Eaton Z48N11S05SS Encapsulated Transformer - UL Listed

Part Number: Z48N11S05SS
Manufacturer
Eaton
Part number
Z48N11S05SS

Quick Summary

Z48N11S05SS encapsulated transformer is a reliable power isolation device for hazardous Class 1 Division 2 environments. In real-world installations, engineers often contend with enclosure integrity, moisture ingress, and warranty coverage in tough sites. UL Listed certification paired with hazardous location ratings, plus a rugged NEMA 3R enclosure and EPZ design, help ensure safety and uptime. This Eaton transformer supports 5 kVA with a 480 V primary and 120/240 V secondary, delivering dependable power for industrial controls and outdoor equipment, while mitigating risk and simplifying compliance for your power distribution needs.

Product Information

Extended Description

Z48N11S05SS Eaton: Eaton Class 1 Division 2 Groups C and D, Hazardous Location Transformer, EPZ, Single-phase, PV: 480V, Taps: None, SV: 120/240V, 115°C, 5 kVA, Al windings, Frame: 177H, Indoor-Outdoor.
Product Name
Eaton Hazardous location encapsulated transformer
Catalog Number
Z48N11S05SS
UPC
786680006364
Product Length/Depth
9.89 in
Product Height
16.53 in
Product Width
15.54 in
Product Weight
131 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Grade 304 stainless steel enclosure
Type
Class 1 Division 2 Groups C and D, Hazardous Location Transformer
Coil material
Aluminum
Frequency rating
50/60 Hz
Phase
Single-phase
Primary voltage
480 V
Secondary Voltage
120/240 V
Temperature rise
115 °C rise
Design
EPZ
Enclosure
NEMA 3R
Frame
177H
Tap size
None
Volt ampere rating
5 kVA
Weathershield
Indoor-Outdoor
Wiring connection
524H
Feature: Class 1 Division 2, Groups C and D hazardous location rating with EPZ design → Business Impact: Enables safe operation in demanding hazardous environments, reducing risk of ignition and non-compliance penalties → Application: Chemical plants, oil and gas facilities, and remote process skids. Feature: Encapsulated construction with Grade 304 stainless enclosure (catalog note) → Business Impact: Superior enclosure integrity and corrosion resistance in challenging climates → Application: Outdoor control panels and moisture-prone areas, delivering long service life with less maintenance. Feature: Aluminum windings, 5 kVA VA rating, 480 V primary, 120/240 V secondary → Business Impact: Efficient power isolation and reliable step-down for controls and instrumentation, improving overall system efficiency and safety → Application: Industrial automation cabinets, motor control centers, and panel boards. Feature: 50/60 Hz single-phase design, 115°C rise, EPZ designation, frame 177H → Business Impact: Broad compatibility with standard plant frequencies and predictable thermal performance, simplifying spec and installation → Application: Control panels in mixed-utility facilities and process lines. Feature: NEMA 3R enclosure, indoor-outdoor capability, Weathershield specification → Business Impact: Flexible installation options, including outdoor locations, with protection against rain, dust, and temperature swings → Application: Outdoor substations, instrument enclosures, and hazardous-location installations with harsh environmental exposure. Feature: Wiring connection 524H and documented catalog notes → Business Impact: Streamlined installation and serviceability, reducing labor time and wiring errors → Application: Field integration and cabinet retrofits with standardized wiring practices. Protection and reliability considerations are supported by a robust 1-year warranty (or 18 months from shipment, whichever comes first), and UL Listed certification, which together reinforce regulatory compliance and warranty coverage while delivering measurable uptime.

Get a Quick Quote for a Eaton Z48N11S05SS

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Z48N11S05SS? Enquire Now

FAQs

This transformer is designed for hazardous Class 1 Division 2 environments with EPZ construction and a NEMA 3R enclosure. Plan for indoor-outdoor mounting, ensure adequate clearance and cooling, and use the 524H wiring connection for field installations. The unit weighs 131 lb, fits a 177H frame, and benefits from stainless enclosure compatibility in harsh sites.
It is rated for Class 1 Division 2 Groups C and D, with aluminum windings and a 5 kVA rating. The 480 V primary and 120/240 V secondary provide reliable isolation and step-down for controls. With UL Listed certification and a 115°C temperature rise, it maintains performance under elevated ambient conditions common in hazardous settings.
Yes. The Z48N11S05SS features an indoor-outdoor Weathershield design and a Grade 304 stainless steel enclosure noted in catalog data, supporting both indoor panels and outdoor installations. Its NEMA 3R enclosure enhances protection from rain and dust, while the EPZ configuration keeps critical components sealed and accessible for service.
The primary certification is UL Listed, indicating compliance with recognized safety standards. It is rated for Class 1 Division 2 hazardous locations (Groups C and D) with an EPZ design, and it employs a corrosion-resistant enclosure suitable for challenging environments, providing assurance for regulatory and safety requirements in industrial facilities.
With a rugged encapsulated design, aluminum windings, and a stainless enclosure, maintenance is typically minimal for routine inspections. The 5 kVA rating and 480 V to 120/240 V output support durable, reliable power for control panels, reducing downtime and replacement costs. A one-year warranty (or 18 months from shipment) adds financial protection during early operation.