Norgren M/80/IOL/15T/CC Inline flow sensor - IO-Link
Part Number: M/80/IOL/15T/CC
Quick Summary
Norgren M/80/IOL/15T/CC Inline flow sensor enables precise compressed air flow measurement for pneumatic systems. Manual monitoring often yields drift and delays, making production scheduling and maintenance more challenging. The device supports IO-Link digital transmission and features an integrated TFT display, aiding rapid data interpretation and status identification. With a DN 15 connection and a robust -1 to 16 bar operating range, it integrates seamlessly into existing lines, delivering reliable data for efficiency, traceability, and predictive maintenance. Designed for industrial environments, it pairs with mounting options and IO-Link masters to streamline installation and ensure long-term reliability.
Product Information
Extended Description
M/80/IOL/15T/CC Norgren: Measures compressed air flow rate, pressure, temperature and total volumetric flow consumption | Digital Transmission of parameters via IO-link | Integrated TFT display for easy identification | High accuracy, repeatability and measurement dynamics
Medium
Compressed air, Nitrogen
Operating Temperature
-10 ... 60 °C, 14 ... 140 °F
Operating Pressure
-1 ... 16 bar, -14.5 ... 232 psi
Thread
R1/2
Flow
1250 l/m, 44.15 scfm
Country of Origin
Germany
Series
M/80
Brand
IMI Norgren
NC-125FS-125MS-5
Connector cable, 5 pin, A-coded, M12, M12, 5m
NC-125FS-125MS-2
Connector cable, 5 pin, A-coded, M12, M12, 2m
NC-125FS-125MS-1
Connector cable, 5 pin, A-coded, M12, M12, 1m
NC-125FS-00000-5
Connector cable, Open end, 5 pin, A-coded, M12, 5m
NC-125FS-125MS-A
Connector cable, 5 pin, A-coded, M12, M12, 0.6m
840014-51KIT
Excelon Plus Quikclamp
840014-52KIT
Excelon Plus Quikclamp with Bracket Assembly
840015-11KIT
Excelon Plus Port Adaptors G1/2
NC-ME-4A4B-12DLA
IO-Link master, EtherNet/IP interface
NC-HB-8A5F-12A0A
IO-Link I/O module, Standard
NC-HA-8A5F-12AAA
IO-Link I/O module, Auxillary power
NC-MP-4A4B-12DLA
IO-Link master, PROFINET interface
The IO-Link enabled M80 sensor provides digital transmission of process parameters, which reduces wiring complexity and minimizes data loss, directly improving control system integration and diagnostics. This translates to measurable business impact: faster commissioning, easier remote monitoring, and improved traceability across production cells. In practical applications such as packaging lines or automated manufacturing, the 1250 l/m flow capability combined with -1 to 16 bar operating pressure ensures accurate shedding of compressed air consumption while preserving system responsiveness. The integrated TFT display offers on-site visibility, enabling quick verification without additional handheld tools, while the DN 15 connection and R1/2 thread simplify retrofits and new installations alike. Connector options from 1 to 5 meters support flexible system topology, and mounting kits like Excelon Plus Quikclamp speed up installation and serviceability. IO-Link masters and IO-Link I/O modules listed in the IO-Link section enable scalable networked instrumentation and easier maintenance planning. Overall, you gain improved energy efficiency, reduced downtime, and safer, more compliant pneumatic systems.
Get a Quick Quote for a Norgren M/80/IOL/15T/CC
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Norgren M/80/IOL/15T/CC?
Enquire Now
FAQs
Begin by confirming the R1/2 thread and DN 15 connection. Use the Excelon Plus Quikclamp mounting kit for fast, vibration-resistant attachment and connect the M12 IO-Link cables (5 m, 2 m, or 1 m options available) to the IO-Link master. Ensure the sensor is powered and addressed in the IO-Link network via the master (EtherNet/IP or PROFINET interfaces are supported by compatible modules). After mechanical installation, verify electrical connections and use the TFT display for quick status checks.
The sensor measures flow rate (up to 1250 l/m), pressure (-1 to 16 bar), temperature (-10 to 60 °C), and total volumetric flow. It transmits data digitally via IO-Link for seamless integration with control systems. With an inline DN 15 connection and a 1250 l/m maximum flow, it supports accurate monitoring in typical pneumatic circuits and packaging lines.
Yes. The product is designed for compressed air and nitrogen media, offering robust performance in typical packaging and automation environments. Its IO-Link interface provides reliable data exchange to MES or PLCs, enabling real-time monitoring and analytics for nitrogen-assisted processes or standard air systems while maintaining high measurement dynamics.
The data sheet references standard industrial sensor practices and IO-Link compatibility. Verify CE, IP ratings, and SIL-related considerations in the official datasheet and installation guide. When deploying in regulated environments, confirm the exact compliance documentation with your procurement policy and ensure the IO-Link configuration aligns with your control system's safety and quality requirements.
IO-Link data access and the TFT display enable proactive maintenance and faster fault isolation, reducing downtime. Simplified wiring and modular IO-Link cabling reduce installation costs and changeover times. In practice, you gain improved energy efficiency from precise air usage, better process control, and a shorter time to value for automation projects, contributing to a favorable return on investment over system lifetimes.