Eaton Z48G47T45 Hazardous Location Transformer - UL Listed

Part Number: Z48G47T45
Manufacturer
Eaton
Part number
Z48G47T45

Quick Summary

Eaton Z48G47T45 hazardous location transformer provides safe power conversion for Class 1 Division 2 industrial environments. In many plants, inconsistent supply, moisture, and corrosive atmospheres create downtime and risk to equipment and personnel. This unit is UL Listed with a rugged NEMA 3R enclosure and Class 1 Division 2 compliance, delivering reliable operation in indoor-outdoor spaces. With a 45 kVA rating, aluminum windings and a 115°C rise, it maintains performance under load while reducing cooling demands. Its 480 V primary and 480Y/277 V secondary configuration fits standard industrial power distributions, helping engineers simplify procurement and reduce integration risk. Designed for long-term reliability, the transformer supports maintenance cycles and helps ensure predictable uptime in critical facilities.

Product Information

Extended Description

Z48G47T45 Eaton: Class 1 Division 2 Groups C and D, Hazardous Location Transformer, EPTZ, 3PH, PV: 480V, Taps: 2 at -5% FCBN, SV: 480Y/277V, 115°C, 45 kVA, Al windings, Frame: 244H, Indoor-Outdoor
Product Name
Eaton Hazardous location encapsulated transformer
Catalog Number
Z48G47T45
UPC
786680072529
Product Length/Depth
12.76 in
Product Height
26.58 in
Product Width
25.15 in
Product Weight
788 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Type
Class 1 Division 2 Groups C and D, Hazardous Location Transformer
Coil material
Aluminum
Frequency rating
50/60 Hz
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
480Y/277 V
Temperature rise
115 °C rise
Design
EPTZ
Enclosure
NEMA 3R
Frame
244H
Tap size
2 at -5% FCBN
Volt ampere rating
45 kVA
Weathershield
Indoor-Outdoor
Wiring connection
66A
Feature: Class 1 Division 2 hazardous location design. Business Impact: Enables safe operation in atmospheres with C and D groups, reducing risk of ignition and improving regulatory compliance. Application: Chemical plants, refineries, and heavy manufacturing where explosive atmospheres are possible. Feature: 45 kVA three-phase transformer. Business Impact: Provides ample headroom for critical loads with efficient heat management, lowering energy losses and improving overall system reliability. Application: Main feeders and motor starting in hazardous zones. Feature: Primary 480 V and secondary 480Y/277 V, 50/60 Hz. Business Impact: Simplifies integration with common industrial power systems and downstream equipment matching. Application: Control panels and distribution centers in hazardous environments. Feature: Tap size 2 at -5% FCBN. Business Impact: Voltage compensation for long feeders or voltage drop scenarios, protecting equipment and extending service life. Application: Remote installations with variable supply. Feature: Aluminum windings and 115°C rise. Business Impact: Lightweight conduction with robust thermal performance, enabling compact installation and sustained performance under peak loads. Application: Dense electrical rooms and outdoor installations. Feature: NEMA 3R enclosure and indoor-outdoor rating. Business Impact: Weather-resistant protection that reduces enclosure maintenance and increases uptime. Application: Outdoor equipment yards, damp environments, and mixed indoor-outdoor spaces. Feature: 66A wiring connection and 244H frame. Business Impact: Facilitates straightforward mounting and compatibility with standard distribution cabinets. Application: Facility retrofit projects and new builds. Feature: 788 lb weight and rugged construction. Business Impact: Durability with secure, vibration-resistant installation in demanding facilities. Application: Industrial sites with forklift access and constrained spaces. Feature: UL Listed and warranty coverage. Business Impact: Compliance assurance and risk mitigation with predictable after-sales support. Application: Procurement and service planning in regulated industries.

Get a Quick Quote for a Eaton Z48G47T45

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Z48G47T45? Enquire Now

FAQs

For Class 1 Division 2 installations, plan for proper clearances around the unit, secure mounting on a rigid base compatible with the 244H frame, and ensure the enclosure is protected from direct impacts. Verify ambient conditions stay within enclosure ratings and follow Eaton installation guidelines to maintain UL Listed status.
The two taps at -5% FCBN allow voltage adjustment to compensate for line drop or transformer coordination with downstream loads. Use the taps when feeder distances or supply fluctuations cause under-voltage at secondary equipment; this helps maintain voltage within tolerance and reduces motor stalling and overheating.
Yes. The Z48G47T45 provides a 480 V primary and a 480Y/277 V secondary in a 3-phase arrangement, designed for hazardous locations. Its EPTZ design and UL Listed certification, along with Class 1 Division 2 compliance, make it appropriate for powering lighting, controls, and small motors in those environments.
This transformer is UL Listed and designed for Class 1 Division 2 hazardous locations (Groups C and D). It features a NEMA 3R enclosure suitable for indoor-outdoor use, and the product is manufactured to meet rugged industrial standards for hazardous environments, ensuring safer operation and regulatory alignment.
The Z48G47T45 carries Eaton’s warranty policy of one year from installation or eighteen months from shipment, whichever occurs first. Routine maintenance should focus on inspecting connections, torque for field tapping, checking insulation integrity, and confirming enclosure seals remain intact for continued UL Listed and NEMA 3R compliance.