Eaton TRSGFNL15V GFCI receptacle - cULus Listed
Part Number: TRSGFNL15V
Quick Summary
TRSGFNL15V GFCI receptacle provides reliable ground-fault protection with a built-in nightlight for residential and light-commercial wiring. It helps address the challenge of finding outlets that meet code, offer self-test safety, and minimize installation complexity during retrofits or new builds. The unit carries cULus Listed safety certification and tamper-resistant features, with a self-test function that protects occupants without requiring manual checks. Featuring flush mounting and back-and-side wiring, it supports fast, robust installations while delivering dependable performance. For procurement teams, this means improved safety compliance, reduced rework, and lower lifecycle maintenance costs across projects.
Product Information
Extended Description
TRSGFNL15V Eaton: Eaton GFCI receptacle,Nightlight,Tamper resistant,Self-test,#14 - 10 AWG,15A,Residential,Commercial,Flush,125 V,GFCI,Back and side wire,Ivory,Night light,Brass,Receptacle,Tamper resistant,Polycarbonate,5-15R,Two-pole, three-wire, grounding
Product Name
Eaton GFCI receptacle
Catalog Number
TRSGFNL15V
UPC
032664743177
Product Length/Depth
2.06 in
Product Height
4.71 in
Product Width
2.86 in
Product Weight
0.413 lb
Certifications
cULus Listed
Device type
Receptacle
Type
Self-test
Amperage Rating
15A
Voltage rating
125V
Circuit interrupter type
GFCI
Contact material
Brass
Features
Nightlight Tamper resistant
Application
ResidentialCommercial
Wiring method
Back and side wire
Allowable wire size
#14 - 10 AWG
NEMA configuration
5-15R
Torque rating
16 lbf-inch
Environmental conditions
Tamper resistant
Mounting method
Flush
Color
Ivory
Combination type
Night light
Face/body material
PVC Polycarbonate
Receptacle type
Two-pole, three-wire, grounding
Installing and testing a GFCI receptacle instruction sheet
What is a Ground Fault Circuit Interrupting (GFCI) receptacle?
Eaton Specification Sheet - TRSGFNL15V
Eaton Specification Sheet - TRSGFNL15V
Feature: Nightlight and self-test GFCI provides continuous visibility and automatic safety verification. Business Impact: Enhances user safety and reduces emergency outages by ensuring protection is active without manual testing. Application: Suitable for hallways, kitchens, and commercial spaces where nighttime visibility improves navigation and safety. Feature: Tamper-resistant, two-pole, three-wire grounding design. Business Impact: Improves child protection and code compliance, lowering risk of accidental contact with live conductors. Application: Home renovations and public areas where safety is a regulatory priority. Feature: Back and side wiring for flexible installation with #14–10 AWG conductors. Business Impact: Simplifies retrofits and new installs, reducing labor time and potential wiring errors. Application: New construction and retrofit projects in both residential and light-commercial environments. Feature: Flush mounting with durable PVC/Polycarbonate face and brass contacts. Business Impact: Delivers a clean, durable finish and reliable contact performance, reducing maintenance cycles. Application: Wall outlets in living spaces, offices, and kitchens where aesthetics and longevity matter. Feature: 125V, 15A NEMA 5-15R configuration and 16 lbf-in torque rating. Business Impact: Ensures compatibility with common cords and secure terminations, minimizing call-backs. Application: Standard electrical outlets in homes and small commercial facilities. Feature: cULus Listed certification and residential/commercial applicability. Business Impact: Boosts regulatory confidence, streamlines approvals, and supports safer, compliant deployments across projects.
Get a Quick Quote for a Eaton TRSGFNL15V
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton TRSGFNL15V?
Enquire Now
FAQs
Power off the circuit and remove the existing receptacle. Attach conductors to back and side terminals using #14–10 AWG wire, ensuring secure connections and torque to 16 lbf-in. Mount flush in the wall box, then reinstall the face and test the GFCI with the built-in self-test. Verify the nightlight functions after installation.
The receptacle is 125V, 15A with a NEMA 5-15R configuration. It uses brass contact materials, supports back and side wiring, and accepts #14–10 AWG conductors. The device is designed for two-pole, three-wire grounding and features a self-test function and nightlight.
Yes. The unit is specified for residential and commercial applications, featuring tamper-resistant construction, self-test safety, and a flush-mount design that integrates well in both homes and light commercial spaces, meeting typical code requirements for safety and accessibility.
The TRSGFNL15V is cULus Listed, indicating compliance with U.S. and Canadian safety standards. This certification supports code-friendly installations in both residential and commercial environments and aligns with safety expectations for GFCI outlets with nightlights.
The built-in self-test reduces routine maintenance by continuously verifying protection without manual checks, lowering the risk of undetected faults. Tamper-resistant design and durable materials minimize failure rates, while back/side wiring speeds installation, delivering faster project completion and lower lifecycle costs.