Eaton slim GFCI receptacle TWRGF20LA - cULus Listed
Part Number: TWRGF20LA
Quick Summary
Eaton slim GFCI receptacle provides reliable ground-fault protection for outlets in commercial and industrial spaces. For installers, bulky form factors, weather exposure, and nuisance trips can complicate wiring, maintenance, and uptime. This model is cULus Listed and NOM certified, with FedSpec approved performance to meet critical safety and reliability requirements. Its slim design maximizes enclosure real estate, while the self-test feature reduces manual checks and helps ensure ongoing protection. Designed for 20A, 125V circuits, it accepts #14-10 AWG wiring via back and side terminals, streamlining installation. Ultimately, customers gain faster installs, lower maintenance costs, and stronger code compliance across facilities.
Product Information
Extended Description
TWRGF20LA Eaton: Eaton tamper and weather-resistant, self-test GFCI, 20A, 125V, Light Almond, Slim design
Product Name
Eaton slim GFCI receptacle
Catalog Number
TWRGF20LA
UPC
032664013393
Product Length/Depth
1.03 in
Product Height
4.19 in
Product Width
1.69 in
Product Weight
3.9 lb
Warranty
Refer to warranty document.
Certifications
cULus Listed NOM
Special features
Slim design
Type
Self-test
Amperage Rating
20A
Voltage rating
125V
Circuit interrupter type
GFCI
Packaging type
ED Box
Features
Tamper resistant Weather resistant FedSpec Certified
Wiring method
Back and side wire
Allowable wire size
#14-10 AWG
NEMA configuration
5-20R
Torque rating
16 lbf-in
Color
Light almond
Standard slim GFCI spec sheet
Standard slim GFCI spec sheet
Standard slim GFCI spec sheet
Standard slim GFCI spec sheet
Standard slim GFCI spec sheet
Standard slim GFCI spec sheet
The slim design of the TWRGF20LA saves enclosure space, enabling higher density installations and easier retrofits in crowded control boxes. This translates to shorter wiring runs, faster commissioning, and reduced labor costs on projects with tight enclosure footprints. In practice, space efficiency supports clean cable management and better heat dissipation in busy electrical assemblies. Tamper-resistant and weather-resistant features enhance safety and reliability in real-world environments. By resisting tampering and with protection against moisture exposure, the unit stays functional in damp or outdoor locations, minimizing nuisance failures and field service visits. This combination is particularly valuable for garages, workshops, or exterior panels where protection is critical. Self-test capability and standard 20A at 125V provide strong protection without sacrificing performance. The self-test function helps ensure ongoing operability, while the 5-20R configuration supports common plug loads in commercial and light-industrial settings. Back and side wiring accepts #14-10 AWG conductors with a 16 lbf-in torque, ensuring a secure, code-compliant connection. Wiring versatility and installation convenience drive efficiency. The device uses ED Box packaging and supports back and side wiring, with precise dimensions (1.03 in depth, 4.19 in height, 1.69 in width) that help fit standard electrical boxes and mounting rails. From a procurement perspective, the TWRGF20LA reduces risk with verified certifications (cULus Listed, NOM, FedSpec Certified) and a straightforward installation profile that aligns with existing Eaton GFCI families.
Get a Quick Quote for a Eaton TWRGF20LA
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton TWRGF20LA?
Enquire Now
FAQs
Power off the circuit, then prepare #14-10 AWG conductors for back or side terminals. Connect the wires to the appropriate terminals, tighten to 16 lbf-in torque, and mount the unit in an ED Box instead of a standard device cavity. After wiring, use the self-test feature to verify protection before commissioning.
The TWRGF20LA is cULus Listed and NOM certified, with FedSpec certified performance. These certifications align the device with U.S. and Mexican safety standards, facilitating code compliance in commercial, industrial, and mixed-use facilities and simplifying approval during inspections.
The device is a 20A, 125V GFCI receptacle with a NEMA 5-20R configuration. It supports back and side wiring for #14-10 AWG conductors, and it includes a 16 lbf-in torque rating for secure terminations, along with a self-test function for ongoing safety monitoring.
Yes. The unit is weather-resistant and tamper-resistant, designed to withstand damp environments and exposure typical of exterior panels or garages. Installation in appropriate enclosure types and adherence to local codes are still required to ensure maximum protection in outdoor applications.
The slim design reduces depth to about 1.03 inches, with overall dimensions of roughly 4.19 inches by 1.69 inches. This compact footprint supports higher-density panel layouts, easier retrofits, and improved cable management, which translates to faster installs and better space utilization in crowded control boxes.