Eaton X48M34B33CUEETTNON Harmonic transformer - NEMA TP-1

Part Number: X48M34B33CUEETTNON
Manufacturer
Eaton
Part number
X48M34B33CUEETTNON

Quick Summary

Eaton harmonic mitigating transformer provides filtered power quality for commercial and industrial PV and distribution systems. It helps facilities address harmonic distortion that can stress motors, trip breakers, and reduce efficiency under heavy loads. UL Listed, NEMA TP-1 compliant, and rated for an 80 °C rise, this dry-type transformer also features copper windings and built-in thermal indicators for reliable operation in challenging environments. As a dry-type EE core distribution solution, it delivers compact footprint and straightforward installation while meeting safety and efficiency standards. By aligning with power quality objectives and compliance requirements, it supports reduced maintenance costs and longer equipment life in industrial environments. Secondary benefits include compatibility with 480 V/400Y-231 V systems and scalable taps for voltage control.

Product Information

Extended Description

X48M34B33CUEETTNON Eaton: Eaton Harmonic mitigating transformer, PV 480V, Taps: 2 at +2.5% /4 at -2.5%, SV 400Y/231V, 80°C rise, 300 kVA, Copper windings, EE, TTNON
Product Name
Eaton Harmonic mitigating transformer
Catalog Number
X48M34B33CUEETTNON
UPC
786680057175
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
0.001 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA TP-1 Compliant
Certifications
UL Listed
Catalog Notes
NEMA TP-1 efficient, Two thermal indicators embedded in center coil
Coil material
Copper
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Type
Dry Type Distribution Transformer
Frequency rating
60 Hz
Phase
Three-phase
Phase shift
0 °
Primary voltage
480 V
Secondary Voltage
400 Y/231 V
Temperature rise
80 °C rise
Volt ampere rating
300 kVA
Special features
Electrostatically shielded
Harmonic mitigation design reduces current distortion by filtering out harmonic components generated by nonlinear loads, improving system power factor and reducing heat losses. This translates to lower maintenance costs, longer motor life, and fewer nuisance tripping events, particularly in facilities with high non-linear load such as drives and inverters. Copper windings and an 80 °C rise rating deliver high reliability and robust performance in warm spaces or confined plant rooms, supporting longer service life and reduced cooling requirements. The transformer’s taps, +2.5% and -2.5% (2 and 4 taps respectively), enable precise voltage regulation to compensate for supply variation and loading, minimizing voltage fluctuations that can damage sensitive equipment. UL Listed and NEMA TP-1 compliant certifications, along with center-coil thermal indicators and electrostatic shielding, bolster compliance, EMI control, and safety in critical environments like data centers and hospitals. The 480 V primary and 400Y/231 V secondary in a three-phase, 60 Hz configuration offer a practical, scalable solution for modern distribution schemes, while the dry-type EE core design supports straightforward indoor installation and reduced footprint. Overall, the product combines industry-standard ratings with practical features to ease procurement, installation, and ongoing maintenance in industrial facilities.

Get a Quick Quote for a Eaton X48M34B33CUEETTNON

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton X48M34B33CUEETTNON? Enquire Now

FAQs

Begin by confirming the 480 V primary and 400Y/231 V secondary ratings and ensure the switchgear can accommodate a 300 kVA, three-phase unit. Connect the high-voltage primary to the 480 V bus, and wire the secondary to the 400Y/231 V load with the correct grounding. Utilize the device’s two taps (+2.5% and -2.5%) to fine-tune voltage under load changes. Verify center-coil temperature indicators and electrostatic shielding are intact for safe operation, and comply with UL Listed and NEMA TP-1 requirements during commissioning.
Key specifications include a 300 kVA rating, 60 Hz frequency, three-phase configuration, 480 V primary, 400Y/231 V secondary, and zero phase shift (0°). It uses copper windings and an EE dry-type core with an 80 °C rise, plus taps at +2.5% and -2.5% for voltage adjustment. It is UL Listed and NEMA TP-1 compliant, with embedded thermal indicators in the center coil to monitor operating temperature and reliability.
Yes. Its harmonic mitigating design helps manage distortion from nonlinear PV inverters and other equipment common in data centers. The 480 V to 400Y/231 V output suits many building distribution schemes, while UL Listed and NEMA TP-1 compliance support safety and regulatory requirements in critical facilities. The device’s compact dry-type EE core and copper windings offer reliable performance in indoor spaces typical of these applications.
The unit is UL Listed, satisfying recognized safety standards for electrical equipment, and NEMA TP-1 compliant, ensuring efficiency targets and performance within industry guidelines. These certifications, along with electrostatic shielding and center-coil thermal indicators, provide regulatory assurance, EMI control, and easier acceptance in regulated facilities such as healthcare, data centers, and industrial plants.
Maintenance is typically low for a dry-type transformer with copper windings, due to solid insulation and minimal cooling requirements. The embedded thermal indicators simplify thermal monitoring, and the 80 °C rise rating provides resilience in warmer spaces. ROI is enhanced by improved power quality, reduced harmonic losses, longer motor life, and fewer nuisance trips, which collectively lower maintenance costs and downtime in capital-intensive facilities.