Eaton X48M28B49CUEETRNON Harmonic Mitigating Transformer - UL Listed

Part Number: X48M28B49CUEETRNON
Manufacturer
Eaton
Part number
X48M28B49CUEETRNON

Quick Summary

Eaton Harmonic mitigating transformer protects sensitive electrical systems by reducing harmonic distortion in 480 V distribution networks. In real facilities, non-linear loads from drives and power supplies often cause overheating, nuisance trips, and efficiency losses that degrade equipment life. It carries UL Listed certification, includes a Certified Test Report per NEMA TP-1 efficiency standards, and uses copper windings for durability in harsh industrial environments. Designed for three-phase 480 V primary and 208Y/120 V secondary, with a 150 kVA rating, this unit supports critical loads while maintaining power quality. For data centers, manufacturing lines, and commercial facilities, it delivers reliable performance, simplifies compliance, and reduces total cost of ownership through improved efficiency and uptime.

Product Information

Extended Description

X48M28B49CUEETRNON Eaton: Eaton Harmonic mitigating transformer, PV 480V, Taps: 2 at +2.5% /4 at -2.5%, SV 208Y/120V, 80°C rise, 150 kVA, Copper windings, EE, TRNON
Product Name
Eaton Harmonic mitigating transformer
Catalog Number
X48M28B49CUEETRNON
UPC
786680108341
Product Length/Depth
30.68 in
Product Height
62.18 in
Product Width
31.44 in
Product Weight
1800 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Certified Test Report of Standard Production Test (on CMI style), NEMA TP-1 efficient
Coil material
Copper
Enclosure
NEMA 2
Frame
918A
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Type
Harmonic mitigating, dry type distribution transformer
Wiring connection
200X
Frequency rating
60 Hz
Phase
Three-phase
Phase shift
0 °
Primary voltage
480 V
Secondary Voltage
208 Y/120 V
Temperature rise
80 °C rise
Volt ampere rating
150 kVA
Special features
Electrostatically shielded
Weathershield
WS34
Harmonic mitigation design reduces harmonic distortion and stabilizes current draw under nonlinear loads. This improves power quality, lowers THD, and reduces overheating risk across downstream equipment. Application: manufacturing lines and facilities with drives, UPS, and non-linear power supplies benefit from steadier voltage and longer asset life. High-capacity performance at 150 kVA with 480 V primary and 208Y/120 V secondary provides reliable feeder protection. Business impact: a single transformer can feed multiple critical loads with consistent voltage, reducing voltage sags and avoided downtime. Application: data centers, distribution feeders, and large commercial spaces. Copper windings and an 80 °C rise rating deliver durability and efficiency in rugged environments. Impact: copper windings offer lower resistance losses and better thermal performance, extending service life. Application: industrial plants where ambient temperatures and continuous operation are common. Tap changer with two +2.5% and four -2.5% taps enables precise voltage compensation for fluctuating input. Impact: maintains secondary voltage within tolerance, reducing equipment stress and improving process stability. Application: long feeders or sites with variable supply voltages. Electrostatic shielding and Weathershield WS34 add EMI protection and weather resilience. Impact: minimizes interference with control systems and protects against harsh outdoor or dusty indoor conditions. Application: outdoor installations or plant floors with dust and moisture exposure. Rugged enclosure and standards alignment ease installation. The unit is a dry-type, three-phase transformer in a NEMA 2 enclosure with a 918A frame and 200X wiring connection, weighing about 1800 lb. Impact: simplifies crane and rigging planning, accelerates commissioning, and reduces downtime across capital projects.

Get a Quick Quote for a Eaton X48M28B49CUEETRNON

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton X48M28B49CUEETRNON? Enquire Now

FAQs

Plan for craneable handling due to an approximate 1800 lb weight, secure 480 V three-phase input with 60 Hz supply, and mount in a NEMA 2 enclosure. Ensure 200X wiring connections are properly routed, allow clearance for access, and follow manufacturer torque specs for taps. Use the +2.5% and -2.5% tap settings to compensate for voltage fluctuations at the site.
The device is engineered as a harmonic mitigating transformer, which attenuates harmonic currents from nonlinear loads, reducing THD and stabilizing voltages. Copper windings and precise tap control minimize losses and heat, while UL Listed certification confirms safety and reliability for industrial environments with drives and nonlinear power equipment.
Yes. With a 150 kVA rating, 480 V primary and 208Y/120 V secondary, and a three-phase 60 Hz profile, it cleanly feeds critical loads while mitigating harmonics. Features like electrostatic shielding and the WS34 weather shield option improve EMI protection and environmental resilience, making it well suited for data centers and heavy manufacturing applications.
The unit is UL Listed and catalog notes reference NEMA TP-1 efficiency. It features an 80 °C rise rating, copper windings, a NEMA 2 enclosure, and a 918A frame. The product also includes a Certified Test Report and a durable electrostatic shield, aligning with typical industrial compliance requirements.
Expect lower maintenance needs due to a dry-type design and robust copper windings that resist thermal stress. Eaton provides a one-year warranty from installation or 18 months from shipment, whichever occurs first. ROI benefits come from improved power quality, reduced downtime, and longer asset life in facilities with nonlinear loads and critical processes.