Eaton X48M28T1516NON Harmonic Transformer - DOE 2016
Part Number: X48M28T1516NON
Quick Summary
Eaton harmonic mitigating transformer delivers clean power quality for industrial facilities with sensitive loads. This solution targets the common pain of harmonic distortion that leads to overheating, reduced equipment life, and noncompliance risk in manufacturing environments. DOE 2016 Efficient compliance, a rugged NEMA 2 enclosure, and a 60 Hz, three-phase design underpin reliable operation across floors in harsh settings. By integrating robust low-voltage distribution with precise tap settings, this transformer supports energy efficiency and consistent voltage regulation. In practice, it strengthens your power-management strategy while remaining compatible with 480 V to 208Y/120 V systems and floor-mounted installations. This makes it a strong fit for industrial plants, data centers, and machine shops seeking dependable harmonic mitigation and cost reduction.
Product Information
Extended Description
X48M28T1516NON Eaton: Eaton Harmonic mitigating transformer, DOE 2016, NEMA 2 60 Hz, 220°C, 15 kVA Floor, Three-phase, 0°, 480 Delta V, three-wire, 208Y/120 Vac, four-wire, NEMA ST-20, 2 at +2.5%, 4 at -2.5%, 150°C, 15 kVA, 480 Vac-208Y/120 Vac
Product Name
Eaton Harmonic mitigating transformer
Catalog Number
X48M28T1516NON
UPC
786680177415
Product Length/Depth
17.75 in
Product Height
28 in
Product Width
21.88 in
Product Weight
237 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
DOE2016 Efficient
Certifications
Contact Manufacturer
Catalog Notes
10 CFR Part 431 (2016) Efficient
Coil material
Aluminum
Enclosure
NEMA 2
Frame
939
Insulation
220 °C
Material
Al windings
Mounting
Floor
Tap size
2 at +2.5%, 4 at -2.5%
Type
Energy-efficient type DT-3 harmonic mitigating transformer
Wiring connection
200X
Efficiency
10 CFR Part 431-2016 (DOE 2016)
Frequency rating
60 Hz
Kva Rating
15 kVA
Phase
Three-phase
Phase shift
0 °
Primary voltage
480 V
Secondary Voltage
208Y/120 V
Sound Level
NEMA ST-20
Temperature rise
150 °C rise
Volt ampere rating
15 kVA
Voltage rating
480 Vac-208Y/120 Vac
Modification 1
Electrostatic shield
Weathershield
WS57
Eaton's low-voltage dry-type distribution transformers
Eaton's low-voltage dry-type distribution transformers
Eaton Specification Sheet - X48M28T1516NON
Feature: Harmonic mitigating design reduces total harmonic distortion and improves power quality. Business Impact: Lower transformer heating, reduced thermal stress on downstream equipment, and improved overall system efficiency. Application: Ideal for manufacturing floors and data centers with heavy nonlinear loads. Feature: DOE 2016 Efficient compliance and 10 CFR Part 431 alignment. Business Impact: Helps facilities meet regulatory energy targets and reduce operating costs through verified energy savings. Application: Compliance-driven environments where energy performance is critical. Feature: NEMA 2 enclosure with floor mounting. Business Impact: Durable, weather-resistant protection suitable for indoor, dirty, and dusty environments; easy integration into existing floorspace. Application: Plant floors, electrical rooms, and retrofit sites requiring rugged enclosure protection. Feature: 15 kVA three-phase transformer with 480 V primary and 208Y/120 V secondary. Business Impact: Scalable power handling with stable voltage conversion for sensitive loads; minimizes voltage fluctuation during startup or peak demand. Application: Medium-load data centers, drives, and automation panels. Feature: Tap size options – 2 at +2.5%, 4 at -2.5%. Business Impact: Precise voltage regulation under varying load conditions; reduces risk of undervoltage/overvoltage events. Application: Sites with fluctuating supply voltages or long feeder runs. Feature: Aluminum windings, electrostatic shield, 200X wiring connection. Business Impact: Enhanced thermal performance, durability, and insulation reliability; simplified maintenance. Application: Harsh industrial environments requiring robust construction. These features align with long-tail keywords such as harmonic mitigating transformer, 15 kVA transformer, 480 V to 208Y/120 V, DOE 2016 efficiency, NEMA 2 enclosure, floor-mounted transformer, and aluminum windings to support installation efficiency and compliance while delivering measurable efficiency gains.
Get a Quick Quote for a Eaton X48M28T1516NON
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton X48M28T1516NON?
Enquire Now
FAQs
For installation, plan floor mounting in a protected indoor space with a stable surface. The unit uses a 200X wiring connection and offers a 15 kVA rating with a 480 V primary and 208Y/120 V secondary. Utilize the +2.5% / -2.5% tap settings to maintain voltage during load and supply variations, ensuring proper clearance and ventilation for aluminum windings.
The X48M28T1516NON is designed as an energy-efficient harmonic mitigating transformer, delivering reduced harmonic distortion and improved power quality at 60 Hz. Its electrostatic shield and aluminum windings enhance electrical performance and reliability, helping downstream equipment operate cooler and more efficiently while meeting DOE 2016 requirements.
Yes. The unit complies with DOE 2016 efficiency requirements and is designed to align with 10 CFR Part 431 (2016) efficiency guidelines. It also features a rugged NEMA 2 enclosure suitable for indoor industrial environments, supporting reliable operation in typical factory settings.
Applications include data centers, manufacturing plants, and machine automation using nonlinear loads such as motor drives and power electronics. The 480 V to 208Y/120 V configuration, three-phase design, and 15 kVA rating make it ideal for mid-range power distribution with robust harmonic mitigation and precise voltage regulation.
Warranty is Eaton Selling Policy 25-000, covering one year from installation or eighteen months from shipment, whichever occurs first. For ongoing reliability, follow standard preventative maintenance schedules, monitor voltage taps, inspect enclosure and insulation, and verify that the electrostatic shield remains intact. Customer support and parts availability are provided by Eaton as part of their power-management portfolio.