Eaton Z48G28T15A Hazardous Location Transformer - UL Listed

Part Number: Z48G28T15A
Manufacturer
Eaton
Part number
Z48G28T15A

Quick Summary

The Eaton Hazardous Location Transformer delivers safe, reliable three-phase power for demanding hazardous-area installations. In many plants, operators face downtime and regulatory risk when equipment is not designed for Class I Division 2 environments. Key certifications include UL Listed status, Class 1 Division 2 compliance for Groups C and D, and a NEMA 3R enclosure that supports both indoor and outdoor installation. This encapsulated transformer also supports 480 V primary and 208Y/120 V secondary configurations, helping simplify voltage conversion across your distribution network. By combining rugged construction with proven Eaton design, it reduces maintenance costs, improves protection against ignition sources, and enables faster project approvals, delivering consistent power quality in challenging settings.

Product Information

Extended Description

Z48G28T15A Eaton: Eaton Hazardous location encapsulated transformer, Class 1 Division 2 Groups A, B, C, D Hazardous Location Transformer, Three-phase, PV: 480V, Taps: 2 at -5% FCBN, SV: 208Y/120V, 115°C, 15 kVA, Al windings, Indoor-Outdoor
Product Name
Eaton Hazardous location encapsulated transformer
Catalog Number
Z48G28T15A
UPC
786680006265
Product Length/Depth
10.52 in
Product Height
17.78 in
Product Width
25.18 in
Product Weight
301 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Not Applicable
Certifications
UL Listed
Catalog Notes
Model A
Type
Class 1 Division 2 Groups C and D, Hazardous Location Transformer
Coil material
Aluminum
Frequency rating
50/60 Hz
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
208Y/120 V
Temperature rise
115 °C rise
Design
EPTZ
Enclosure
NEMA 3R
Frame
95H
Tap size
2 at -5% FCBN
Volt ampere rating
15 kVA
Weathershield
Indoor-Outdoor
Wiring connection
70A
Encapsulated hazardous-location design reduces ignition risk and simplifies regulatory compliance in Class I Division 2 zones, enabling safer startup and ongoing operation in oil & gas, chemical processing, and mining environments. This translates to lower risk of costly downtime and easier plant approvals, especially for distributed power on hazardous-site equipment. The 15 kVA three-phase unit with a 480 V primary and 208Y/120 V secondary delivers reliable voltage transformation for common facility distributions, supporting consistent downstream performance on critical equipment and control panels. Two taps at -5% FCBN provide voltage headroom to compensate line drops and maintain performance without costly upstream changes. A rugged NEMA 3R enclosure and the Weathershield indoor-outdoor design offer installation flexibility, whether used indoors, outdoors, or in weather-exposed locations, reducing site-specific engineering. Aluminum windings contribute durability and corrosion resistance, supporting long service life with minimal maintenance in harsh environments. UL Listed certification and Class 1 Division 2 compliance further assure reliability and regulatory acceptance, helping justify project ROI and maintenance planning with confidence.

Get a Quick Quote for a Eaton Z48G28T15A

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Z48G28T15A? Enquire Now

FAQs

Installers should verify the Class I Division 2 rating for the site, mount the unit on a stable, non-combustible surface, and provide adequate enclosure clearance per NEMA 3R guidelines. Wiring should use the 70A connection, with attention to proper heat dissipation and short-circuit protection. The 480V to 208Y/120V outputs require correct circuit protection and voltage regulation during commissioning.
The transformer is a three-phase device rated at 15 kVA with a 480 V primary and a 208Y/120 V secondary. It operates at 50/60 Hz and uses aluminum windings. It features two taps at -5% FCBN for voltage adjustment and a 70A wiring connection. The enclosure is designed for indoor-outdoor use with a NEMA 3R rating.
Yes. Designed for Class I Division 2 hazardous locations (Groups C and D), this encapsulated transformer reduces ignition risk and simplifies regulatory compliance in oil & gas, chemical processing, and other high-risk environments, while providing robust voltage conversion from 480 V to 208Y/120 V for downstream equipment.
The Z48G28T15A is UL Listed and supports hazardous-location requirements Class I Division 2 (Groups C and D). It features a NEMA 3R enclosure suitable for indoor-outdoor installations, ensuring safe operation across varied environmental conditions and helping streamline site approvals and maintenance planning.
The encapsulated design and rugged construction reduce maintenance frequency and downtime in harsh environments. The warranty covers one year from installation or eighteen months from shipment, whichever occurs first, providing a clear baseline for cost of ownership and service planning.