Norgren M/58411/02 Bellows suction cup - G1/2
Part Number: M/58411/02
Quick Summary
Bellows suction cup enables level-compensated gripping for precision pick-and-place tasks in automation lines. This design mitigates grip failures when surfaces vary in height, reducing rework and part damage. Typical industry certifications to consider include CE compliance for safe machinery integration, IP ratings for ingress protection in harsh environments, and SIL compatibility in safety-controlled systems. By combining a robust aluminium body with silicone elastomer, this cup delivers reliable, repeatable performance in vacuum handling across diverse applications, while staying compatible with Norgren’s vacuum ecosystem. The result is lower lifecycle costs and improved throughput in packaging, electronics assembly, and automotive component handling.
Product Information
Extended Description
M/58411/02 Norgren: Bellows cups ideal where level compensation is required
Medium
Vacuum
Operating Temperature
-30 ... 200 °C, -22 ... 392 °F
Port Size
G1/2
Diameter
110 mm
Materials - Body
Aluminium
Materials - Elastomers
Silicone
Range
M/58400
Series
Norgren Vacuum
Brand
IMI Norgren
Feature → Business Impact → Application: Vacuum medium enables clean, reliable suction across a broad range of parts, reducing grip slippage and improving placement accuracy in high-speed lines. Application: suitable for delicate parts like glass, PCB carriers, and small metallic components where level compensation is critical. Feature → Aluminium body provides strength with reduced weight, boosting system efficiency and reducing wear on mounting hardware. Application: ideal for compact automation cells and retrofit projects where space is constrained. Feature → Silicone elastomer offers stable gripping with chemical and temperature resistance, extending seal life and maintaining grip reliability. Application: performs consistently from -30 to 200 °C, supporting demanding environments in automotive and electronics assembly. Feature → G1/2 port size ensures compatibility with common vacuum manifolds and fittings, simplifying integration. Application: quick installation on standard pneumatic/vacuum trains and robotic grippers. Feature → 110 mm diameter gripping surface delivers broad contact area, improving grip stability for varying part geometries. Application: reduces regrip events in packaging and assembly lines. Feature → Range M/58400 and Norgren Vacuum Series alignment guarantees ecosystem compatibility, enabling straightforward maintenance and spares availability. Application: supports scalable deployments in multi-line operations. Objection: concerns about elastomer wear in high-speed cycles are addressed by selecting high-temperature silicone variants and scheduling periodic seal inspections, which minimizes unexpected downtime and extends service life.
Get a Quick Quote for a Norgren M/58411/02
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Norgren M/58411/02?
Enquire Now
FAQs
The M/58411/02 uses a standard G1/2 port that fits most vacuum manifolds and quick-connect fittings. Ensure the mounting face is clean and parallel to the part surface to avoid tilt grip. Align the 110 mm suction surface with the target area, then tighten mounting hardware to the recommended torque. For retrofit projects, verify compatibility with your existing vacuum train and confirm the bore match with your connectors to prevent leaks.
Operating temperature spans from -30 to 200 °C (-22 to 392 °F), enabling use in high-temperature processes without elastomer degradation. The aluminium body provides structural strength with light weight, while the silicone elastomer offers good grip and chemical resistance. This combination supports long service life in demanding environments and maintains reliable performance across a broad range of applications.
Yes. The bellows design accommodates height variations and minor tilts, reducing the risk of part damage during pick-and-place. The silicone elastomer provides a compliant yet secure grip on delicate items like electronics components and fragile packaging. For high-throughput lines, pairing with proper dwell time and vacuum settings ensures gentle handling without compromising cycle speed.
Industry best practices for automation components emphasize CE compliance for machinery safety and interoperability. Depending on configuration, IP ratings may apply to enclosure protection in harsh environments, and SIL compatibility is considered when the component interfaces with safety-related controls. Always verify the specific variant datasheet for exact certifications and compliance notes relevant to your installation.
Regular inspection of the silicone elastomer seals for wear and tears is recommended, with replacement scheduled based on cycle count and part sensitivity. The aluminium body is durable, supporting longer intervals between maintenance. ROI benefits come from reduced grip failures, lower rework rates, and higher line uptime due to more reliable handling in packaging, electronics, and automotive assemblies.