Eaton Z48D29T09CUS6 Hazardous Transformer - UL Listed

Part Number: Z48D29T09CUS6
Manufacturer
Eaton
Part number
Z48D29T09CUS6

Quick Summary

The Eaton Z48D29T09CUS6 Hazardous Transformer delivers safe, reliable power in Class I Division 2 settings for demanding industries. Maintenance costs and downtime in hazardous environments are a constant concern, and equipment must withstand corrosive atmospheres. UL Listed certification, a rugged NEMA 3R enclosure, and Class I Division 2 readiness support safe operation and regulatory compliance. Designed for 50/60 Hz three-phase service with copper windings, it reduces installation risk while enabling scalable power distribution. Businesses gain predictable performance under variable loads thanks to precise tap settings and robust thermal design. Its compact footprint and indoor-outdoor usability streamline installation in tight spaces and harsh environments.

Product Information

Extended Description

Z48D29T09CUS6 Eaton: Eaton Hazardous location encapsulated transformer, class 1 division 2 groups c and d, hazardous location transformer, EPTZ, copper, NEMA 3R, 103H, 60 Hz, three-phase, 480 V, 208 V, 2 at +2.5% FCAN, 2 at -2.5% FCBN, 115 °C rise
Product Name
Eaton Hazardous location encapsulated transformer
Catalog Number
Z48D29T09CUS6
UPC
786680099694
Product Length/Depth
10 in
Product Height
15.94 in
Product Width
21.37 in
Product Weight
234 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Grade 316 stainless steel enclosure
Type
Class 1 Division 2 Groups C and D, Hazardous Location Transformer
Coil material
Copper
Frequency rating
50/60 Hz
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
208 V
Temperature rise
115 °C rise
Design
EPTZ
Enclosure
NEMA 3R
Frame
103H
Tap size
2 at +2.5% FCAN, 2 at -2.5% FCBN
Volt ampere rating
9 kVA
Weathershield
Indoor-Outdoor
Wiring connection
232A
Feature: Class I Division 2 readiness with an encapsulated design. This construction isolates the transformer windings and surfaces from the external environment, minimizing ignition sources in hazardous areas. Business impact: improved safety, regulatory compliance, and lower risk of costly shutdowns in petrochemical or mining sites. Application: ideal for installations in chemical plants, oil refineries, and underground or partially enclosed spaces where accurate voltage support is critical. Feature: Copper windings and copper conductors deliver superior electrical conductivity. Business impact: higher efficiency, reduced copper losses, and better thermal performance under peak loads, which translates to cooler operation and extended transformer life. Application: downstream motor drives, pumps, and instrumentation in manufacturing lines where stable voltage is essential. Feature: Tap settings of 2 at +2.5% FCAN, 2 at -2.5% FCBN. Business impact: precise voltage regulation to accommodate line fluctuations, ensuring connected equipment remains within tolerance and reducing nuisance tripping. Application: matches 480 V to 208 V downstream equipment with precise regulation in variable plant conditions. Feature: NEMA 3R enclosure with Grade 316 stainless steel notes and Weathershield indoor-outdoor rating. Business impact: corrosion resistance and weatherproof protection, enabling outdoor installation without additional housing and lowering total installed cost. Application: outdoor substations, equipment rooms, and outdoor-skid installations. Feature: 50/60 Hz three-phase operation, 9 kVA rating, 480 V primary, 208 V secondary. Business impact: broad compatibility with standard industrial power systems, reduced need for adapters, and scalable power distribution for panels and telematics. Application: distribution transformers in automation cells, machine centers, and process lines. Feature: Frame 103H and 115 °C rise with 232 A wiring connection; Weathershield and 103H frame. Business impact: compact footprint with robust thermal headroom, enabling easier fit in tight spaces and reliable operation during peak demand. Application: retrofits and new installations in compact electrical rooms. Warranty: Eaton Selling Policy 25-000 provides a one-year warranty from installation or eighteen months from shipment, whichever occurs first. This aligns with typical industry expectations for hazardous-location equipment.

Get a Quick Quote for a Eaton Z48D29T09CUS6

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Z48D29T09CUS6? Enquire Now

FAQs

Install in a protected, ventilated area with a Class I Division 2 rating. Ensure the NEMA 3R enclosure is sealed, use copper conductors per 232A wiring, and verify the 10 in x 15.94 in x 21.37 in footprint fits the electrical room. Confirm compliance with UL Listed standards and local codes.
Primary voltage is 480 V, secondary voltage is 208 V, three-phase, at a 9 kVA rating. It operates at 50/60 Hz, making it compatible with common industrial power systems and enabling efficient, scalable distribution to downstream equipment.
Yes. It features a Weathershield indoor-outdoor rating and a NEMA 3R enclosure with a Grade 316 stainless steel option, offering corrosion resistance and weather protection for outdoor substations, shelters, and skid-mounted installations.
The unit is UL Listed, designed for Class I Division 2, and utilizes a corrosion-resistant enclosure (Grade 316 stainless steel option) with a rugged NEMA 3R rating to meet stringent safety and environmental requirements.
Warranty terms follow Eaton Selling Policy 25-000: one year from installation or eighteen months from shipment, whichever occurs first. This includes standard support and access to Eaton technical resources for installation questions and field service.