Eaton X25M31T1516NON Harmonic Transformer - DOE2016

Part Number: X25M31T1516NON
Manufacturer
Eaton
Part number
X25M31T1516NON

Quick Summary

Eaton Harmonic mitigating transformer reduces harmonic distortion in three-phase power systems used in manufacturing and automation. It delivers clean, stable voltage to sensitive equipment, improving uptime and extending equipment life. Uncorrected harmonics drive higher losses, heat, and nuisance trips, eroding efficiency and increasing maintenance costs. Key standards underpinning its design include DOE2016 Efficient compliance, a NEMA 2 enclosure for indoor environments, and a 60 Hz rating with NEMA ST-20 sound performance. With this transformer, engineers gain a compact, compliant solution that integrates smoothly into panel boards and automation racks while supporting energy-reduction targets and reliable operation.

Product Information

Extended Description

X25M31T1516NON Eaton: Eaton Harmonic mitigating transformer, DOE 2016, NEMA 2 60 Hz, 220°C, 15 kVA Floor, Three-phase, 0°, 220 Delta V, three-wire, 220Y/127 Vac, four-wire, NEMA ST-20, 2 at +2.5%, 4 at -2.5%, 150°C, 15 kVA, FR939, 211X
Product Name
Eaton Harmonic mitigating transformer
Catalog Number
X25M31T1516NON
UPC
786680247705
Product Length/Depth
17.75 in
Product Height
28 in
Product Width
21.88 in
Product Weight
240 lb
Compliances
DOE2016 Efficient
Certifications
Contact Manufacturer
Catalog Notes
10 CFR Part 431 (2016) Efficient
Coil material
Aluminum
Enclosure
NEMA 2
Frame
939
Insulation
277 °C
Material
Aluminum windings
Mounting
Floor
Tap size
2 at +2.5%, 4 at -2.5%
Type
Energy-efficient type DT-3 harmonic mitigating transformer
Wiring connection
211X
Efficiency
10 CFR Part 431-2016 (DOE 2016)
Frequency rating
60 Hz
Kva Rating
15 kVA
Phase
Three-phase
Phase shift
Primary voltage
220 V
Secondary Voltage
220Y/127 V
Sound Level
NEMA ST-20
Temperature rise
150 °C rise
Volt ampere rating
15 kVA
Modification 1
Electrostatic shield
Weathershield
WS57
Feature: Harmonic mitigation design with DT-3 energy-efficient technology reduces harmonic distortion and associated losses. Business Impact: Lower energy consumption and cooler operation translate to measurable savings and longer equipment life. Application: Ideal for automation panels and production lines where sensitive loads demand clean power. Feature: DOE2016 Efficient compliance and 60 Hz three-phase rating deliver compliant performance with reduced standby losses. Business Impact: Energy cost reduction and easier regulatory alignment across facilities. Application: Manufacturing floors and industrial automation environments seeking green compliance. Feature: Tap changer with 2 at +2.5% and 4 at -2.5% enables voltage regulation to accommodate supply variations. Business Impact: Improved voltage stability reduces equipment stress and trip events. Application: Plants with fluctuating utility voltages or panel-level distribution controls. Feature: Aluminum windings and 277 °C insulation offer robust, long-term reliability. Business Impact: Enhanced durability in demanding environments lowers maintenance intervals. Application: Indoor industrial settings with moderate ambient temperatures. Feature: NEMA 2 enclosure and floor mounting simplify installation and protect against contaminants. Business Impact: Faster deployment, safer operation, and reduced enclosure-related risk. Application: Shop floors, switchgear cabinets, and automation cells. Feature: Electrostatic shield modification and WS57 Weathershield option improve EMI shielding and outdoor readiness. Business Impact: Superior electromagnetic compatibility and broadened installation options. Application: Enclosures near motors, drives, or EMI-sensitive equipment. Feature: 15 kVA rating with primary 220 V and secondary 220Y/127 V supports common plant-level distributions. Business Impact: Flexible integration with existing power architectures, minimizing panel rewiring. Application: Panel boards, MCCs, and automation racks where space is at a premium.

Get a Quick Quote for a Eaton X25M31T1516NON

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton X25M31T1516NON? Enquire Now

FAQs

Consider floor mounting in a protected indoor space, 60 Hz three-phase input, 220 V primary, and 220Y/127 V secondary. Ensure wiring uses 211X connections, and plan for the +2.5% / -2.5% tap adjustments to handle voltage variation. The unit uses a NEMA 2 enclosure for indoor protection and DOE2016 efficiency.
Expect reduced harmonic distortion and lower electrical losses due to the DT-3 energy-efficient design, contributing to cooler operation and improved overall efficiency. The 15 kVA rating supports moderate to large panel loads, with 0° phase shift maintaining compatible power delivery for three-phase systems in automation environments.
Yes. With three-phase 60 Hz operation, 15 kVA capacity, and 220 V primary feeding a 220Y/127 V secondary, the X25M31T1516NON integrates well into automation panels and factory electrical rooms. Indoor NEMA 2 protection and floor mounting support reliable installation in typical manufacturing environments.
The unit complies with DOE2016 Efficient standards for energy performance and features a NEMA ST-20 sound rating. The enclosure is NEMA 2 for indoor protection, and the catalog notes reference 10 CFR Part 431 (2016) Efficient guidelines, aligning with energy-efficiency and safety requirements.
The combination of DOE2016 efficiency and harmonic mitigation reduces energy losses and heat, contributing to lower operating costs and less maintenance downtime. Its electrostatic shield option and robust aluminum windings further reduce EMI and wear, supporting longer service intervals and a favorable ROI in automated facilities.