Eaton X48M28T2216CUNON Harmonic Transformer - UL Listed

Part Number: X48M28T2216CUNON
Manufacturer
Eaton
Part number
X48M28T2216CUNON

Quick Summary

Eaton Harmonic mitigating transformer delivers efficient power conditioning for data centers and manufacturing lines. Nonlinear loads create harmonics that raise losses, trigger overheating, and shorten motor and transformer life. This unit meets DOE 2016 efficiency targets and is UL Listed, with a rugged NEMA 2 enclosure for reliable indoor service. Designed for three-phase 480 V input and 208Y/120 V output, it supports floor-mount installations in busy plant environments. With copper windings and selectable taps, it adapts to variable loads while staying compliant with industry norms, delivering lower total cost of ownership.

Product Information

Extended Description

X48M28T2216CUNON Eaton: Eaton Harmonic mitigating transformer, DOE 2016, NEMA 2, FR943, 60 Hz, 220°C, 225 kVA Floor, Three-phase, 0°, 480 Delta V, three-wire, 208Y/120 Vac, four-wire, NEMA ST-20, 2 at +2.5%, 4 at -2.5%, 150°C, 225 kVA, 480 Vac-208Y/120 Vac
Product Name
Eaton Harmonic mitigating transformer
Catalog Number
X48M28T2216CUNON
UPC
786680232244
Product Length/Depth
33.5 in
Product Height
60 in
Product Width
38 in
Product Weight
2597 lb
Compliances
DOE2016 Efficient
Certifications
UL Listed
Catalog Notes
10 CFR Part 431 (2016) Efficient
Coil material
Copper
Enclosure
NEMA 2
Frame
FR944
Insulation
220 °C
Material
Copper windings
Mounting
Floor
Tap size
2 at +2.5%, 4 at -2.5%
Type
Energy-efficient harmonic mitigating transformer
Wiring connection
200X
Efficiency
10 CFR Part 431-2016 (DOE 2016)
Frequency rating
60 Hz
Kva Rating
225 kVA
Phase
Three-phase
Phase shift
0 °
Primary voltage
480 V
Secondary Voltage
208Y/120 V
Sound Level
NEMA ST-20
Temperature rise
150 °C rise
Volt ampere rating
225 kVA
Voltage rating
480 Vac-208Y/120 Vac
Weathershield
WS61
DOE 2016 efficiency and UL Listed safety define the core specification of this transformer. The energy-efficient design minimizes line losses, lowers operating heat, and reduces lifetime energy costs for facilities with nonlinear loads. It is ideal for floor-mounted installations in data centers and manufacturing lines where reliability and safety cannot be compromised. Selectable taps (+2.5% on two taps, and -2.5% on four taps) allow precise voltage tuning under varying load and input conditions. The result is steadier 208Y/120 V secondary output, reduced voltage stress on downstream equipment, and fewer nuisance trips during voltage sags. This is particularly valuable in multi‑supplier power environments and when feeding sensitive drives or PLCs. Three-phase 480 V primary to 208Y/120 V secondary with copper windings delivers robust electrical performance and high efficiency. The copper windings offer excellent thermal and electrical conductivity, enabling consistent voltage regulation and long service life. The FR944 frame and 200X wiring connection support straightforward mounting and connection to standard plant power rails. Rugged NEMA 2 enclosure and 60 Hz operation withstand typical indoor plant conditions. The 220 °C insulation and 150 °C rise ensure safe operation under peak loads, while floor mounting and the FR944 frame simplify site integration. Compliance and documentation streamline procurement and maintenance. DOE2016 efficient standard and UL Listing provide regulatory confidence, while catalog notes reference 10 CFR Part 431 (2016) Efficient. These factors support predictable ROI by reducing energy waste and extending equipment life in continuous-operation environments. Copper-wind coil transformers offer measurable gains in reliability when paired with modern harmonics mitigation strategies. For facilities expanding capacity or modernizing legacy systems, this model provides a straightforward upgrade path without rewiring, facilitating quick installations and consistent performance.

Get a Quick Quote for a Eaton X48M28T2216CUNON

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton X48M28T2216CUNON? Enquire Now

FAQs

The installation uses a floor-mounted FR944 frame with copper windings and a 200X wiring connection. Connect the primary to a 480 V delta source, configure the taps for +2.5% or -2.5% as needed, and connect the secondary to 208Y/120 V loads. Ensure a NEMA 2 enclosure sits in a protected indoor location and follow standard plant electrical practices to maintain system integrity.
The X48M28T2216CUNON is designed for DOE2016 Efficient performance and UL safety certification, delivering reduced losses and improved harmonic mitigation in nonlinear-load environments. Expect improved energy efficiency, lower heat rise, and better voltage regulation across typical plant operating conditions, translating to lower operating costs and extended equipment life.
Yes. Its energy-efficient, harmonic-mitigating design targets nonlinear harmonics common in data centers and modern manufacturing. With a 225 kVA rating, 480 V input, and 208Y/120 V output, it supports critical loads like drives, PLCs, and IT infrastructure while maintaining power quality and system reliability.
The transformer is UL Listed and DOE2016 Efficient compliant, with 10 CFR Part 431 (2016) Efficient notes. It features a NEMA 2 enclosure suitable for indoor use, FR944 frame construction, and a 60 Hz rating, ensuring regulatory alignment and performance in standard industrial environments.
By reducing harmonic losses and improving electrical efficiency, the transformer lowers energy costs and minimizes overheating. Its robust enclosure and copper windings support long service life with minimal maintenance, delivering a favorable return on investment in facilities with continuous operation and demanding power quality requirements.