Eaton X48M28B4516CUNON Harmonic Transformer - DOE2016

Part Number: X48M28B4516CUNON
Manufacturer
Eaton
Part number
X48M28B4516CUNON

Quick Summary

Eaton Harmonic mitigating transformer X48M28B4516CUNON provides clean, reliable power conditioning for industrial facilities. In practice, harmonic distortion, voltage sags, and unexpected outages can degrade drives and shorten equipment life, causing costly downtime. This model aligns with DOE 2016 efficiency standards, is UL Listed, and complies with 10 CFR Part 431 efficiency requirements—all housed in a rugged NEMA 2 enclosure with copper windings for durability. The floor-mount, three-phase design supports 480 V delta primary and 208Y/120 V four-wire secondary, while accurate tap settings at +2.5% and -2.5% help maintain voltage under load. By combining energy efficiency with predictable performance, this transformer reduces operating costs and simplifies compliance for industrial automation, data centers, and manufacturing environments.

Product Information

Extended Description

X48M28B4516CUNON Eaton: Eaton Eaton Harmonic mitigating transformer, CU windings, DOE 2016, NEMA 2, 220°C, 45 kVA, Floor mnt, 3-phase, 0° phase shift, PV: 480V delta, SV: 208Y/120, 4-wire, NEMA ST-20, 2 at +2.5%, 4 at -2.5%, 80°C, 45 kVA
Product Name
Eaton Harmonic mitigating transformer
Catalog Number
X48M28B4516CUNON
UPC
786680197475
Product Length/Depth
24 in
Product Height
43 in
Product Width
30.5 in
Product Weight
474 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
DOE2016 Efficient
Certifications
Contact Manufacturer UL Listed
Catalog Notes
10 CFR Part 431 (2016) Efficient
Coil material
Copper
Enclosure
NEMA 2
Insulation
220 °C
Material
Copper
Mounting
Floor
Tap size
2 at +2.5%, 4 at -2.5%
Type
Energy-efficient harmonic mitigating transformer
Wiring connection
200X
Efficiency
10 CFR Part 431-2016 (DOE 2016)
Frequency rating
60 Hz
Kva Rating
45 kVA
Phase
Three-phase
Phase shift
0 °
Primary voltage
480 V delta
Secondary Voltage
208Y/120 V, four-wire
Sound Level
NEMA ST-20
Temperature rise
80 °C rise
Volt ampere rating
45 kVA
Voltage rating
480 Vac-208Y/120 Vac
Feature: Harmonic mitigating transformer design reduces harmonic currents and voltage distortion → Business Impact: Improves power quality, reduces heat in drives and motors, extends equipment life → Application: Drives, CNC controls, and motor-intensive production lines. Feature: DOE 2016 efficient rating and copper windings with 220 °C insulation → Business Impact: Lower I2R losses, cooler operation, energy savings across the plant → Application: High-load installations with restricted cooling capacity. Feature: 0° phase shift in a three-phase system with 480 V delta primary and 208Y/120 V secondary → Business Impact: Simplified integration with existing infrastructure and stable voltage delivery → Application: Data centers, automation panels, and HVAC systems. Feature: Tap settings of 2 at +2.5% and 4 at -2.5% → Business Impact: Precision voltage regulation under varying load → Application: Plant floors with fluctuating demand. Feature: NEMA 2 enclosure for indoor use and floor mounting → Business Impact: Robust protection and easy installation reduces commissioning time → Application: Industrial facilities, manufacturing floors, and service bays. Feature: Certifications and compliance including UL Listed, 10 CFR Part 431 Efficient, and DOE 2016 alignment → Business Impact: Regulatory peace of mind and smoother audits → Application: Facilities subject to energy and safety standards.

Get a Quick Quote for a Eaton X48M28B4516CUNON

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton X48M28B4516CUNON? Enquire Now

FAQs

This unit is floor-mounted for indoor use with a NEMA 2 enclosure. It supports a 480 V delta primary and 208Y/120 V four-wire secondary, with a 200X wiring connection and tap options of +2.5% and -2.5%. Ensure adequate clearance for cooling, proper ventilation, and alignment with existing three-phase feeders to minimize voltage drop and thermal buildup.
The design mitigates harmonic currents and voltage distortion, reducing total harmonic distortion (THD) and safeguarding sensitive drives and controls. In practice, this translates to lower overheating risk, improved motor life, and more stable control of programmable logic and motion systems.
Key verifications include DOE 2016 energy efficiency compliance, UL Listing for electrical safety, and 10 CFR Part 431 efficiency alignment. These certifications support regulatory compliance, energy performance disclosures, and a smoother procurement and inspection process for regulated facilities.
Common applications include data centers, manufacturing lines with heavy motor loads, HVAC systems, and automation panels. The 480 V to 208Y/120 V configuration supports standard industrial equipment while the copper windings and robust enclosure handle continuous operation in demanding environments.
Expect energy savings from DOE 2016 efficiency, reduced downtime due to improved power quality, and longer equipment life from lower harmonic stress. The UL listing and robust NEMA 2 enclosure simplify maintenance planning, while the unit’s reliable copper winding design minimizes replacement frequency and service interruptions.