Eaton Y60M28T75A Transformer - UL Listed, 75 kVA

Manufacturer
Eaton
Part number
Y60M28T75A

Quick Summary

Eaton Y60M28T75A is a general-purpose encapsulated transformer designed for three-phase power distribution in industrial facilities. This rugged unit helps address voltage stability and space constraints that can disrupt uptime. Key certifications and ratings include UL Listed and a NEMA 3R enclosure for versatile indoor-outdoor service, plus a 115°C rise for demanding environments. By combining aluminum windings with a robust enclosure, it delivers reliable performance for control panels, machine rooms, and distributed power systems while supporting clean, compliant installations and scalable capacity growth.

Product Information

Extended Description

Y60M28T75A Eaton: General-Purpose Encapsulated Transformer, EPT, Three-phase, PV: 600V, Taps: 2 at +2.5% FCAN, 4 at -2.5% FCBN, SV: 208Y/120V, 115°C, 75 kVA, Al windings, Frame: 245, Indoor-Outdoor
Product Name
Eaton General purpose encapsulated transformer
Catalog Number
Y60M28T75A
UPC
786680148774
Product Length/Depth
15.68 in
Product Height
32.06 in
Product Width
30.29 in
Product Weight
1275 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Model A
Coil material
Aluminum
Design
EPT
Enclosure
NEMA 3R
Frame
245
Mounting
Floor
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Type
General-Purpose Encapsulated Transformer
Wiring connection
84A
Frequency rating
60 Hz
Kva Rating
75 kVA
Phase
Three-phase
Primary voltage
600 V
Secondary Voltage
208Y/120 V
Temperature rise
115 °C rise
Volt ampere rating
75 kVA
Weathershield
Indoor-Outdoor
Feature: General purpose encapsulated transformer design (EPT) provides a compact, rugged foundation for power distribution. Business Impact: Improves reliability and simplifies installation in crowded plant spaces, reducing commissioning time and on-site wiring errors. Application: Ideal for factory floor panels and centralized distribution hubs with limited cabinet depth.Feature: 75 kVA three-phase rating with 600 V primary and 208Y/120 V secondary. Business Impact: Handles substantial load with reduced voltage drop, enabling smooth operation of motors and controls. Application: Motor feeders and process equipment in manufacturing lines where stable secondary voltages are critical.Feature: Tap settings 2 at +2.5% FCAN and 4 at -2.5% FCBN. Business Impact: Maintains voltage regulation amid supply fluctuations, lowering equipment stress and extending component life. Application: Facilities near variable utility power or long feeder runs where voltage drift is common.Feature: Aluminum windings. Business Impact: Lower material cost and weight with durable performance, facilitating easier handling and procurement. Application: Large installations requiring cost efficiency without compromising thermal performance.Feature: NEMA 3R enclosure with indoor-outdoor Weathershield. Business Impact: Enables safe outdoor installations and compliance with harsh environments, reducing weather-related failure risk. Application: Outdoor substations, exposed control cabinets, and weather-variable plant areas.Feature: 115°C rise rating and floor mounting in frame 245. Business Impact: Supports reliable operation under high-load conditions with a stable base, minimizing thermal shutdown risks. Application: Heavy-load applications in process plants where continuous uptime matters.

Get a Quick Quote for a Eaton Y60M28T75A

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Y60M28T75A? Enquire Now

FAQs

Plan for floor mounting with the 245 frame size and ensure a Level floor or dedicated base. Use the NEMA 3R indoor-outdoor enclosure to protect the unit from dust, moisture, and incidental weather. Verify 84A wiring connections and proper clearances around the transformer to allow for heat dissipation and service access.
The Y60M28T75A is a three-phase 75 kVA transformer with a 600 V primary and 208Y/120 V secondary. It operates at 60 Hz, features aluminum windings, and provides taps at +2.5% FCAN and -2.5% FCBN for voltage regulation. The enclosure supports indoor-outdoor use and has a 115 °C rise rating for high-load applications.
Yes. With a NEMA 3R enclosure, Weathershield for indoor-outdoor service, and UL Listed certification, the Y60M28T75A is well-suited for outdoor installations such as exterior substations, outdoor control panels, and exposed plant areas where reliable voltage transformation is needed.
The transformer carries UL Listed certification, indicating compliance with recognized safety standards. Its rugged enclosure and indoor-outdoor rating support regulatory compliance across many industrial sites, while the aluminum windings and solid construction help meet reliability expectations in regulated environments.
The Eaton Y60M28T75A carries a one-year warranty from the date of installation or 18 months from shipment, whichever comes first. Maintenance needs are typically minimal due to robust encapsulation and durable materials; routine inspections and thermal checks during scheduled maintenance will help sustain performance and maximize lifecycle ROI.