Eaton Z48E47T03SS4X Hazardous Transformer - Class 1 Div 2

Part Number: Z48E47T03SS4X
Manufacturer
Eaton
Part number
Z48E47T03SS4X

Quick Summary

Hazardous location encapsulated transformer is a rugged power transformer designed for Class 1 Division 2 environments. In hazardous locations, protecting equipment from ignition sources and corrosive exposure without sacrificing uptime is a constant challenge. Designed for Class 1 Division 2 locations (Groups A–D) with a NEMA 4X aluminum enclosure and Weathershield Indoor-Outdoor ratings, it suits rugged plants. With a 3 kVA rating, three-phase 480 V primary and 480Y/277 V secondary, it delivers reliable power while meeting protection and installation requirements. This combination helps you simplify compliance, reduce maintenance costs, and shorten installation time across mission-critical control panels.

Product Information

Extended Description

Z48E47T03SS4X Eaton: Eaton Hazardous location encapsulated transformer, class 1 division 2 groups a b c and d hazardous location transformer, EPTZ, aluminum, NEMA 4X, 60 Hz, 3PH, 480 V, 480Y/277 V, 1 at +5% FCAN 1 at -5% FCBN, 150 °C rise
Product Name
Eaton Hazardous location encapsulated transformer
Catalog Number
Z48E47T03SS4X
UPC
786680080005
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
0.001 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
Contact Manufacturer
Catalog Notes
NEMA 4X Grade 304 stainless steel enclosure.
Type
Class 1 Division 2 Groups A B C & D Hazardous Location Transformer
Coil material
Aluminum
Frequency rating
50/60 Hz
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
480Y/277 V
Temperature rise
150 °C rise
Design
EPTZ
Enclosure
NEMA 4X
Tap size
1 at +5% FCAN, 1 at -5% FCBN
Volt ampere rating
3 kVA
Weathershield
Indoor-Outdoor
Feature: Hazardous location encapsulated design (EPTZ) with an aluminum coil and Class 1 Division 2 rating. This configuration reduces ignition risk in hazardous zones and simplifies field wiring by providing inherent insulation and rugged protection for control circuitry. Applications include chemical plants, oil and gas facilities, and other critical manufacturing lines where safety and reliability are non-negotiable. Feature: NEMA 4X enclosure with Grade 304 stainless steel and Weathershield Indoor-Outdoor design. The rugged housing delivers corrosion resistance for washdowns and outdoor exposure, lowering maintenance frequency and replacement costs. This enclosure configuration is ideal for outdoor control panels and harsh industrial environments where long service life matters. Feature: 3 kVA, three-phase transformer with 480 V primary and 480Y/277 V secondary; 50/60 Hz operation. This specification provides proper power isolation for sensitive control circuits, enabling reliable operation of motor drives and automation cabinets. It supports standard industrial power distribution in manufacturing floors, consolidation of panels, and consistent voltage delivery across loads. Feature: Voltage taps at +5% FCAN and -5% FCBN for voltage regulation. This feature mitigates supply fluctuations, improves voltage tolerance across feeds, and reduces nuisance tripping in fluctuating utility conditions. It supports installations with variable grid quality and long feeder runs, delivering stable performance to critical loads. Feature: Weathershield indoor-outdoor suitability with a 1-year warranty policy (Eaton 25-000). This combination lowers lifecycle costs and simplifies procurement by consolidating safety, compatibility, and support under one supplier. Installers benefit from documented standards and predictable service for industrial automation environments.

Get a Quick Quote for a Eaton Z48E47T03SS4X

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Z48E47T03SS4X? Enquire Now

FAQs

This transformer is designed for Class 1 Division 2 locations (Groups A–D) with a NEMA 4X enclosure, making it suitable for restricted hazardous zones. Plan for proper mounting in protected spaces, ensure correct weatherproofing with the enclosure, and verify routing of primary and secondary conductors to minimize ignition sources while meeting 50/60 Hz power requirements.
The unit is a 3 kVA, three-phase transformer with a 480 V primary and a 480Y/277 V secondary. It operates at 50/60 Hz and includes voltage taps at +5% and -5% FCAN/FCBN for regulation. This combination supports reliable power isolation for automation cabinets and control panels within industrial facilities.
Yes. It features a NEMA 4X enclosure with Weathershield designed for indoor-outdoor use and corrosion resistance. The Grade 304 stainless steel enclosure supports washdown environments and harsh outdoor conditions, reducing maintenance frequency and prolonging service life in demanding installations.
The transformer is rated for Class 1 Division 2 hazardous locations and is housed in a NEMA 4X enclosure with Weathershield for indoor-outdoor use. For additional certifications beyond these ratings, consult Eaton’s specifications or contact the manufacturer for a complete certifications list tailored to your region.
Eaton provides a one-year warranty from installation or eighteen months from shipment, whichever occurs first, under policy 25-000. Support includes standard Eaton product documentation and access to specification sheets and catalogs, helping maintenance teams plan preventive servicing and reducing total cost of ownership.