Eaton X48M28T33CUEENON Harmonic Transformer - UL Listed

Part Number: X48M28T33CUEENON
Manufacturer
Eaton
Part number
X48M28T33CUEENON

Quick Summary

The Eaton X48M28T33CUEENON harmonic transformer is designed to mitigate harmonic distortion in three-phase 480 V systems, making it ideal for manufacturing plants and data centers. Facilities wrestle with voltage distortion, equipment nuisance trips, and rising cooling costs caused by unbalanced loads. UL Listed and NEMA TP-1 compliant, this unit meets key safety and efficiency standards for demanding installations. With copper windings and a rugged dry-type construction, it delivers reliable performance at a 300 kVA rating, supporting compact deployment near sensitive equipment. This combination yields improved power quality, lower energy losses, and a clear path to compliant, long-term operation across critical production lines.

Product Information

Extended Description

X48M28T33CUEENON Eaton: Eaton Harmonic mitigating transformer, PV 480V, Taps: 2 at +2.5% /4 at -2.5%, SV 208Y/120V, 150°C rise w/ 200°C insulation systeam, 300 kVA, Copper windings, EE, NON
Product Name
Eaton Harmonic mitigating transformer
Catalog Number
X48M28T33CUEENON
UPC
786680030031
Product Length/Depth
36.23 in
Product Height
75 in
Product Width
44.2 in
Product Weight
3569 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA TP-1 Compliant
Certifications
UL Listed
Catalog Notes
NEMA TP-1 efficient
Coil material
Copper
Frame
919X
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Type
Dry Type Distribution Transformer
Wiring connection
201X
Frequency rating
60 Hz
Phase
Three-phase
Phase shift
0 °
Primary voltage
480 V
Secondary Voltage
208 Y/120 V
Temperature rise
150 °C rise
Volt ampere rating
300 kVA
Special features
Electrostatically shielded
Weathershield
WS35
Feature: Three-phase 480 V primary with a 208Y/120 V secondary; Impact: simplifies distribution design and improves compatibility with common drives and controls; Application: manufacturing lines and data centers. Feature: 300 kVA rating; Impact: supports load growth and reduces the number of transformers needed; Application: mid-size plants with heavy motor loads and drive-based processes. Feature: Tap changer with 2 taps at +2.5% and 4 taps at -2.5%; Impact: maintains secondary voltage under fluctuating loads and line drops; Application: facilities with long feeders or volatile demand. Feature: Copper windings and a dry-type construction rated to a 150 °C rise with a 200 °C insulation system; Impact: delivers high conductivity and robust thermal performance; Application: data centers, automation floors, and process lines with elevated ambient temperatures. Feature: Frame 919X and wiring connection 201X; Impact: supports compact installation and easy integration with standard switchgear; Application: switchgear rooms and controlled machinery spaces. Feature: Electrostatically shielded design and WS35 weathershield provide EMI protection and weather resilience; Impact: enables outdoor or semi-outdoor installation and reduces system interference; Application: outdoor equipment enclosures or harsh industrial sites.

Get a Quick Quote for a Eaton X48M28T33CUEENON

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton X48M28T33CUEENON? Enquire Now

FAQs

This is a dry-type distribution transformer with a 919X frame and 201X wiring connection, designed for indoor use in switchgear rooms or controlled spaces. Plan for adequate clearance, proper ventilation, and routing to 480 V primary and 208Y/120 V secondary circuits. If outdoor exposure is anticipated, consider WS35 Weathershield options and enclosure protection to maintain performance.
The unit offers taps at +2.5% and -2.5% to adjust secondary voltage in response to feeder drops or load swings. This improves voltage regulation, reduces nuisance tripping of sensitive drives, and maintains consistent equipment performance across shifts and equipment starts.
Yes. With a 300 kVA rating and a 480 V to 208Y/120 V secondary, it supports motor drives, control panels, and power-intensive equipment common in data centers and manufacturing floors. Its dry-type construction and copper windings enhance reliability, while the shielded design minimizes EMI in densely packed equipment rooms.
The transformer is UL Listed and NEMA TP-1 compliant, signaling compliance with safety and efficiency standards important for industrial installations. These certifications help meet procurement criteria, support regulatory alignment, and simplify audit processes for regulated facilities and OEM integration.
Warranty is Eaton Selling Policy 25-000, one year from installation or eighteen months from shipment, whichever occurs first. Copper windings and robust dry-type construction contribute to reliable operation with reduced maintenance needs, while the insulated design supports long service life in demanding environments.