Eaton Harmonic X48M28F30CUEEP2NON Transformer - NEMA TP-1
Part Number: X48M28F30CUEEP2NON
Quick Summary
Eaton Harmonic mitigating transformer delivers clean power quality for critical loads in industrial automation. Nonlinear loads create harmonic currents that stress feeders, degrade sensor accuracy, and shorten equipment life. UL Listed and NEMA TP-1 compliant, this transformer combines safety with efficiency for demanding facilities. Designed for data centers, manufacturing lines, and control panels, it supports reliable power distribution while reducing operating costs.
Product Information
Extended Description
X48M28F30CUEEP2NON Eaton: Eaton Harmonic mitigating transformer, PV 480V, Taps: 2 at +2.5% /4 at -2.5%, SV 208Y/120V, 115°C rise, 30 kVA, Copper windings, EE, P2NON
Product Name
Eaton Harmonic mitigating transformer
Catalog Number
X48M28F30CUEEP2NON
UPC
786680072475
Product Length/Depth
16.5 in
Product Height
30 in
Product Width
23 in
Product Weight
460 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA TP-1 Compliant
Certifications
UL Listed
Catalog Notes
NEMA TP-1 efficient, 80kA per phase SPD on Primary w/o indicator light
Coil material
Copper
Frame
912B
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Type
Dry Type Distribution Transformer
Wiring connection
200X
Frequency rating
60 Hz
Phase
Three-phase
Phase shift
0 °
Primary voltage
480 V
Secondary Voltage
208 Y/120 V
Temperature rise
115 °C rise
Volt ampere rating
30 kVA
Special features
Electrostatically shielded
Weathershield
WS38
Commercial Distribution, Transformers, Volume 2, Tab 2
Eaton Specification Sheet - X48M28F30CUEEP2NON
The harmonic-mitigating design lowers total harmonic distortion on 480 V to 208Y/120 V feeds, reducing neutral currents and insulation losses across the distribution network. This translates to improved downstream voltage stability and longer equipment life, which is particularly valuable for automated machinery and sensitive controls in data centers and manufacturing floors. Voltage taps provide on-site regulation with two taps at +2.5% and four taps at -2.5%, enabling precise compensation for supply swings and tighter voltage bands at critical loads, reducing trip risk and sensor drift. The unit includes electrostatic shielding and WS38 weather shielding for EMI protection and environmental resilience, extending life in challenging plant environments and contributing to lower maintenance costs. With a 30 kVA rating and copper windings in a dry-type construction, installation remains straightforward in typical equipment rooms, with robust short-circuit withstand and dependable long-term performance. UL Listed and NEMA TP-1 compliant design, along with documented efficiency notes, support compliance programs and energy-management objectives across facilities needing reliable power conditioning.
Get a Quick Quote for a Eaton X48M28F30CUEEP2NON
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton X48M28F30CUEEP2NON?
Enquire Now
FAQs
Plan for a three-phase indoor/outdoor installation with a 912B frame footprint and a 16.5 in depth, 23 in width, and 30 in height. Ensure adequate clearance for the WS38 weather shield and ventilation, and verify compatibility with 200X wiring. Confirm supply is 480 V primary and that downstream equipment can operate at 208Y/120 V to avoid voltage mismatch.
The transformer reduces total harmonic distortion in the feed, lowering neutral currents and insulating losses. This leads to cooler operation for downstream drives and sensors, reduces thermal stress on transformers and cables, and improves long-term reliability of power-intensive equipment and control systems.
Yes. The unit is UL Listed for safety and NEMA TP-1 compliant for efficiency and performance in industrial power distribution. This combination supports safety mandates, installation approvals, and compliance reporting for regulated facilities.
The transformer provides taps at +2.5% (two taps) and -2.5% (four taps). Use these to compensate for feeder voltage drops or rises, selecting taps that keep downstream 208Y/120 V loads within tolerance. This reduces nuisance tripping and improves sensor accuracy on critical loads.
With a 30 kVA rating, copper windings, and a dry-type build, maintenance is minimal and predictable. UL/NEMA TP-1 certification supports compliance, and voltage regulation reduces downtime and energy waste. The combination of improved power quality and protection features typically yields savings through longer equipment life and fewer unplanned outages.