Eaton UTE4213CCH Meter Socket - UL Listed
Part Number: UTE4213CCH
Quick Summary
Eaton UTE4213CCH meter socket is a 200A, single‑phase, 3‑wire connection point designed for commercial and light industrial service. This unit addresses common installation challenges such as top/bottom feed placement, ringless mounting, and secure grounding during meter changes. UL Listed certification provides confidence in safety and compliance across a range of utilities and contractors. With a 600 V rating and a lever bypass for fast servicing, it also supports reliable maintenance planning. Built for compatibility with #6-350 kcmil conductors, it helps streamline procurement while delivering consistent electrical performance in demanding environments.
Product Information
Extended Description
UTE4213CCH Eaton: Eaton meter socket, Comm, 200A, Over/under, 5x5 inch hub cover plate, #6-350 kcmil, 4-jaw, 1-ph, #6-350 kcmil, Lever bypass, Gnd conn (#14-#2 Cu), Triplex, 3-wire, Ringless, 600 Vac
Product Name
Eaton meter socket
Catalog Number
UTE4213CCH
UPC
786685351094
Product Length/Depth
4.94 in
Product Height
19 in
Product Width
13 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Type
Commercial
Amperage Rating
200A
Feed type
Top/bottom
Number of jaws
Four-jaw
Phase
Single-phase
Utility approvals
ME : Central Maine Power NM : El Paso Electric TX : El Paso Electric NM : Public Service Company of New Mexico (PNM) WI : WE Energies / Wisconsin Public Service (WPS)
Line
#6-350 kcmil
Load
#6-350 kcmil
Number of wires
Three-wire
Hub type
5 x 5 hub cover plate
Security
Ringless
Voltage rating
600 V
Bypass
Lever
Number of sockets
1
Residential and Light Commercial, Metering Products, Volume 1 Tab 4
Eaton Specification Sheet - UTE4213CCH
Feature → Business Impact → Application: 200A amperage rating enables handling of substantial service loads for commercial buildings, reducing the need for mid‑span upgrades and lowering distribution bottlenecks. This translates to improved uptime and streamlined procurement for projects targeting retail spaces, offices, and light industrial facilities. Feature → Lever bypass and ground connection design → Speeds maintenance while preserving safety and code compliance in daily meter swaps, minimizing downtime during service calls. Application: Ideal for facilities with frequent metering changes or load fluctuations, delivering predictable service continuity. Feature → 5x5 hub cover plate with ringless construction → Simplifies installation and reduces mounting footprint, enabling neater enclosures in constrained electrical rooms. Application: Suitable for retrofit projects and new builds where cabinet space is at a premium. Feature → Top/bottom feed, four‑jaw, three‑wire configuration → Ensures robust, secure conductors and straightforward wiring, supporting #6‑350 kcmil lines and loads for high‑lift distribution. Application: Well‑suited to commercial metering in retail, hospitality, and light industrial installations. Feature → UL Listed, 600 V rating → Provides regulatory assurance and safe operation under common utility voltages, reducing risk and accelerating inspection approvals. Application: Critical for projects with strict safety standards and utility requirements. Feature → Compact footprint with 19 in height and 13 in width → Enables flexible installation in standard electrical rooms, improving space utilization and planning accuracy. Application: Beneficial for retrofit programs and new builds where existing enclosures are size‑constrained.
Get a Quick Quote for a Eaton UTE4213CCH
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton UTE4213CCH?
Enquire Now
FAQs
The UTE4213CCH uses a four‑jaw, ringless design with top/bottom feed capability and supports #6‑350 kcmil conductors on both line and load. It requires a compatible enclosure with a 5x5 hub cover plate and three‑wire service. Ensure grounding conductor (#14‑#2 Cu) is properly connected and follow local code requirements for meter socket clearances and wiring methods.
Key specs include a 200A amperage rating, 600 V voltage rating, single‑phase operation, and three‑wire configuration. The load and line conductors accommodate #6‑350 kcmil, with a lever bypass for service access. These ratings suit mid‑sized commercial loads, enabling reliable service delivery while meeting standard utility and NEC requirements.
Yes. The unit is designed for top/bottom feed, with a four‑jaw socket and ringless construction that simplifies installation in tight enclosures. It supports heavy conductors (#6‑350 kcmil) for substantial service feeds and includes a lever bypass for rapid maintenance, reducing downtime during metering changes in retail, office, and light industrial environments.
The UTE4213CCH is UL Listed, indicating compliance with recognized safety standards for electrical equipment. Its 600 V rating aligns with common commercial service requirements, helping with inspections and approvals across utility and municipal jurisdictions. This certification supports safer procurement, installation, and ongoing operation.
The meter socket’s lever bypass, ringless design, and top/bottom feed reduce service time during metering events, while UL listing and robust conductor support improve reliability and compliance. Together, these features lower maintenance costs, shorten outage restoration times, and improve project ROI by delivering faster commissioning and fewer field complications.