA configuration
5-15R
Torque rating
16 lbf-inch
Environmental conditions
Tamper resistant
Mounting method
Flush
Color
Light almond
Combination type
Night light
Face/body material
PVC Polycarbonate
Receptacle type
Two-pole, three-wire, grounding
Feature → Business Impact → Application: Self-test GFCI logic reduces maintenance risk by automatically verifying protection integrity, lowering call-backs and warranty issues for commercial installations. This translates to higher system uptime in busy spaces like kitchens and baths, where outlets are critical. Application: residential and light commercial outlets that require dependable protection with minimal service interruptions. Feature → Business Impact → Application: Night-light capability provides visible guidance during low-light conditions, improving safety and reducing accidental contact in hallways or entries. This supports code-compliant installations where nighttime visibility is a value-add for occupants. Application: hallways, laundry rooms, and entryways in homes and small offices. Feature → Business Impact → Application: Tamper-resistant design discourages child access to live receptacles, lowering risk in family spaces and education facilities. Application: kitchens, living areas, and student housing where safety standards are prioritized. Feature → Business Impact → Application: Back and side wiring with #14–10 AWG capacity enables fast, versatile installation and reduces wire-stripping waste, lowering labor costs on retrofit projects. Application: new builds and retrofits in residential and light commercial settings. Feature → Business Impact → Application: Flush mount with durable PVC/polycarbonate face and brass contacts provides long-term durability and aesthetic integration with various décor and cabinet options. Application: modern residential interiors and commercial spaces requiring a clean, unobtrusive outlet.

Get a Quick Quote for a Eaton TRSGFNL15LA

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton TRSGFNL15LA? Enquire Now

FAQs

The installation begins by turning off power and confirming the box is compatible with a flush-mount GFCI receptacle. Prepare conductors to #14–10 AWG, secure them in the back and side terminals per the device’s torque spec of 16 lbf-in, and mount the unit flush to the wall. Follow the included Eaton installation instructions to test the self-test function after wiring to ensure proper ground fault protection and night-light operation.
This model combines a 15 A, 125 V GFCI with tamper-resistant features and a built-in night-light, addressing safety and convenience needs across spaces like kitchens, bathrooms, hallways, and offices. Its back and side wiring support makes retrofits straightforward, while cULus Listing confirms compliance with applicable safety standards for diverse occupancy environments.
Key specs include 15A amperage, 125V rating, and a NEMA 5-15R configuration. It supports back and side wiring for #14–10 AWG conductors and uses brass contacts. The device mounts flush and provides a two-pole, three-wire grounding setup. Torque for terminals is rated at 16 lbf-in, ensuring secure connections and reliable protection.
Yes. The TRSGFNL15LA is cULus Listed, reflecting compliance with established electrical safety requirements for both residential and commercial installations. Its tamper-resistant design, self-test functionality, and flush-mount capability further support code-compliant installation in everyday settings.
The integrated self-test feature reduces routine maintenance by continuously verifying protection integrity, lowering risk of undetected faults. The night-light improves user safety and navigation in low-light conditions, reducing trip-related service calls and potential incidental damage. Over multiple projects, this can translate to lower maintenance costs and faster, safer installations.