Eaton UTS714D18PZ32 Connector - IP68/69K

Part Number: UTS714D18PZ32
Eaton logo
Manufacturer
Eaton
Part number
UTS714D18PZ32

Quick Summary

The Eaton UTS714D18PZ32 Connector is a rugged plastic waterproof PCB receptacle designed for harsh industrial environments. This solution addresses field failures caused by moisture, dust and vibration by delivering a reliable, sealed connection. Key certifications and standards include IP68/69K protection in unmated conditions, RoHS exemption 6.c, CSA-C22.2 No.182.3, IEC 61984 and UL 1977, reinforcing compliance across critical markets. By combining an 18-pin PCB layout with a robust jam nut receptacle and 1/3 bayonet coupling, it reduces installation time and improves maintenance predictability. In addition to performance, the unit’s compact 25.3 mm depth and 34.9 mm width support space-constrained panel mounting while ensuring long-term reliability for automated equipment and remote sensing applications.

Product Information

Extended Description

UTS714D18PZ32 Eaton: Plastic jam nut receptacle & hold down clips,without backshell, with 18 male PCB contacts, IP68/69K in unmated conditions, keying Z; UTS714D18PZ32
Product Name
Eaton Souriau UTS series plastic waterproof IP68/69k connector
Catalog Number
UTS714D18PZ32
Product Length/Depth
25.3 mm
Product Height
34.9 mm
Product Width
34.9 mm
Product Weight
21.4 g
Compliances
ROHS exemption 6.c CSA-C22.2 No.182.3 (please contact us for more details) IEC 61984 (please contact us for more details) UL 1977 (please contact us for more details)
Current rating
4 A UL 5 A IEC
Environmental conditions
REACH RoHS Flammability rating UL94 HB
Environmental resistance
Resistant against acid bath Resistant against gasoline Vibrations level Per IEC 60512-4 - from 10 to 2000 Hz Resistant against basic bath Resistant against oil Resistant against mineral oil UV resistant, no degradation after 5 years of exposure in natural environment
Test current
4 A CSA 4 A UL 5 A IEC
Test voltage
250 V CSA 50 V IEC 250 V UL
Connector accessory option
No backshell possibility
Connector orientation
Z
Connector type
Receptacle
Contact delivery
Loaded
Contact gender
Pin (Male)
Contact plating
Gold
Contact type
PCB
Coupling type
1/3 Bayonet
Degree of protection
IP68
Insert material
Neoprene
Layout
18
Shell material
Plastic
Shell size
14
Mating cycles
250
Operating temperature - max
105 °C
Operating temperature - min
-40 °C
Receptacle type
Jam Nut Receptacle
Number Of Contacts
18
Number of cavity #20
18
Nut material
Aluminium
Salt spray
500 hour
Feature → Business Impact → Application: IP68/69K rating provides superior water and dust ingress protection, dramatically reducing field failures in wet or dusty environments. This translates to lower maintenance cost and higher uptime for outdoor automation and mining equipment. The 18-pin PCB contact arrangement with gold-plated contacts ensures low contact resistance and stable signal integrity across vibration and temperature extremes, enabling reliable data and power transfer in robotics and conveyor systems. Feature → Business Impact → Application: 1/3 bayonet coupling offers fast, secure mating with straightforward alignment, reducing installation time on assembly lines and in maintenance bays. Application areas include factory automation, material handling and packaging lines where quick, repeatable connections matter. Feature → Business Impact → Application: Jam Nut Receptacle with no backshell option simplifies installation in tight panels, cutting hardware costs while preserving IP sealing; ideal for compact control panels and distributed I/O hubs. Feature → Business Impact → Application: -40 °C to 105 °C operating range and salt spray resistance translate to durable performance in extreme climates or coastal facilities, increasing equipment life and reducing replacement cycles across wind farms, water treatment, or mining operations. Feature → Business Impact → Application: Mating cycles of 250 and aluminum nut with neoprene insert support robust lifecycle performance and sealing; suitable for equipment subject to frequent reconnects, such as test benches and mobile machines. Feature → Business Impact → Application: Compliance with RoHS exemptions and established safety standards (CSA, IEC, UL) reduces regulatory risk and speeds time-to-market for certified assemblies in automotive and industrial sectors.

Get a Quick Quote for a Eaton UTS714D18PZ32

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton UTS714D18PZ32? Enquire Now

FAQs

The UTS714D18PZ32 is a jam nut receptacle with 18 PCB contacts designed for direct PCB mounting. It does not offer a backshell option, which simplifies installation in compact panels but requires careful enclosure sealing at the panel interface. The Z-keying ensures correct orientation, and the 1/3 bayonet coupling provides fast, repeatable mating without a separate backshell.
Current rating is 4 A UL and 5 A IEC, with test current also specified at 4 A CSA/UL and 5 A IEC. Test voltage is 250 V CSA and UL, 50 V IEC. These ratings support reliable power and signal transmission for 18-pin PCB configurations under typical automation loads while maintaining safety margins in industrial environments.
Yes. It carries IP68 protection and remains sealed in unmated conditions, with UV resistance and salt spray endurance (500 hours). Its neoprene insert and plastic shell shrink the risk of ingress in outdoor or wash-down areas, making it suitable for outdoor automation, marine equipment, and coastal installations.
The connector complies with RoHS exemption 6.c and includes CSA-C22.2 No. 182.3, IEC 61984, and UL 1977 compliances. These certifications help ensure regulatory acceptance in North American markets and support safer, certified integration into industrial control systems.
With 250 mating cycles and robust sealing, the UTS714D18PZ32 offers durable field performance with predictable lifecycle cost. Its UV and chemical resistance, combined with aluminium nut and neoprene insert, reduce maintenance frequency and support longer service intervals in harsh environments.