Eaton V48M60T49NV Transformer - UL Listed, DT-3E

Part Number: V48M60T49NV
Manufacturer
Eaton
Part number
V48M60T49NV

Quick Summary

The Eaton V48M60T49NV transformer provides three-phase power for industrial control panels and distribution systems. Engineers struggle with cooling, maintenance, and space constraints in harsh environments. UL Listed certification and a NEMA 3R enclosure ensure safer, compliant operation in indoor and outdoor spaces; the DT-3E design adds rugged field readiness. This 150 kVA, 60 Hz transformer supports precise voltage delivery with a 480 V primary and 600 V secondary, enabling reliable power for critical equipment while enhancing overall system uptime and energy management.

Product Information

Extended Description

V48M60T49NV Eaton: Totally enclosed non-ventilated transformer, DT-3E, Three-phase, Primary voltage: 480V, Taps: 2 at +2.5% FCAN, 4 at -2.5% FCBN, Secondary voltage: 600V, 150°C, 150 kVA, Aluminum windings, FR918AN, 277A, 60 Hz, NEMA 3R
Product Name
Eaton Totally enclosed non-ventilated transformer
Catalog Number
V48M60T49NV
UPC
786680107313
Product Length/Depth
30.68 in
Product Height
62.18 in
Product Width
31.44 in
Product Weight
1545 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Coil material
Aluminum
Design
DT-3E
Enclosure
NEMA 3R
Frame
918AN
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Type
Totally enclosed, non-ventilated transformer
Wiring connection
277A
Frequency rating
60 Hz
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
600 V
Temperature rise
150 °C rise
Volt ampere rating
150 kVA
Weathershield
Indoor-Outdoor
Totally enclosed, non-ventilated DT-3E design minimizes dust ingress and cooling needs, reducing maintenance and extending service intervals. The business impact is lower lifecycle costs and higher equipment availability, especially in harsh environments where ventilation is impractical. In application, this makes the V48M60T49NV ideal for machine control panels and distribution subsystems that require dependable performance with minimal enclosure cooling.

Get a Quick Quote for a Eaton V48M60T49NV

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton V48M60T49NV? Enquire Now

FAQs

For proper installation, ensure clearance for access and cooling, mount within a NEMA 3R rated enclosure, and provide adequate support for the 918AN frame. Plan for the 277 A wiring connection and utilize the +2.5% / -2.5% taps to correct voltage during startup or line fluctuations. Outdoor or indoor locations must align with the indoor-outdoor Weathershield capability.
Key specs include a 150 kVA rating, 60 Hz frequency, three-phase operation, 480 V primary, 600 V secondary, aluminum windings, and a DT-3E design with a NEMA 3R enclosure. The transformer supports 277 A full-load current and provides 2 taps at +2.5% FCAN and 4 taps at -2.5% FCBN for voltage regulation.
Yes. The 480 V to 600 V secondary configuration, paired with DT-3E enclosure and UL Listed safety, makes it well-suited for panel boards, process controls, and machine tooling. The 150 kVA rating provides ample headroom for balanced three-phase loads, while the taps allow voltage fine-tuning under fluctuating supply conditions.
The unit carries UL Listed safety certification and uses a NEMA 3R enclosure, enabling both indoor and outdoor installations. This combination supports compliance with safety standards while providing weather-resistant operation in mixed environments and helping mitigates risks in harsh facilities.
The product ships with Eaton’s warranty policy: one year from installation or eighteen months from shipment, whichever comes first. Routine maintenance includes checking terminal connections, inspecting the enclosure for seals, and verifying cooling pathways remain unobstructed. The non-ventilated design reduces cooling-related maintenance compared with ventilated designs.