Eaton X48M34B49CUEETTTHR Harmonic Transformer - UL Listed

Part Number: X48M34B49CUEETTTHR
Manufacturer
Eaton
Part number
X48M34B49CUEETTTHR

Quick Summary

The Eaton harmonic mitigating transformer suppresses harmonics in three-phase 480 V systems for data centers, manufacturing lines, and PV installations. Harmonic distortion can raise heating in equipment, distort voltages, and complicate compliance reporting—this design targets those challenges. UL Listed and NEMA TP-1 compliant, with two embedded thermal indicators, it meets safety and energy-efficiency expectations. By delivering a reliable 150 kVA rating with copper windings and adjustable taps, it supports dependable power quality for mission-critical loads. The product’s rugged dry-type construction suits indoor and outdoor environments with WS34 weather shield options. With 60 Hz operation, phase shift of -30 degrees, and flexible tap settings, customers gain precise voltage regulation and system resilience.

Product Information

Extended Description

X48M34B49CUEETTTHR Eaton: Eaton Harmonic mitigating transformer, PV 480V, Taps: 2 at +2.5% /4 at -2.5%, SV 400Y/231V, 80°C rise, 150 kVA, Copper windings, EE, TTTHR
Product Name
Eaton Harmonic mitigating transformer
Catalog Number
X48M34B49CUEETTTHR
UPC
786680058516
Product Length/Depth
30.68 in
Product Height
62.18 in
Product Width
31.44 in
Product Weight
2325 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA TP-1 Compliant
Certifications
UL Listed
Catalog Notes
NEMA TP-1 efficient, Two thermal indicators embedded in center coil
Coil material
Copper
Frame
918A
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Type
Dry Type Distribution Transformer
Wiring connection
203X
Frequency rating
60 Hz
Phase
Three-phase
Phase shift
-30 °
Primary voltage
480 V
Secondary Voltage
400 Y/231 V
Temperature rise
80 °C rise
Volt ampere rating
150 kVA
Special features
Electrostatically shielded
Weathershield
WS34
Harmonic mitigation is engineered into the core design, reducing THD and smoothing voltage waveforms for sensitive loads. The result is lower transformer heating, improved efficiency, and extended equipment life in critical applications. This makes it ideal for data centers, PV inverters, and high-demand manufacturing lines where power quality directly affects uptime. The transformer offers taps at +2.5% and -2.5% to compensate voltage drop along feeders and during loading transients, translating to tighter voltage regulation at the load end and reducing nuisance trips. It’s particularly valuable in facilities with long distribution runs or varying supply quality. Copper windings and an 80°C rise rating indicate robust construction and thermal performance, delivering dependable operation in challenging environments. The dry-type insulation facilitates safer installation in occupied spaces and supports conservative maintenance planning. Two embedded thermal indicators enable quick visual checks, supporting proactive maintenance and minimized outages. The 150 kVA rating complements this by enabling scalable load growth without equipment replacement. Compliance and protection features include UL Listed certification, NEMA TP-1 efficiency considerations, and a WeatherShield option WS34 for outdoor installations. These attributes reduce regulatory risk and simplify project compliance. Easy integration is aided by a 203X wiring connection and a standard footprint, easing field installation and future upgrades. Dimensions (approximate) and weight inform mounting decisions for concrete pads or enclosures in constrained spaces.

Get a Quick Quote for a Eaton X48M34B49CUEETTTHR

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton X48M34B49CUEETTTHR? Enquire Now

FAQs

Plan for a three-phase, 480 V feed using the 203X wiring connection. Verify clearances and mounting accommodating the unit’s dimensions (30.68 in L x 62.18 in H x 31.44 in W) and weight (≈2325 lb). Use the WS34 weather shield option for outdoor or exposed installations. Incorporate the +2.5% and -2.5% taps to stabilize feeder voltage during load changes and perform routine thermal monitoring via embedded indicators.
The transformer is rated 150 kVA with a 480 V primary and a 400Y/231 V secondary. It operates at 60 Hz in a three-phase configuration with a phase shift of -30 degrees. It uses copper windings and has an 80°C rise rating. It’s UL Listed and NEMA TP-1 compliant, designed for efficient, reliable operation in demanding environments.
Yes. Its harmonic mitigation reduces THD, improving power quality for sensitive electronics in data centers and PV inverters, while the robust copper windings and strict compliance support continuous manufacturing operations. The adjustable taps help maintain stable voltage, minimizing downtime and equipment wear.
Two primary considerations are UL Listed certification for safety and NEMA TP-1 efficiency compliance. The unit also holds a NEMA TP-1 efficient design, with dual embedded thermal indicators for ongoing monitoring. For outdoor deployments, WS34 WeatherShield enhances protection against environmental factors.
Warranty coverage follows Eaton policy 25-000: one year from installation or eighteen months from shipment, whichever occurs first. For service and documentation, refer to Eaton’s Selling Policy and the provided datasheets and specification sheets to support maintenance planning and ROI tracking.