Norgren M/80/IOL/15C/CC Inline flow sensor - IO-Link
Part Number: M/80/IOL/15C/CC
Quick Summary
Inline flow sensor measures compressed air flow, pressure, temperature, and total consumption for factory pneumatic systems. This tool helps engineers move beyond simple readings by delivering real-time data that supports proactive maintenance and process optimization. In practice, teams often struggle with slow data access, inconsistent readings, and difficulty tracing usage across multiple lines. IO-Link readiness and a digital data stream simplify integration with existing controllers and MES, enabling remote diagnostics and faster issue isolation. CE-compliant environments, robust enclosure considerations, and typical IP-rated deployment are common expectations for this class of device. For modern facilities, the combination of IO-Link interoperability and compact German-engineered hardware translates into improved traceability, reduced downtime, and lower operating costs, with the option to expand monitoring using compatible IO-Link masters and accessories.
Product Information
Extended Description
M/80/IOL/15C/CC Norgren: Measures compressed air flow rate, pressure, temperature and total volumetric flow consumption | Digital Transmission of parameters via IO-link | Integrated TFT display for easy identification | High accuracy, repeatability and measurement dynamics
Medium
Compressed air, Nitrogen
Operating Temperature
-10 ... 60 °C, 14 ... 140 °F
Operating Pressure
-1 ... 16 bar, -14.5 ... 232 psi
Thread
1/2" NPT
Flow
1250 l/m, 44.15 scfm
Country of Origin
Germany
Series
M/80
Brand
IMI Norgren
NC-125FS-125MS-5
Connector cable, 5 pin, A-coded, M12, M12, 5m
NC-125FS-125MS-2
Connector cable, 5 pin, A-coded, M12, M12, 2m
NC-125FS-125MS-1
Connector cable, 5 pin, A-coded, M12, M12, 1m
NC-125FS-00000-5
Connector cable, Open end, 5 pin, A-coded, M12, 5m
NC-125FS-125MS-A
Connector cable, 5 pin, A-coded, M12, M12, 0.6m
840014-51KIT
Excelon Plus Quikclamp
840014-52KIT
Excelon Plus Quikclamp with Bracket Assembly
840015-11KIT
Excelon Plus Port Adaptors G1/2
NC-ME-4A4B-12DLA
IO-Link master, EtherNet/IP interface
NC-HB-8A5F-12A0A
IO-Link I/O module, Standard
NC-HA-8A5F-12AAA
IO-Link I/O module, Auxillary power
NC-MP-4A4B-12DLA
IO-Link master, PROFINET interface
Feature: IO-Link digital transmission and integrated TFT display. Business Impact: Real-time, easily identifiable readings on the panel reduce setup time and enable quick diagnostics during shifts. Application: Ideal for monitoring pneumatic circuits in automated cells. Feature: Measures flow rate up to 1250 L/m, pressure from -1 to 16 bar, and temperature -10 to 60 °C. Business Impact: Precise, repeatable measurements improve process tuning, energy efficiency and regulatory compliance in compressed air systems. Application: Suitable for high-demand factory environments where air usage must be quantified. Feature: DN 15 connection with 1/2" NPT thread and versatile mounting options (Excelon Plus Quikclamp variants). Business Impact: Easy installation and reliable fixation cut commissioning time and vibration-induced drift. Application: Fits standard pneumatic manifolds and compact control cabinets. Feature: Connector options including 5 m, 2 m, 1 m, and open-end cables with M12, A-coded, 5-pin configuration. Business Impact: Flexible integration with IO-Link masters and control networks reduces wiring complexity and service interruptions. Application: Supports scalable deployment across multiple lines. Feature: IO-Link compatibility with IO-Link masters and IO-Link I/O modules. Business Impact: Enables remote data access, diagnostics, and firmware updates without on-site visits. Application: Suited for energy optimization, predictive maintenance, and Industry 4.0 monitoring. Feature: German engineering heritage and robust construction. Business Impact: Reliability in harsh industrial environments lowers total cost of ownership and extends service intervals. Application: Appropriate for automotive, packaging, and process automation facilities that require durable sensing solutions.
Get a Quick Quote for a Norgren M/80/IOL/15C/CC
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Norgren M/80/IOL/15C/CC?
Enquire Now
FAQs
This inline sensor offers a DN 15 connection and a 1/2" NPT thread, with multiple connector cable options (5 m, 2 m, 1 m, and 5 m open-end variants) using M12, A-coded, 5-pin interfaces. It integrates with standard IO-Link masters and IO-Link I/O modules, simplifying fieldbus and control system compatibility while reducing wiring complexity.
Key specs include flow up to 1250 L/m (44.15 scfm), operating pressure range of -1 to 16 bar (-14.5 to 232 psi), and operating temperature from -10 to 60 °C (14 to 140 °F). Medium support includes compressed air and nitrogen, making it suitable for broad industrial use where precise air flow data is required.
Yes. The product detail lists nitrogen as a compatible medium alongside compressed air, enabling accurate flow, pressure, and temperature measurements in mixed gas environments. Ensure enclosure protection and system compatibility with your process chemistry and safety requirements when selecting materials and fitment.
IO-Link compatibility aligns with standard industrial networking requirements. For EU deployments, CE-like conformity is typically expected, and installation should consider enclosure integrity and environmental protection per your plant’s IP ratings. SIL considerations are scoped at the system level for safety-critical applications; consult your safety engineer to verify applicability.
Real-time data from IO-Link, TFT identification, and robust installation options reduce commissioning time and enable rapid fault isolation, lowering downtime. The sensor enables precise air usage tracking, supporting energy efficiency initiatives and predictive maintenance programs, which collectively translate into lower operating costs and better asset utilization.